Effect of aging on dimensional accuracy and color stability of CAD-CAM milled and 3D-printed denture base resins: a comparative in-vitro study

被引:6
作者
Gad, Marwa A. [1 ]
Abdelhamid, Ahmed M. [1 ]
ElSamahy, Mahmoud [1 ]
Abolgheit, Salma [2 ]
Hanno, Kenda I. [1 ]
机构
[1] Alexandria Univ, Fac Dent, Dept Prosthodont, Alexandria, Egypt
[2] Alexandria Univ, Fac Dent, Dept Dent Biomat, Alexandria, Egypt
关键词
CAD-CAM; 3D-printed; Dimensional accuracy; Color stability; Thermocycling; Cleanser; SURFACE-ROUGHNESS; ADAPTATION;
D O I
10.1186/s12903-024-04848-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background There is a lack of studies comparing the dimensional accuracy and color stability of denture base resins made using computer-aided design and computer-aided manufacturing (CAD-CAM) milling, 3-dimensional (3D) printing, and conventional denture processing techniques. This makes it challenging to determine the best method to fabricate complete dentures. The objective of this in vitro investigation was to assess and contrast the color stability and dimensional accuracy of denture base resins that were 3D printed and CAD-CAM milled, both before and after aging by thermocycling using digital surface matching technology and a benchtop laser scanner without using a spray, to optimize adaptation of the denture base and cast to minimize any imperfections and to evaluate the impact of the denture cleansing solution on the stability of color. Methods Evaluation of the dimensional accuracy (n = 27) was completed on a sectional maxillary stone cast using a digital 3D-surface matching software before and after 5000 thermocycles. A spectrophotometer was used to measure the color change (triangle E00) of all disc specimens (N = 54) before and after 500 thermocycles and immersion in denture cleansing solution for 30 cycles (3 min each) daily for 6 days. The Kruskal Wallis test, Dunn's post hoc test, Tukey's test with Bonferroni adjustment, one sample t test and independent t test were used to statistically analyze the data (alpha < 0.05). Results Thermocycling decreased the dimensional accuracy of the heat polymerized group at all 5 locations and the 3D-printed group at locations 1, 3 and 5 (P > .05), while it had no significant difference on the CAD-CAM milled group at all locations (P < .05). The color change (triangle E00) was lowest in the CAD-CAM milled group, moderate in the heat-polymerized group and highest in the 3D-printed group. After immersion in denture cleanser, the color change (triangle E00) was significantly higher in the 3 groups compared with after thermocycling (P > .001). Conclusions CAD-CAM milled resins had the highest dimensional accuracy and the best color stability, conventional heat polymerized acrylic resins showed moderate change in dimensional accuracy and color stability, while the 3D- printed resin had the lowest dimensional accuracy and color stability after aging by thermocycling.
引用
收藏
页数:14
相关论文
共 66 条
[1]  
Abou-Obaid A.I., 2018, Int. J. Contemp. Res. Rev, V9, P20442, DOI [10.15520/ijcrr/2018/9/02/421, DOI 10.15520/IJCRR/2018/9/02/421]
[2]  
Abu-Bakr N, 2000, J Esthet Dent, V12, P258, DOI 10.1111/j.1708-8240.2000.tb00232.x
[3]   Power brushing and chemical denture cleansers induced color changes of pre-polymerized CAD/CAM denture acrylic resins [J].
Alfouzan, Afnan F. ;
AlNouwaisar, Alhanouf N. ;
AlAzzam, Njood F. ;
Al-Otaibi, Hanan N. ;
Labban, Nawaf ;
Alswaidan, Mashaal H. ;
Al Taweel, Sara M. ;
Alshehri, Huda A. .
MATERIALS RESEARCH EXPRESS, 2021, 8 (08)
[4]   3D printed complete removable dental prostheses: a narrative review [J].
Anadioti, Eva ;
Musharbash, Leen ;
Blatz, Markus B. ;
Papavasiliou, George ;
Kamposiora, Phophi .
BMC ORAL HEALTH, 2020, 20 (01)
[5]   Color stability of heat-polymerized and autopolymerized soft denture liners [J].
Anil, N ;
Hekimoglu, C ;
Sahin, S .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (04) :481-484
[6]  
[Anonymous], 2013, ISO-20795-1, P6
[7]  
[Anonymous], 2016, ISO/TR-28642:2016(E)
[8]  
[Anonymous], 1994, ISO/TR-11405, P2
[9]   Effect of thermocycling on the surface properties of CAD-CAM denture base materials after different surface treatments [J].
Atalay, Sevda ;
Cakmak, Guelce ;
Fonseca, Manrique ;
Schimmel, Martin ;
Yilmaz, Burak .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 121
[10]   Effect of staining and denture cleaning on color stability of differently polymerized denture base acrylic resins [J].
Ayaz, E. A. ;
Ustun, S. .
NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2020, 23 (03) :304-309