Analysis of 3D positioning error for multipath indoor VLC system

被引:1
作者
Rangappa, Karibasappa [1 ]
Kumar, Ajit [2 ]
机构
[1] Govt Engn Coll Ramanagara, Dept Elect & Commun Engn, Ramanagara, Karnataka, India
[2] Presidency Univ, Sch Engn Elect & Commun, Bengaluru 560064, Karnataka, India
关键词
BER; bit rate; indoor positioning; multipath; RSS; VLC;
D O I
10.1002/dac.5937
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A comparative analysis of 3D positioning error for two different configurations using different layouts of visible light communication (VLC) systems is presented in this paper. The Received Signal Strength (RSS) has been implemented for indoor localization systems using Line-of-Sight (LoS) and diffused reflection signals. The room size for configuration-1 is 5 m x 5 m x 3 m, and the distance between adjacent LEDs is 2.5 m, 2.00 m, and 1.5 m for cases-1, case-2, and case-3, respectively, whereas the room size for configuration-2 is 7 m x 7 m x 5 m, and the separation between the LEDs is 3.5 m, 3 m, and 2.5 m for their respective cases. Through investigation, it has been shown that when only LS signal is considered, the separation between LEDs may not be an issue because positioning error changes by a very small amount as the separation between LEDs changes. The results show that as the distance between adjacent LEDs decreases, the received signal strength for LoS and L-R1 signals increases. However, positioning error and BER rise, while the bit rate falls. Furthermore, the positioning error Vs receiver plane height for all three cases in configuration-1 is the same up to a height of 2.89 m, whereas the positioning error in configuration-2 is the same up to 4.4 m for all cases. The positioning error for case-1 decreases as the height in configuration-1 exceeds 2.89 m. Similarly, after reaching a height of 4.4 m for case-2, the positioning error in configuration-2 decreases. The LoS positioning error versus semi angle phi 1/2$$ {\varphi}_{1/2} $$ of the LED as well as the FOV of the receiver has been simulated for different positions of the receiver in configuration-1. The investigation shows that the minimum positioning error is achieved at phi 1/2$$ {\varphi}_{1/2} $$ and FOV equal to 66.660 for all the positions of the receiver in the room. Thus, before configuring a practical indoor VLC geometrical model, proper VLC configurations such as LED separation, FOV of the receiver, semi angle of LED, and receiver height should be chosen based on the room dimensions. This paper presents a comparative analysis of 3D positioning error in two VLC system configurations using RSS for indoor localization. Findings indicate that positioning error is minimally affected by LED separation with only LoS signals. Reduced LED distances enhance signal strength but increase positioning error and BER while lowering the bit rate. Optimal configurations, including LED separation, receiver FOV, semi-angle, and height, are critical for minimizing positioning error based on room dimensions. image
引用
收藏
页数:26
相关论文
共 50 条
  • [31] VLC-Based Positioning System for an Indoor Environment Using an Image Sensor and an Accelerometer Sensor
    Phat Huynh
    Yoo, Myungsik
    SENSORS, 2016, 16 (06)
  • [32] Error Mitigation in Optical Camera Communication Based Indoor Positioning System
    Shahjalal, Md
    Hasan, Moh Khalid
    Hossan, Md Tanvir
    Chowdhury, Mostafa Zaman
    Jang, Yeong Min
    2018 TENTH INTERNATIONAL CONFERENCE ON UBIQUITOUS AND FUTURE NETWORKS (ICUFN 2018), 2018, : 100 - 103
  • [33] SDR Based Indoor Beacon Localization Using 3D Probabilistic Multipath Exploitation and Deep Learning
    Hall, Donald L.
    Narayanan, Ram M.
    Jenkins, David M.
    ELECTRONICS, 2019, 8 (11)
  • [34] Precise Positioning in 3D Using Spherical Co-ordinates as Applied to Indoor Localization
    Pillalamarri, Balakrishna
    Murthy, Garimella Rama
    2015 GLOBAL CONFERENCE ON COMMUNICATION TECHNOLOGIES (GCCT), 2015, : 8 - 11
  • [35] An Enhanced 3D Positioning Scheme Exploiting Adaptive Pulse Selection for Indoor LOS Environments
    Youngok Kim
    Nammoon Kim
    Wireless Personal Communications, 2014, 77 : 2537 - 2548
  • [36] An Enhanced 3D Positioning Scheme Exploiting Adaptive Pulse Selection for Indoor LOS Environments
    Kim, Youngok
    Kim, Nammoon
    WIRELESS PERSONAL COMMUNICATIONS, 2014, 77 (04) : 2537 - 2548
  • [37] Investigation of a 3D undersea positioning system using electromagnetic waves
    Kato, Ryosuke
    Takahashi, Masaharu
    Ishii, Nozomu
    Chen, Qiang
    Yoshida, Hiroshi
    2019 23RD INTERNATIONAL CONFERENCE ON APPLIED ELECTROMAGNETICS AND COMMUNICATIONS (ICECOM 2019), 2019,
  • [38] Indoor Positioning With Adaptive Wavelet Denoise Enhancement and Trend Surface Analysis Based Multipath Map
    Ma, Difeng
    Zhao, Kun
    Zheng, Zhengqi
    Yu, Chao
    Wang, Yuhang
    Yao, Yongjun
    IEEE SENSORS JOURNAL, 2022, 22 (15) : 15191 - 15198
  • [39] Analysis of Positioning Accuracy corresponding to the number of BLE beacons in Indoor Positioning System
    Ji, Myungin
    Kim, Jooyoung
    Jeon, Juil
    Cho, Youngsu
    2015 17TH INTERNATIONAL CONFERENCE ON ADVANCED COMMUNICATION TECHNOLOGY (ICACT), 2015, : 92 - 95
  • [40] Magnetic Field Analysis for Distance Measurement in 3D Positioning Applications
    Pasku, Valter
    De Angelis, Alessio
    De Angelis, Guido
    Moschitta, Antonio
    Carbone, Paolo
    2016 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, 2016, : 736 - 741