Tungsten-Based Contrast Agent for Photon-Counting Detector CT Angiography in Calcified Coronaries

被引:1
作者
Sartoretti, Thomas [1 ,2 ,3 ]
McDermott, Michael C. [2 ,3 ,4 ]
Stammen, Lion [2 ,3 ]
Martens, Bibi [2 ,3 ]
Moser, Lukas J. [1 ,3 ]
Jost, Gregor [4 ]
Pietsch, Hubertus [4 ]
Gutjahr, Ralf [5 ]
Nowak, Tristan [5 ]
Schmidt, Bernhard [5 ]
Flohr, Thomas G. [2 ,5 ]
Wildberger, Joachim E. [2 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Diagnost & Intervent Radiol, Zurich, Switzerland
[2] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, Maastricht, Netherlands
[3] Maastricht Univ, CARIM Sch Cardiovasc Dis, Maastricht, Netherlands
[4] Bayer AG, Berlin, Germany
[5] Siemens Healthineers AG, Computed Tomog Div, Forchheim, Germany
关键词
tungsten; iodine; photon-counting CT; dual-energy CT; virtual monoenergetic imaging; MEDIA;
D O I
10.1097/RLI.0000000000001073
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. Materials and Methods: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. Results: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions (R-2 >= 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. Conclusions: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as-in distinction to iodine-both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.
引用
收藏
页码:677 / 683
页数:7
相关论文
共 50 条
  • [31] Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology
    Leng, Shuai
    Bruesewitz, Michael
    Tao, Shengzhen
    Rajendran, Kishore
    Halaweish, Ahmed F.
    Campeau, Norbert G.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    RADIOGRAPHICS, 2019, 39 (03) : 729 - 743
  • [32] The potential of photon-counting CT for quantitative contrast-enhanced imaging in radiotherapy
    Simard, Mikael
    Lapointe, Andreanne
    Lalonde, Arthur
    Bahig, Houda
    Bouchard, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (11)
  • [33] Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm Assessment Using a Cardiac Motion Phantom
    Allmendinger, Thomas
    Nowak, Tristan
    Flohr, Thomas
    Klotz, Ernst
    Hagenauer, Junia
    Alkadhi, Hatem
    Schmidt, Bernhard
    INVESTIGATIVE RADIOLOGY, 2022, 57 (06) : 399 - 405
  • [34] Feasibility study of photon-counting CT for material identification based on YSO/SiPM detector: A proof of concept
    Zhang, Du
    Wu, Bin
    Xi, Daoming
    Chen, Rui
    Xiao, Peng
    Xie, Qingguo
    MEDICAL PHYSICS, 2024, 51 (11) : 8151 - 8167
  • [35] Diagnostic performance of Photon-counting CT angiography in peripheral artery disease compared to DSA as gold standard
    Ghibes, Patrick
    Hagen, Florian
    Weissinger, Matthias
    Wrazidlo, Robin
    Nikolaou, Konstantin
    Levitin, Abraham
    Kirksey, Levester
    Artzner, Christoph
    Groezinger, Gerd
    Partovi, Sasan
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 182
  • [36] Material Decomposition in Photon-Counting CT: A Deep Learning Approach Driven by Detector Physics and ASIC Modeling
    Yu, Xiaopeng
    Wu, Qianyu
    Qin, Wenhui
    Zhong, Tao
    Su, Mengqing
    Ma, Jinglu
    Zhang, Yikun
    Ji, Xu
    Quan, Guotao
    Chen, Yang
    Du, Yanfeng
    Lai, Xiaochun
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2024, PT VII, 2024, 15007 : 457 - 466
  • [37] Spectral metal artifact reduction after posterior spinal fixation in photon-counting detector CT datasets
    Popp, Daniel
    Sinzinger, Andrea X.
    Decker, Josua A.
    Braun, Franziska
    Bette, Stefanie
    Risch, Franka
    Haerting, Mark
    Garthe, Tarik
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 165
  • [38] Calcium scoring on coronary computed angiography tomography with photon-counting detector technology: Predictors of performance
    Vecsey-Nagy, M.
    Varga-Szemes, A.
    Emrich, T.
    Zsarnoczay, E.
    Nagy, N.
    Fink, N.
    Schmidt, B.
    Nowak, T.
    Kissf, M.
    Vattay, B.
    Boussoussou, M.
    Kolossvary, M.
    Kubovje, A.
    Merkely, B.
    Maurovich-Horvat, P.
    Szilveszter, B.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2023, 17 (05) : 328 - 335
  • [39] Dual-contrast agent photon-counting computed tomography of the heart: initial experience
    Symons, Rolf
    Cork, Tyler E.
    Lakshmanan, Manu N.
    Evers, Robert
    Davies-Venn, Cynthia
    Rice, Kelly A.
    Thomas, Marvin L.
    Liu, Chia-Ying
    Kappler, Steffen
    Ulzheimer, Stefan
    Sandfort, Veit
    Bluemke, David A.
    Pourmorteza, Amir
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (08) : 1253 - 1261
  • [40] Dual-contrast agent photon-counting computed tomography of the heart: initial experience
    Rolf Symons
    Tyler E. Cork
    Manu N. Lakshmanan
    Robert Evers
    Cynthia Davies-Venn
    Kelly A. Rice
    Marvin L. Thomas
    Chia-Ying Liu
    Steffen Kappler
    Stefan Ulzheimer
    Veit Sandfort
    David A. Bluemke
    Amir Pourmorteza
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1253 - 1261