Radiation effects on scientific complementary metal-oxide-semiconductor detectors for x-ray astronomy: II. Total ionizing dose irradiation

被引:1
|
作者
Chen, Mengxi [1 ]
Ling, Zhixing [1 ,2 ]
Liu, Mingjun [1 ,2 ]
Wu, Qinyu [1 ,2 ]
Zhang, Chen [1 ,2 ]
Liu, Jiaqiang [3 ]
Zhang, Zhenlong [2 ,3 ]
Yuan, Weimin [1 ,2 ]
Zhang, Shuang-Nan [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Natl Astron Observ, Beijing, Peoples R China
[2] Univ Chinese Acad Sci, Sch Astron & Space Sci, Beijing, Peoples R China
[3] Chinese Acad Sci, Natl Space Sci Ctr, Beijing, Peoples R China
[4] Chinese Acad Sci, Inst High Energy Phys, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
x-ray detector; CMOS detector; gamma radiation; detector performance; CCD; PROTON;
D O I
10.1117/1.JATIS.10.2.026001
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
. Complementary metal-oxide-semiconductor (CMOS) detectors are a competitive choice for current and upcoming astronomical missions. To understand the performance variations of CMOS detectors in the space environment, we investigate the total ionizing dose effects on custom-made large-format X-ray CMOS detectors. Three CMOS detector samples were irradiated with a <mml:mmultiscripts>Co60</mml:mmultiscripts> source with a total dose of 70 and 105 krad. We test and compare the performance of these detectors before and after irradiation. After irradiation, the dark current increases by roughly 20 similar to 100 times, and the readout noise increases from 3e- to 6e-. The bias level at 50 ms integration time decreases by 13 to 18 digital number (DN) at -30 degrees C. The energy resolution increases from similar to 150 to similar to 170eV at 4.5 keV at -30 degrees C. The conversion gain of the detectors varies for <2% after the irradiation. Furthermore, there are about 50 pixels in which bias at 50 ms has changed by more than 20 DN after the exposure to the radiation and about 30 to 140 pixels in which the readout noise has increased by over 20e- at -30<degrees>C at 50 ms integration time. These results demonstrate that the performances of large-format CMOS detectors do not suffer significant degeneration in space environment.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Total Ionizing Dose effects in DDR3 SDRAMs under Co-60 and X-ray irradiation
    Kohler, P.
    Pouget, V
    Saigne, F.
    Boch, J.
    Maraine, T.
    Wang, P. X.
    Vassal, M-C
    2018 18TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS (RADECS), 2018, : 20 - 26
  • [22] Note: A disposable x-ray camera based on mass produced complementary metal-oxide-semiconductor sensors and single-board computers
    Hoidn, Oliver R.
    Seidler, Gerald T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (08):
  • [23] Total ionizing dose effects on the SOI pixel sensor for X-ray astronomical use
    Mori, Koji
    Nishioka, Yusuke
    Takeda, Ayaki
    Takebayashi, Nobuaki
    Takenaka, Ryota
    Sakakura, Seina
    Yokoyama, Shoma
    Fukuda, Kohei
    Yukumoto, Masataka
    Hida, Takahiro
    Tsuru, Takeshi G.
    Tanaka, Takaaki
    Matsumura, Hideaki
    Hayashi, Hideki
    Kohmura, Takayoshi
    Nakashima, Shinya
    Arai, Yasuo
    Kurachi, Ikuo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 924 (473-479): : 473 - 479
  • [24] Comparison of complementary metal oxide semiconductor and charge-coupled device intraoral X-ray detectors using subjective image quality
    Kitagawa, H
    Scheetz, JP
    Farman, AG
    DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (06) : 408 - 411
  • [25] The sixth generation: introduction of two new high fill factor complementary metal oxide semiconductor (or SuperCMOS) intraoral X-ray detectors
    Inglese, JM
    Farman, TT
    Farman, AG
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1152 - 1156
  • [26] EFFECTS OF GAMMA-RAY IRRADIATION ON CUBIC SILICON-CARBIDE METAL-OXIDE-SEMICONDUCTOR STRUCTURE
    YOSHIKAWA, M
    ITOH, H
    MORITA, Y
    NASHIYAMA, I
    MISAWA, S
    OKUMURA, H
    YOSHIDA, S
    JOURNAL OF APPLIED PHYSICS, 1991, 70 (03) : 1309 - 1312
  • [27] Total-Ionizing-Dose Effects on a Graphene X-Ray Detector Laser-Scribed From Graphene Oxide
    Deng, Ning-Qin
    Liao, Wen-Jun
    Hu, Jing
    Wang, Peng
    Xu, Meng-Xuan
    Zhang, Hai-Nan
    Wang, Pan
    Liang, Chun-Dong
    Tian, He
    Chen, Liang
    Ouyang, Xiao-Ping
    Yang, Yi
    Ren, Tian-Ling
    Zhang, En Xia
    Fleetwood, Daniel M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (01) : 473 - 477
  • [28] The total ionizing dose effects of X-ray irradiation on graphene/Si Schottky diodes with a HfO2 insertion layer
    Xu, Yannan
    Bi, Jinshun
    Li, Yudong
    Xi, Kai
    Fan, Linjie
    Liu, Ming
    Sandip, M.
    Luo, Li
    MICROELECTRONICS RELIABILITY, 2019, 100
  • [29] The dependence of the total intensity of the x-ray radiation on the current strength in the x-ray tube. II. Announcement.
    Nasledow, D
    Scharawsky, P
    PHYSIKALISCHE ZEITSCHRIFT, 1927, 28 : 625 - 632
  • [30] MOS-TRANSISTOR RADIATION DETECTORS AND X-RAY DOSE-ENHANCEMENT EFFECTS
    POSEY, LD
    WROBEL, TF
    EVANS, DC
    BEEZHOLD, W
    KELLY, JG
    MACCALLUM, CJ
    COPPAGE, FN
    LUERA, TF
    LORENCE, LJ
    SMITH, AJ