Experimental Investigation of the Behavior of Loaded Fiber Reinforced Concrete Beam Exposed to Fire

被引:0
作者
Beheshti, Seyed Saeed [1 ]
Safi, Mohammad [2 ]
Rahmani, Khosro [1 ]
机构
[1] Shahid Beheshti Univ, Fac Mech & Energy Engn, Tehran 1983969411, Iran
[2] Shahid Beheshti Univ, Fac Civil Water & Environm Engn, Tehran 1983969411, Iran
关键词
Direct fire; Fiber reinforced concrete; Flexural test; Durability; Spalling; MECHANICAL-PROPERTIES; MIX PROPORTION; STRENGTH; POLYPROPYLENE; RESISTANCE;
D O I
10.1007/s12205-024-0335-x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effect of direct fire on flexural behavior of small-scale fiber reinforced concrete beams under sustained loading has been studies through an experimental investigation. A mix of synthetic polypropylene structural macro and micro fibers has been used to obtain the effect of mixed fiber dosage on bearing capacity of simply supported beam under direct flame at its bottom face. The load-deflection, temperature gradient, spalling and durability time until collapse has been recorded and compared in different conditions. In order to know the effect of load level, the tests have been performed for 40% and 70% of the ultimate member capacity at normal temperature. Based on obtained test results, the use of macro synthetic fibers can increase the flexural ductility more than 50% and the durability time until failure up to 27%. The post fire behavior curves of all samples at the cooling phase have also been checked until the beam failure has been occurred including the weight losses due to spalling for both heating and cooling phases. A comparison with the results of conventional post fire loading tests on cooled samples showed that the results can be underestimated about 1.5 times compared to the direct fire test. It has also been shown that the level of sustained load directly affects the capacity, durability and ductility while the increase in the number of fibers do not necessarily improve the behavior in the same manner.
引用
收藏
页码:5151 / 5161
页数:11
相关论文
共 29 条
  • [1] Effects of high temperatures on mechanical behavior of high strength concrete reinforced with high performance synthetic macro polypropylene (HPP) fibres
    Abaeian, Reza
    Behbahani, Hamid Pesaran
    Moslem, Shahram Jalali
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2018, 165 : 631 - 638
  • [2] Behavior and flexural strength of fire-damaged high-strength reinforced rectangular concrete beams with tension or compression zones exposed to fire repaired with CFRP sheets
    Abdulrahman, Alan Saeed
    Kadir, Mohamed Raouf Abdul
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2021, 15
  • [3] Mechanical properties of steel fiber-reinforced UHPC mixtures exposed to elevated temperature: Effects of exposure duration and fiber content
    Ahmad, Shamsad
    Rasul, Mehboob
    Adekunle, Saheed Kolawole
    Al-Dulaijan, Salah U.
    Maslehuddin, Mohammed
    Ali, Syed Imran
    [J]. COMPOSITES PART B-ENGINEERING, 2019, 168 : 291 - 301
  • [4] [Anonymous], 1999, ISO 834 1 FIRE RESIS
  • [5] [Anonymous], 2006, Standard Test Method for Pullout Strength of Hardened Concrete, P1, DOI [DOI 10.1520/D2166-06, DOI 10.1520/E0965-96R06.2]
  • [6] ASTM C1018-97, 1998, STRUCTURAL TEST METH, P514
  • [7] Experimental behavior of ultra high performance fiber reinforced concrete beams under fire conditions
    Banerji, Srishti
    Kodur, Venkatesh
    Solhmirzaei, Roya
    [J]. ENGINEERING STRUCTURES, 2020, 208
  • [8] Analysis of thermal-induced spalling tests on high to ultra-high performance concrete subjected to standard fire
    Bensalem, Hadjira
    Djaknoun, Samira
    Ouedraogo, Evariste
    Amrouche, Ramdane
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2021, 15
  • [9] Bodnarova Lenka, 2015, ScientificWorldJournal, V2015, P371913, DOI 10.1155/2015/371913
  • [10] Mechanical Properties of Concrete with Steel and Polypropylene Fibres at Elevated Temperatures
    Bosnjak, Josipa
    Sharma, Akanshu
    Grauf, Kevin
    [J]. FIBERS, 2019, 7 (02):