Polyethylene wear and cup migration of cemented total hip arthroplasty with femoral heads made of oxidized zirconium, steel, or cobalt chromium: a 10-year secondary analysis from a randomized trial using radiostereometry

被引:0
|
作者
Johannessen, Hakon Greve [1 ]
Hallan, Geir [1 ,3 ,4 ]
Kadar, Thomas [2 ]
Fenstad, Anne Marie [3 ]
Lygre, Stein Hakon Lastad [3 ,9 ]
Haugan, Kristin [5 ]
Hol, Paul Johan [1 ,6 ]
Badawy, Mona [4 ]
Jonsson, Benedikt [7 ]
Indrekvam, Kari [1 ,4 ]
Aamodt, Arild [8 ]
Furnes, Ove [1 ,3 ]
机构
[1] Univ Bergen, Fac Med, Dept Clin Med, Bergen, Norway
[2] Haukeland Hosp, Dept Phys Med & Rehabil, Bergen, Norway
[3] Haukeland Hosp, Dept Orthopaed Surg, Norwegian Arthroplasty Register, Bergen, Norway
[4] Haukeland Hosp, Coastal Hosp Hagavik, Dept Orthopaed Surg, Bergen, Norway
[5] St Olavs Univ Hosp, Dept Orthopaed Surg, Trondheim, Norway
[6] Haukeland Hosp, Dept Orthopaed Surg, Biomatlab, Bergen, Norway
[7] Landshospitali Univ Hosp, Reykjavik, Iceland
[8] Lovisenberg Diakonal Hosp, Dept Orthopaed Surg, Oslo, Norway
[9] Haukeland Hosp, Dept Occupat Med, Bergen, Norway
关键词
CROSS-LINKED POLYETHYLENE; MOLECULAR-WEIGHT POLYETHYLENE; ACETABULAR CUPS; OSTEOLYSIS; STERILIZATION; RSA;
D O I
10.2340/17453674.2024.41945
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - We aimed to evaluate polyethylene (PE) wear, cup migration, and clinical outcome over 10 years in total hip arthroplasties (THA) using different articulations. Methods - This is a secondary analysis of 150 patients randomized into 5 groups, using different articulations: Charnley/Charnley Ogee for steel and conventional polyethylene (CPE), or Spectron EF/Reflection with either CPE or highly cross linked polyethylene (XLPE) cups, paired with heads made of either cobalt-chromium (CoCr) or oxidized zirconium (OxZr). All cups were cemented. Patients underwent repeated radiostereometric analysis (RSA) measurements for up to 10 years to assess wear and migration. Clinical outcome was assessed using Harris Hip Score (HHS). Results - After 10 years, the XLPE cups demonstrated low wear rates: 0.08 mm (95% confidence interval [CI] -0.11 to 0.26 mm) with CoCr heads and 0.06 mm (CI -0.14 to 0.26 mm) with OxZr heads, with a mean difference of 0.01 mm (CI -0.26 to 0.29 mm). In contrast, CPE cups exhibited significantly more wear: 1.35 mm (CI 1.16 to 1.55 mm) with CoCr heads and 1.68 mm (CI 1.44 to 1.92 mm) with OxZr heads, with a mean difference of 0.33 mm (CI 0.02 to 0.64 mm). The Charnley/Ogee group (CPE) showed PE wear of 0.34 mm (CI 0.12 to 0.56 mm). The CPE groups with OxZr and CoCr heads had 0.67 mm (CI 0.38 to 0.96 mm) and 0.35 mm (CI 0.09 to 0.61 mm) greater proximal migration respectively than the corresponding XLPE groups. HHS was similar across all groups. Conclusion - We found no significant advantage of OxZr over CoCr heads in reducing wear or migration. XLPE demonstrated a major reduction in wear as well as a reduction in cup migration compared with CPE. Charnley performed better than the other CPE cups in terms of PE wear and cup migration. No differences in clinical outcome were found.
引用
收藏
页码:578 / 585
页数:8
相关论文
共 10 条
  • [1] Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty A MULTICENTRE RANDOMISED CONTROLLED TRIAL
    Jassim, S. S.
