Interrogation of a fluoropolymer dispersion manufactured with a non-fluorinated polymerization aid for targeted and non-targeted fluorinated residuals by liquid chromatography high resolution mass spectrometry

被引:1
作者
Sworen, John C. [1 ]
Morken, Peter A. [1 ]
Smith, Adam P. [2 ]
Boyle, Jill E. [1 ]
Garcia, Maria D. Cervantes [1 ]
Kramer, Jordyn [1 ]
Wadsley, Michael P. [1 ]
Davis, Michael C. [1 ]
机构
[1] Chemours Co, 201 Discovery Blvd, Newark, DE 19713 USA
[2] Chemours Co, 8480 DuPont Rd, Washington, WV USA
关键词
Fluoropolymer; NFS (non-fluorinated surfactant) PA (polymerization aid); Non-targeted; Residuals; Polytetrafluoroethylene; PERFLUOROALKYL SUBSTANCES; POLYFLUOROALKYL; IDENTIFICATION; ACID;
D O I
10.1016/j.chroma.2024.465369
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent advances in fluoropolymer polymerization have focused on replacing perfluorinated polymerization aids (PAs) with hydrocarbon-based alternatives. Hydrocarbon PAs are vulnerable to fluorinated radicals during polymerization, leading to the creation of hundreds of process-specific polyfluorinated residuals. These residuals, which include low molecular weight extractable or leachable impurities, are challenging to detect at trace levels. This study investigates a polytetrafluoroethylene (PTFE) dispersion prepared with a hydrocarbon-based surfactant (DOSS) to measure these process-specific fluorinated residues. Liquid chromatography high resolution mass spectrometry is one of the few analytical methods that offers the sensitivity and selectivity required to detect these residuals in complex matrices at concentrations as low as parts per billion. The results indicate that using a hydrocarbon PA during emulsion polymerization produces numerous polyfluorinated residuals. These must be identified and monitored to develop effective abatement strategies, ensuring responsible fluoropolymer manufacturing.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Isotope Cluster-Based Compound Matching in Gas Chromatography/Mass Spectrometry for Non-Targeted Metabolomics
    Wegner, Andre
    Sapcariu, Sean C.
    Weindl, Daniel
    Hiller, Karsten
    ANALYTICAL CHEMISTRY, 2013, 85 (08) : 4030 - 4037
  • [22] Comparing targeted and non-targeted high-resolution mass spectrometric approaches for assessing advanced oxidation reactor performance
    Parry, Emily
    Young, Thomas M.
    WATER RESEARCH, 2016, 104 : 72 - 81
  • [23] Wood profiling by non-targeted liquid chromatography high-resolution mass spectrometry: Part 2, Detection of the geographical origin of spruce wood (Picea abies) by determination of metabolite pattern
    Creydt, Marina
    Lautner, Silke
    Fromm, Joerg
    Fischer, Markus
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1663
  • [24] A non-targeted metabolomic approach based on reversed-phase liquid chromatography-mass spectrometry to evaluate coffee roasting process
    Perez-Miguez, Raquel
    Sanchez-Lopez, Elena
    Plaza, Merichel
    Castro-Puyana, Maria
    Luisa Marina, Maria
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (30) : 7859 - 7870
  • [25] Simultaneous targeted and non-targeted analysis of per- and polyfluoroalkyl substances in environmental samples by liquid chromatography-ion mobility-quadrupole time of flight-mass spectrometry and mass defect analysis
    de Vega, Raquel Gonzalez
    Cameron, Alex
    Clases, David
    Dodgen, Tyren M.
    Doble, Philip A.
    Bishop, David P.
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1653
  • [26] Establishment of Retention Index Library on Gas Chromatography-Mass Spectrometry for Non-targeted Metabolite Profiling Approach
    Choi, Hoon
    Moon, Joon-Kwan
    Seo, Jong-Su
    Kim, Jeong-Han
    JOURNAL OF THE KOREAN SOCIETY FOR APPLIED BIOLOGICAL CHEMISTRY, 2013, 56 (01): : 87 - 90
  • [27] Practical non-targeted gas chromatography/mass spectrometry-based metabolomics platform for metabolic phenotype analysis
    Tsugawa, Hiroshi
    Bamba, Takeshi
    Shinohara, Masakazu
    Nishiumi, Shin
    Yoshida, Masaru
    Fukusaki, Eiichiro
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2011, 112 (03) : 292 - 298
  • [28] Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
    McCord, James
    Strynar, Mark
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (146):
  • [29] Use of Passive and Grab Sampling and High-Resolution Mass Spectrometry for Non-Targeted Analysis of Emerging Contaminants and Their Semi-Quantification in Water
    Tadic, Dorde
    Manasfi, Rayana
    Bertrand, Marine
    Sauvetre, Andres
    Chiron, Serge
    MOLECULES, 2022, 27 (10):
  • [30] Non-targeted, high resolution mass spectrometry strategy for simultaneous monitoring of xenobiotics and endogenous compounds in green sea turtles on the Great Barrier Reef
    Heffernan, Amy L.
    Gomez-Ramos, Maria M.
    Gaus, Caroline
    Vijayasarathy, Soumini
    Bell, Ian
    Hof, Christine
    Mueller, Jochen F.
    Gomez-Ramos, Maria J.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 599 : 1251 - 1262