State-of-the-Art Quantification of Liver Iron With MRI-Vendor Implementation and Available Tools

被引:0
作者
Tipirneni-Sajja, Aaryani [1 ,2 ]
Shrestha, Utsav [1 ,2 ]
Esparza, Juan [1 ]
Morin, Cara E. [3 ,4 ]
Kannengiesser, Stephan [5 ]
Roberts, Nathan T. [6 ]
Peeters, Johannes M. [7 ]
Sharma, Samir D. [8 ]
Hu, Houchun H. [9 ]
机构
[1] Univ Memphis, Dept Biomed Engn, Memphis, TN USA
[2] St Jude Childrens Res Hosp, Diagnost Imaging, Memphis, TN USA
[3] Cincinnati Childrens Hosp, Dept Radiol, Cincinnati, OH USA
[4] Univ Cincinnati, Coll Med, Dept Radiol, Cincinnati, OH USA
[5] Siemens Healthineers AG, MR Applicat Predev, Erlangen, Germany
[6] GE HealthCare, MR Clin Solut & Res Collaborat, Waukesha, WI USA
[7] Philips, MR Clin Sci, Eindhoven, Netherlands
[8] Canon Med Res USA Inc, Mayfield Village, OH USA
[9] Univ Colorado, Radiol, Anschutz Med Campus, Aurora, CO USA
基金
美国国家卫生研究院;
关键词
LIC; iron overload; R2*; R2; vendor; software; MAGNETIC-RESONANCE; FAT QUANTIFICATION; HEPATIC STEATOSIS; CHELATING THERAPY; OVERLOAD; THALASSEMIA; CHILDREN; BIOPSY; R2-ASTERISK; DISEASE;
D O I
10.1002/jmri.29526
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The role of MRI to estimate liver iron concentration (LIC) for identifying patients with iron overload and guiding the titration of chelation therapy is increasingly established for routine clinical practice. However, the existence of multiple MRI-based LIC quantification techniques limits standardization and widespread clinical adoption. In this article, we review the existing and widely accepted MRI-based LIC estimation methods at 1.5 T and 3 T: signal intensity ratio (SIR) and relaxometry (R2 and R2*) and discuss the basic principles, acquisition and analysis protocols, and MRI-LIC calibrations for each technique. Further, we provide an up-to-date information on MRI vendor implementations and available offline commercial and free software for each MRI-based LIC quantification approach. We also briefly review the emerging and advanced MRI techniques for LIC estimation and their current limitations for clinical use. Lastly, we discuss the implications of MRI-based LIC measurements on clinical use and decision-making in the management of patients with iron overload. Some of the key highlights from this review are as follows: 1) Both R2 and R2* can estimate accurate and reproducible LIC, when validated acquisition parameters and analysis protocols are applied, 2) Although the Ferriscan R2 method has been widely used, recent consensus and guidelines endorse R2*-MRI as the most accurate and reproducible method for LIC estimation, 3) Ongoing efforts aim to establish R2*-MRI as the standard approach for quantifying LIC, and 4) Emerging R2*-MRI techniques employ radial sampling strategies and offer improved motion compensation and broader dynamic range for LIC estimation.
引用
收藏
页码:1110 / 1132
页数:23
相关论文
共 118 条
[1]   R2 relaxometry with MRI for the quantification of tissue iron overload in β-thalassemic patients [J].
Alexopoulou, E ;
Stripeli, F ;
Baras, P ;
Seimenis, L ;
Kattamis, A ;
Ladis, V ;
Efstathopoulos, E ;
Brountzos, EN ;
Kelekis, AD ;
Kelekis, NL .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (02) :163-170
[2]   MR quantification of hepatic iron concentration [J].
Alústiza, JM ;
Artetxe, J ;
Castiella, A ;
Agirre, C ;
Emparanza, JI ;
Otazua, P ;
García-Bengoechea, M ;
Barrio, J ;
Mújica, F ;
Recondo, JA .
RADIOLOGY, 2004, 230 (02) :479-484
[3]   Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload [J].
Anderson, LJ ;
Holden, S ;
Davis, B ;
Prescott, E ;
Charrier, CC ;
Bunce, NH ;
Firmin, DN ;
Wonke, B ;
Porter, J ;
Walker, JM ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2001, 22 (23) :2171-2179
[4]   Hepatic iron concentration and total body iron stores in thalassemia major. [J].
Angelucci, E ;
Brittenham, GM ;
McLaren, CE ;
Ripalti, M ;
Baronciani, D ;
Giardini, C ;
Galimberti, M ;
Polchi, P ;
Lucarelli, G .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (05) :327-331
[5]  
ANGELUCCI E, 1995, BRIT J HAEMATOL, V89, P757
[6]   Free-breathing quantification of hepatic fat in healthy children and children with nonalcoholic fatty liver disease using a multi-echo 3-D stack-of-radial MRI technique [J].
Armstrong, Tess ;
Ly, Karrie V. ;
Murthy, Smruthi ;
Ghahremani, Shahnaz ;
Kim, Grace Hyun J. ;
Calkins, Kara L. ;
Wu, Holden H. .
PEDIATRIC RADIOLOGY, 2018, 48 (07) :941-953
[7]  
Bacher M., 2014, INT SOC MAGN RESON I
[8]   Quantitative magnetic resonance imaging of hepatic steatosis: Validation in ex vivo human livers [J].
Bannas, Peter ;
Kramer, Harald ;
Hernando, Diego ;
Agni, Rashmi ;
Cunningham, Ashley M. ;
Mandal, Rakesh ;
Motosugi, Utaroh ;
Sharma, Samir D. ;
del Rio, Alejandro Munoz ;
Fernandez, Luis ;
Reeder, Scott B. .
HEPATOLOGY, 2015, 62 (05) :1444-1455
[9]  
Bardo DM., 2021, MRI T2 LIVER IRON CO
[10]   Biexponential R2*relaxometry for estimation of liver iron concentration in children: A better fit for high liver iron states [J].
Barrera, Christian A. ;
Khrichenko, Dmitry ;
Serai, Suraj D. ;
Hartung, Helge D. ;
Biko, David M. ;
Otero, Hansel J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (04) :1191-1198