    Patel, S.
    Wardle, N.
    Tahmassebi, J.
    Middleton, R.
    Shardlow, D. L.
    Stephen, A.
    Hutchinson, J.
    Haddad, F. S.
    BONE & JOINT JOURNAL, 2015, 97B (07): : 883 - 889
  • [2] A Ten-Year Radiostereometric Analysis of Polyethylene Wear Between Oxidized Zirconium and Cobalt Chrome Articulations in Total Hip Arthroplasty
    Salipas, Andrew
    Poole, Andrew S.
    Teeter, Matthew G.
    Somerville, Lyndsay E.
    Naudie, Douglas D.
    McCalden, Richard W.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07): : S692 - S696
  • [3] A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up
    Wang, ShiJun
    Zhang, ShuDong
    Zhao, YuChi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2013, 8
  • [4] Oxidized zirconium versus cobalt- chrome femoral heads in total hip arthroplasty: a multicentre prospective randomized controlled trial with ten years' follow- up
    Kayani, B.
    Baawa-Ameyaw, J.
    Fontalis, A.
    Tahmassebi, J.
    Wardle, N.
    Middleton, R.
    Stephen, A.
    Hutchinson, J.
    Haddad, F. S.
    BONE & JOINT JOURNAL, 2022, 104B (07): : 833 - 843
  • [5] Highly Cross-Linked Polyethylene Reduces Wear and Revision Rates in Total Hip Arthroplasty A 10-Year Double-Blinded Randomized Controlled Trial
    Devane, Peter A.
    Horne, James Geoffrey
    Ashmore, Alexander
    Mutimer, Jonathon
    Kim, Woosung
    Stanley, James
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (20): : 1703 - 1714
  • [6] Minimum 10-Year Follow-Up of Cementless Total Hip Arthroplasty With a 32-mm Cobalt-Chromium Head on Highly Cross-Linked Polyethylene and a Tapered, Fiber Metal Proximally Coated Femoral Stem
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    JOURNAL OF ARTHROPLASTY, 2021, 36 (02): : 647 - 652
  • [7] The Seven-Year Wear of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty A Double-Blind, Randomized Controlled Trial Using Radiostereometric Analysis
    Thomas, Geraint E. R.
    Simpson, David J.
    Mehmood, Shahid
    Taylor, Adrian
    McLardy-Smith, Peter
    Gill, Harinderjit Singh
    Murray, David W.
    Glyn-Jones, Sion
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (08): : 716 - 722
  • [8] The Use of Large Metal Heads in Thin Vitamin E-Doped Cross-Linked Polyethylene Inserts Does Not Increase Polyethylene Wear in Total Hip Arthroplasty: 5-Year Results From a Randomized Controlled Trial
    Tsikandylakis, Georgios
    Mortensen, Kristian R. L.
    Gromov, Kirill
    Mohaddes, Maziar
    Malchau, Henrik
    Troelsen, Anders
    JOURNAL OF ARTHROPLASTY, 2024, 39 (07): : 1804 - 1810
  • [9] Comparison of 5-year cup and stem migration between ceramic-on-ceramic and ceramic-on-polyethylene bearing in press-fit total hip arthroplasty: a randomised controlled trial using radiostereometric analysis
    Klaassen, Amanda D.
    van Loon, Justin
    Willigenburg, Nienke W.
    Koster, Lennard A.
    Kaptein, Bart L.
    Van der Hulst, Victor P. M.
    Haverkamp, Daniel
    Moojen, Dirk Jan F.
    Poolman, Rudolf W.
    HIP INTERNATIONAL, 2024, 34 (06) : 701 - 716
  • [10] Vitamin E-blended highly cross-linked polyethylene liners in total hip arthroplasty: a randomized, multicenter trial using virtual CAD-based wear analysis at 5-year follow-up
    Busch, Andre
    Jaeger, Marcus
    Klebingat, Stefan
    Baghdadi, Josef
    Floerkemeier, Thilo
    Huetter, Felix
    Grupp, Thomas M.
    Haversath, Marcel
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (12) : 1859 - 1866