Determination of tetrodotoxin in human plasma and urine using online MCX SPE column cleanup coupled with liquid chromatography-tandem mass spectrometry

被引:0
作者
Fang, Li [1 ]
Qiu, Fengmei [2 ]
Wang, Yuchao [1 ]
机构
[1] Zhoushan Municipal Ctr Dis Control & Prevent, Key Lab Hlth Risk Factors Seafood Zhejiang Prov, Zhoushan 316021, Peoples R China
[2] Putuo Ctr Dis Control & Prevent, Zhoushan 316100, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2024年 / 1244卷
关键词
Tetrodotoxin; Poisoning; Plasma; Urine; Online SPE cleanup; SOLID-PHASE EXTRACTION; LC-MS/MS; IDENTIFICATION; SERUM; TOXICITY; TOXIN; CONFIRMATION; VALIDATION; BLOOD;
D O I
10.1016/j.jchromb.2024.124174
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An efficient technique for quantitative analysis of tetrodotoxin (TTX) in human plasma and urine has been developed, which combines liquid chromatography-tandem mass spectrometry (LC-MS/MS) with online MCX solid phase extraction (SPE) cleanup. Sample preparation, including extraction with acetonitrile containing 0.5 % acetate acid, centrifugation, and filtration, was followed by online SPE cleanup. The whole run-time was less than 15 min, including online cleanup, chromatographic separation, and re-equilibration of the online SPE- LC-MS/MS system. The parameters of sample extraction, purification, separation, and detection were optimized. The matrix-matched internal standard calibration standard curves with linear regression coefficients larger than 0.9990 were established for quantification. The LOD and LOQ for this approach were determined to be 0.1 ng/ mL and 0.3 ng/mL, respectively. The recoveries for varied concentrations of TTX in human plasma and urine were 84.9-104.2 % and 89.2-109.6 %, respectively. The matrix effects of TTX in human plasma and urine matrices were 85.5 % and 74.3 %, respectively, and both the inter- and intra-day precision values were less than 9.5%. This analytical method was successfully employed for detecting TTX in biological samples from a poisoned patient who accidentally ingested the nassarius glans.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Development and validation of a high-throughput online solid phase extraction - Liquid chromatography - Tandem mass spectrometry method for the detection of tetrodotoxin in human urine
    Coleman, Rebecca
    Lemire, Sharon W.
    Bragg, William
    Garrett, Alaine
    Ojeda-Torres, Geovannie
    Hamelin, Elizabeth
    Johnson, Rudolph C.
    Thomas, Jerry
    [J]. TOXICON, 2016, 119 : 64 - 71
  • [32] Quantitative determination of peptide drug in human plasma samples at low pg/ml levels using coupled column liquid chromatography-tandem mass spectrometry
    Lovgren, Ulf
    Johansson, Sara
    Jensen, Lasse Skov
    Ekstrom, Carina
    Carlshaf, Alf
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 53 (03) : 537 - 545
  • [33] DETERMINATION OF DIETHYLSTILBESTROL IN HUMAN PLASMA WITH MEASUREMENT UNCERTAINTY ESTIMATION BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Liu, Yi
    Li, Na
    Ma, Liping
    Huang, Lin
    Jing, Shan
    Zhao, Libo
    Feng, Wanyu
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (03) : 353 - 366
  • [34] Determination of albendazole sulfoxide in human plasma by using liquid chromatography-tandem mass spectrometry
    Saraner, Nihal
    Ozkan, Guler Yagmur
    Guney, Berrak
    Alkan, Erkin
    Burul-Bozkurt, Nihan
    Saglam, Onursal
    Fikirdesici, Ezgi
    Yaldirim, Mevlut
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1022 : 1 - 5
  • [35] Simultaneous determination of β-blockers in human plasma using liquid chromatography-tandem mass spectrometry
    Umezawa, Hironobu
    Lee, Xiao-Pen
    Arima, Yoshiko
    Hasegawa, Chika
    Izawa, Hikaru
    Kumazawa, Takeshi
    Sato, Keizo
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 702 - 711
  • [36] Quantitation of tazemetostat in human plasma using liquid chromatography-tandem mass spectrometry
    Orleni, Marco
    Parise, Robert A.
    Holleran, Julianne L.
    Amengual, Jennifer E.
    Feng, Ye
    Synold, Timothy
    Beumer, Jan H.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (07)
  • [37] Liquid chromatography-tandem mass spectrometry for the determination of low-molecular mass aldehydes in human urine
    Eugenia Banos, Clara
    Silva, Manuel
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (7-8): : 653 - 658
  • [38] Liquid chromatography-tandem mass spectrometry measurement of 26 steroid hormones in human serum and plasma samples
    Jia, Yongjuan
    Liu, Xingli
    Xu, Li
    Zhao, Jinbao
    Ni, Junjun
    Zhang, Yuanyuan
    [J]. JOURNAL OF SEPARATION SCIENCE, 2021, 44 (12) : 2358 - 2370
  • [39] Simultaneous determination of metformin and glipizide in human plasma by liquid chromatography-tandem mass spectrometry
    Ding, Cun-Gang
    Zhou, Zhen
    Ge, Qing-Hua
    Zhi, Xiao-Jin
    Ma, Li-Li
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (02) : 132 - 138
  • [40] Determination of henatinib in human plasma and urine by liquid chromatography-tandem mass spectrometry and its pharmacokinetic application
    Qian, Jun
    Wang, Yixuan
    Cao, Junning
    Li, Jin
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 80 : 173 - 179