Deep learning image reconstruction for low-kiloelectron volt virtual monoenergetic images in abdominal dual-energy CT: medium strength provides higher lesion conspicuity

被引:1
作者
Zhong, Jingyu [1 ]
Hu, Yangfan [1 ]
Xing, Yue [1 ]
Wang, Lingyun [2 ]
Li, Jianying [3 ]
Lu, Wei [4 ]
Shi, Xiaomeng [5 ]
Ding, Defang [1 ]
Ge, Xiang [1 ]
Zhang, Huan [2 ]
Yao, Weiwu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Tongren Hosp, Sch Med, Dept Imaging, Shanghai 200336, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Dept Radiol, Shanghai, Peoples R China
[3] GE Healthcare, Computed Tomog Res Ctr, Beijing, Peoples R China
[4] GE Healthcare, Computed Tomog Res Ctr, Shanghai, Peoples R China
[5] Imperial Coll London, Dept Mat, London, England
基金
中国国家自然科学基金;
关键词
Multidetector computed tomography; deep learning; image reconstruction; contrast enhancement; QUALITY;
D O I
10.1177/02841851241262765
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background The best settings of deep learning image reconstruction (DLIR) algorithm for abdominal low-kiloelectron volt (keV) virtual monoenergetic imaging (VMI) have not been determined. Purpose To determine the optimal settings of the DLIR algorithm for abdominal low-keV VMI. Material and Methods The portal-venous phase computed tomography (CT) scans of 109 participants with 152 lesions were reconstructed into four image series: VMI at 50 keV using adaptive statistical iterative reconstruction (Asir-V) at 50% blending (AV-50); and VMI at 40 keV using AV-50 and DLIR at medium (DLIR-M) and high strength (DLIR-H). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of nine anatomical sites were calculated. Noise power spectrum (NPS) using homogenous region of liver, and edge rise slope (ERS) at five edges were measured. Five radiologists rated image quality and diagnostic acceptability, and evaluated the lesion conspicuity. Results The SNR and CNR values, and noise and noise peak in NPS measurements, were significantly lower in DLIR images than AV-50 images in all anatomical sites (all P < 0.001). The ERS values were significantly higher in 40-keV images than 50-keV images at all edges (all P < 0.001). The differences of the peak and average spatial frequency among the four reconstruction algorithms were significant but relatively small. The 40-keV images were rated higher with DLIR-M than DLIR-H for diagnostic acceptance (P < 0.001) and lesion conspicuity (P = 0.010). Conclusion DLIR provides lower noise, higher sharpness, and more natural texture to allow 40 keV to be a new standard for routine VMI reconstruction for the abdomen and DLIR-M gains higher diagnostic acceptance and lesion conspicuity rating than DLIR-H.
引用
收藏
页码:1133 / 1146
页数:14
相关论文
共 47 条
  • [41] Phantom task-based image quality assessment of three generations of rapid kV-switching dual-energy CT systems on virtual monoenergetic images
    Greffier, Joel
    Viry, Anais
    Barbotteau, Yves
    Frandon, Julien
    Loisy, Maeliss
    de Oliveira, Fabien
    Beregi, Jean Paul
    Dabli, Djamel
    [J]. MEDICAL PHYSICS, 2022, 49 (04) : 2233 - 2244
  • [42] Deep-learning image-reconstruction algorithm for dual-energy CT angiography with reduced iodine dose: preliminary results
    Noda, Y.
    Nakamura, F.
    Kawamura, T.
    Kawai, N.
    Kaga, T.
    Miyoshi, T.
    Kato, H.
    Hyodo, F.
    Matsuo, M.
    [J]. CLINICAL RADIOLOGY, 2022, 77 (02) : E138 - E146
  • [43] Reducing contrast medium dose with low photon energy images in renal dual-energy spectral CT angiography and adaptive statistical iterative reconstruction (ASIR)
    Zhang, Xirong
    Chen, Jing
    Yu, Nan
    Ren, Zhanli
    Tian, Qian
    Tian, Xin
    Jia, Yongjun
    He, Taiping
    Guo, Changyi
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1120)
  • [44] Improved overall image quality in low-dose dual-energy computed tomography enterography using deep-learning image reconstruction
    Lin, Xu
    Gao, Yankun
    Zhu, Chao
    Song, Jian
    Liu, Ling
    Li, Jianying
    Wu, Xingwang
    [J]. ABDOMINAL RADIOLOGY, 2024, 49 (09) : 2979 - 2987
  • [45] Radiation and iodine dose reduced thoraco-abdominopelvic dual-energy CT at 40 keV reconstructed with deep learning image reconstruction
    Noda, Yoshifumi
    Kawai, Nobuyuki
    Kawamura, Tomotaka
    Kobori, Akikazu
    Miyase, Rena
    Iwashima, Ken
    Kaga, Tetsuro
    Miyoshi, Toshiharu
    Hyodo, Fuminori
    Kato, Hiroki
    Matsuo, Masayuki
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1134)
  • [46] Single-Subject Deep-Learning Image Reconstruction With a Neural Optimization Transfer Algorithm for PET-Enabled Dual-Energy CT Imaging
    Li, Siqi
    Zhu, Yansong
    Spencer, Benjamin A.
    Wang, Guobao
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2024, 33 : 4075 - 4089
  • [47] Virtual unenhanced imaging of the liver derived from 160-mm rapid-switching dual-energy CT (rsDECT): Comparison of the accuracy of attenuation values and solid liver lesion conspicuity with native unenhanced images
    Lacroix, Maxime
    Mule, Sebastien
    Herin, Edouard
    Pigneur, Frederic
    Richard, Philippe
    Zegai, Benhalima
    Baranes, Laurence
    Djabbari, Marjan
    Brunetti, Francesco
    De'Angelis, Nicola
    Laurent, Alexis
    Tacher, Vania
    Kobeiter, Hicham
    Luciani, Alain
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2020, 133