Determining the influence of soil layers on apparent soil resistivity through small-scale laboratory experiments

被引:2
作者
Kundu, Soumitra Kumar [1 ]
Dey, Ashim Kanti [2 ]
机构
[1] Natl Inst Technol Silchar, Dept Civil Engn, Silchar 743122, Assam, India
[2] Natl Inst Technol Silchar, Dept Civil Engn, Silchar, India
关键词
Electric resistivity; soil box; layers; clay content; heterogeneity; ELECTRICAL-RESISTIVITY; TOMOGRAPHY; CIRCULATION; COMPACTION;
D O I
10.1080/19386362.2024.2395713
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Electrical resistivity (ER) method, non-destructive approach determining subsurface anomalies by leveraging electrical properties. In-situ ER is popular owing to its quick, reliable and continuous subsurface data, although heterogeneity across horizontal and vertical orientation is less explored. In this regard, present study tends to understand this effect by carrying out small-scale laboratory ER tests focusing on how varying vertical soil layer positions impact resistivity. Two distinct soil types with varying resistivity were arranged in both perpendicular and parallel direction to current flow, where low and high resistive layers were placed adjacent to one another. Results derived from study indicated that placement of low resistive soil before high resistive one leads to 37.58 % reduction in resistivity. Furthermore, parallel alignment resulted in 9.89 % decrease compared to perpendicular layering. Thus, these findings tends to highlight significance of layering in influencing resistivity values and underscoring the complexity of electrical resistivity testing.
引用
收藏
页码:445 / 457
页数:13
相关论文
共 55 条
[1]   Interpretation of soil grain size effect on electrical resistivity method [J].
Abd Malik, A. K. ;
Madun, A. ;
Abu Talib, M. K. ;
Wahab, N. ;
Dan, M. F. Md .
PHYSICS AND CHEMISTRY OF THE EARTH, 2023, 129
[2]   The electrical resistivity log as an aid in determining some reservoir characteristics [J].
Archie, GE .
TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1942, 146 :54-61
[3]  
Bawallah M. A., 2021, INDONESIAN J EARTH S, V1, P84, DOI [https://doi.org/10.52562/injoes.v1i2.253, DOI 10.52562/INJOES.V1I2.253]
[4]  
Bello R., 2017, SCI AFRICANA, V16
[5]   Spatial characterization of leachate plume using electrical resistivity tomography in a landfill composed of old and new cells (Belfort, France) [J].
Bichet, Vincent ;
Grisey, Elise ;
Aleya, Lotfi .
ENGINEERING GEOLOGY, 2016, 211 :61-73
[6]   STUDY OF DRIVEN GROUND RODS AND 4 POINT SOIL RESISTIVITY TESTS [J].
BLATTNER, CJ .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (08) :2837-2850
[7]   ANALYSIS OF SOIL RESISTIVITY TEST METHODS IN 2-LAYER EARTH [J].
BLATTNER, CJ .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (12) :3603-3608
[8]  
Bryson Lindsey., 2005, GEOTECHNICAL SPECIAL, P1, DOI DOI 10.1061/40779(158)10
[9]  
CAMPBELL RB, 1948, SOIL SCI SOC AM PRO, V13, P66
[10]   Noninvasive monitoring of DNAPL migration through a saturated porous medium using electrical impedance tomography [J].
Chambers, JE ;
Loke, MH ;
Ogilvy, RD ;
Meldrum, PI .
JOURNAL OF CONTAMINANT HYDROLOGY, 2004, 68 (1-2) :1-22