Endoluminal rescue of false lumen graft deployment in TEVAR for type B aortic dissection: a case report and literature review

被引:0
作者
Zhu, Hong Jiang [1 ]
Yan, Feng [1 ]
Zhao, Peng Peng [1 ]
机构
[1] Zhangjiajie Peoples Hosp, Dept Vasc Intervent Surg, Zhangjiajie, Hunan, Peoples R China
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2024年 / 11卷
关键词
aortic; aortic dissection; TEVAR; stent graft misdeployment; case report;
D O I
10.3389/fcvm.2024.1461511
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Thoracic endovascular aortic repair (TEVAR) has increasingly become the preferred surgical intervention for Stanford type B aortic dissection (TBAD). The primary objective of this procedure is to seal the primary entry tear to promote positive aortic remodeling. However, the increased use of TEVAR has also led to a rise in surgical complications. Among these, the accidental deployment of the stent into the false lumen is a rare but serious complication that can result in aortic false lumen rupture and inadequate perfusion of abdominal organs.Case summary This case report described a 78-year-old man who presented to our hospital with sudden onset chest and back pain and was subsequently diagnosed with TBAD via aortic CTA. As conventional medical therapy failed to alleviate his chest pain, the patient underwent TEVAR. During the procedure, a complication arose when the distal end of the endograft was mistakenly deployed into the false lumen, leading to insufficient perfusion of the abdominal organs. Recognizing this issue intraoperatively, an additional endograft was promptly inserted at the distal end to reroute blood flow back to the true lumen of the aorta, thereby restoring visceral perfusion. Post-intervention, the patient's chest pain improved, and he was successfully discharged from the hospital.Conclusion Accidental deployment of a endograft into the false lumen during TEVAR is a rare but serious complication. Intraoperative angiography plays a crucial role in rapidly and accurately identifying this issue by detecting insufficient perfusion of abdominal organs. The use of intravascular ultrasound may help reduce the incidence of this complication. Endovascular repair is an effective emergency strategy to quickly redirect blood flow back to the true lumen, making it the preferred method for managing such emergencies.
引用
收藏
页数:5
相关论文
共 14 条
  • [1] Spinal cord protection in open and endovascular approaches to thoracoabdominal aortic aneurysms
    Amabile, Andrea
    Lewis, Erin
    Costa, Victor
    Tadros, Rami O.
    Han, Daniel K.
    Di Luozzo, Gabriele
    [J]. VASCULAR, 2023, 31 (05) : 874 - 883
  • [2] Acute aortic dissection
    Carrel, Thierry
    Sundt, Thoralf M.
    von Kodolitsch, Yskert
    Czerny, Martin
    [J]. LANCET, 2023, 401 (10378) : 773 - 788
  • [3] Risk factors for target vessel endoleaks after physician-modified fenestrated or branched endovascular aortic arch repair: A retrospective study
    Chen, Zhipeng
    Fu, Dongsheng
    Liu, Cheng
    Jin, Yi
    Pan, Chaohui
    Mamateli, Subinur
    Lv, Xiaochen
    Qiao, Tong
    Liu, Zhao
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [4] Stent-Graft Migration Post-Endovascular Repair of Thoracic Aorta: A Retrospective Cohort Study
    Deshpande, Amit Ajit
    Pandey, Niraj Nirmal
    Shaw, Manish
    Kumar, Sanjeev
    Jagia, Priya
    Sharma, Sanjiv
    Choudhary, Shiv
    [J]. INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2022, 32 (03) : 324 - 331
  • [5] Endovascular graft deployment in the false lumen of type B dissection
    Follis, Fabrizio
    Filippone, Gianfranco
    Stabile, Amerigo
    Montalbano, Giuseppe
    Floriano, Maria
    Finazzo, Mario
    Follis, Marco
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 10 (04) : 597 - 599
  • [6] Incorrect frozen elephant trunk deployment into the false lumen of a patient with complicated type B acute dissection
    Fujii, Masahiko
    Watanabe, Hiroyuki
    Otsu, Masayoshi
    Sugahara, Yuta
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 55 (06) : 1222 - 1224
  • [7] Endovascular rescue after inadvertent false lumen stent graft implantation
    Han, Sukgu M.
    Gasper, Warren J.
    Chuter, Timothy A. M.
    [J]. JOURNAL OF VASCULAR SURGERY, 2016, 63 (02) : 518 - 522
  • [8] Aortic Endograft Infection: Diagnosis and Management
    Kim, Young-Wook
    [J]. VASCULAR SPECIALIST INTERNATIONAL, 2023, 39
  • [9] Value of intravascular ultrasound for endovascular stent-graft placement in aortic dissection and aneurysm
    Koschyk, DH
    Meinertz, T
    Hofmann, T
    Kodolitsch, YV
    Dieckmann, C
    Wolf, W
    Knap, M
    Kiraly, Z
    Steffen, W
    Beythien, C
    Lund, G
    Rehders, T
    Nienaber, CA
    [J]. JOURNAL OF CARDIAC SURGERY, 2003, 18 (05) : 471 - 477
  • [10] Successful endoluminal rescue of an endovascular graft unintentionally deployed in the false lumen of Stanford type B aortic dissection
    Ma, Xiang
    Fu, Weiguo
    Ma, Yi-Tong
    Karmacharya, Ujit
    Zhao, Jun
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (03) : E41 - E45