Improving Raman stand-off distance for the detection of chemical warfare agents

被引:0
|
作者
Davies, Samantha [1 ]
Curtis, Kelly [2 ]
Mcewan, Ken [2 ]
机构
[1] Dstl Porton Down, Chem Biol & Radiat Div, Salisbury SP4 0JQ, Wilts, England
[2] Dstl Porton Down, Cyber & Informat Syst Div, Salisbury SP4 0JQ, Wilts, England
来源
CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES, CBRNE SENSING XXV | 2024年 / 13056卷
关键词
Raman spectroscopy; chemical warfare agents; stand-off detection;
D O I
10.1117/12.3014374
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Operating a chemical detector system at a stand-off distance from a hazard is advantageous. By increasing the distance between the detector and the hazard, the risk of contamination decreases, whilst increasing personnel safety. The aim of this work is to develop an optical bench mounted system for presumptive identification of toxic chemical simulants at a stand-off distance. Unlike commercially available instruments, the Dstl system is not a light tight unit, but instead offers a platform in which different optical sub-components can be tested in an attempt to optimise the overall sensitivity of the system. By operating in a pulsed mode, not only is detector noise reduced but also the background radiation due to laboratory light. To test its performance, the Dstl Raman system was assessed at a stand-off distance of 2 m and collected spectra from Raman standard materials. Additional work was conducted with the Dstl Raman system to collect spectra from toxic chemicals associated with chemical warfare agents (CWAs). Indicative comparisons were made against data collected on commercially available systems, in order to identify future development for the Dstl system. Overall, this research piece aimed to exploit the powerful discriminatory nature of the Raman technique whilst demonstrating it under room lights and at useful stand-off distances. The Dstl stand-off Raman system performed well and provided clean spectra for the CWA simulant study. However all the tests reported here were measured on bulk samples and further work is needed to determine how the system performs against samples deposited as thin layers on realistic substrates
引用
收藏
页数:15
相关论文
共 50 条
  • [41] CWA Stand-off detection, a new figure-of-merit: The Field Surface Scanning Rate
    Bernascolle, Philippe F.
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XIV, 2013, 8710
  • [42] Field Trials of DIAL Stand-off Detection Using CO2 Tunable Laser
    Simko, Michal
    Valovsky, Martin
    ELECTRO-OPTICAL REMOTE SENSING XVI, 2022, 12272
  • [43] Stand-off detection of ethanol by laser absorption spectrometry with interference-based internal standard
    Liu X.
    Du Z.
    Wang X.
    Yuan L.
    Huang L.
    Li Y.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2022, 51 (12):
  • [44] Stand-off detection of aerosols using mid-infrared backscattering Fourier transform spectroscopy
    Maidment, L.
    Zhang, Z.
    Bowditch, M. D.
    Howle, C. R.
    Reid, D. T.
    OPTICS AND PHOTONICS FOR COUNTERTERRORISM, CRIME FIGHTING, AND DEFENCE XII, 2016, 9995
  • [45] Stand-off detection of explosives of suicide bombers by means of open-path FTIR spectroscopy
    Weber, Konradin
    Fischer, Christian
    van Haren, Guenther
    Krause, Horst
    Bunte, Gudrun
    Schweikert, Wenka
    Haerdle, Thomas
    STAND-OFF DETECTION OF SUICIDE BOMBERS AND MOBILE SUBJECTS, 2006, : 135 - +
  • [46] The contactless/contact type detection technologies of Chemical Warfare Agents
    Lama, Sanjeeb
    Park, Hyewon
    Kim, Jinuk
    Kim, Jihyun
    Seo, Byung Yeol
    Ramesh, Sivalingam
    Kim, Joo-Hyung
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2021, 2021, 11591
  • [47] On-site detection method for biological and chemical warfare agents
    Seto, Yasuo
    BUNSEKI KAGAKU, 2006, 55 (12) : 891 - 906
  • [48] Analytical and on-site detection methods for chemical warfare agents
    Seto, Yasuo
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2006, 126 (12): : 1279 - 1299
  • [49] Stand-off detection of amino acids and nucleic bases using a compact instrument as a tool for search for life
    Acosta-Maeda, Tayro E.
    Misra, Anupam K.
    Muzangwa, Lloyd G.
    Berlanga, Genesis
    Sharma, Shiv K.
    Abedin, M. Nurul
    LIDAR REMOTE SENSING FOR ENVIRONMENTAL MONITORING XVI, 2018, 10779
  • [50] Detection performance of Drager safety gas detection tube for chemical warfare agents
    Takayama, Yasuo
    Sekioka, Ryoji
    Sekiguchi, Hiroshi
    Maruko, Hisashi
    Ohmori, Takeshi
    Seto, Yasuo
    BUNSEKI KAGAKU, 2007, 56 (05) : 355 - 362