A computationally efficient approach of tuned mass damper design for a nuclear cabinet based on two-step machine learning and optimization methods

被引:0
作者
Go, Chaeyeon [1 ]
Kwag, Shinyoung [1 ]
Eem, Seunghyun [2 ]
Kwak, Jinsung [3 ]
Oh, Jinho [3 ]
机构
[1] Hanbat Natl Univ, Dept Civil & Environm Engn, Daejeon 34158, South Korea
[2] Kyungpook Natl Univ, Dept Convergence & Fus Syst Engn, Major Plant Syst Engn, Sangju, South Korea
[3] Korea Atom Energy Res Inst, 111 Daedeok Daero, Daejeon, 34057, South Korea
基金
新加坡国家研究基金会;
关键词
Nuclear power plant; Electrical cabinet; Tuned mass damper; Shake table test; Seismic response; Two-Step machine learning; Optimization; Time history analysis; CENTRAL COMPOSITE DESIGN; PARAMETERS; ABSORBER; STATE;
D O I
10.1016/j.advengsoft.2024.103736
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Enhancing nuclear power plant (NPP) safety is demanded because of the recent beyond-design-basis earthquake near a NPP. Therefore, research on improving the seismic performance of the electrical cabinet, which ensures the safe operation of NPPs, is needed. In this paper, a tuned mass damper (TMD) is employed to control the seismic response of cabinet. To design the TMD, we employ existing design equations or perform numerical model-based optimization. However, limitations, such as inconsistencies with targeted control of the load and structure, the possibility of converging a local solution, and the high cost of numerical analysis. Therefore, this paper proposes a two-step machine learning and optimization method. Such an approach is utilized to find the optimal global design solution and reduce numerical analysis costs. Each step involves the design of experiment (DOE), response surface, and optimization. Notably, range setting in the DOE accounts for the difference between each step. In the first step, the sampling range is widened to determine the relationship between the design variables and the cabinet's response, and in the second step, the sampling range is narrowed depending on the result of the first step. Consequently, the proposed method reduced the cabinet's response by 35.4 % on average and numerical analysis cost declined by 1/3.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] [Anonymous], 1997, Passive energy dissipation systems in structural engineering
  • [2] Optimum parameters of tuned mass damper for damped main system
    Bakre, S. V.
    Jangid, R. S.
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2007, 14 (03) : 448 - 470
  • [3] Tuning the parameters of an artificial neural network using central composite design and genetic algorithm
    Bashiri, M.
    Geranmayeh, A. Farshbaf
    [J]. SCIENTIA IRANICA, 2011, 18 (06) : 1600 - 1608
  • [4] Boroschek R.a.R., 2001, DAMAGE OBSERVED SALV
  • [5] Simplified Approach for Seismic Risk Assessment of Cabinet Facility in Nuclear Power Plants Based on Cumulative Absolute Velocity
    Cao, Anh-Tuan
    Thanh-Tuan Tran
    Thi-Hong-Xuyen Nguyen
    Kim, Dookie
    [J]. NUCLEAR TECHNOLOGY, 2020, 206 (05) : 743 - 757
  • [6] Application of Tuned Mass Damper to Mitigation of the Seismic Responses of Electrical Equipment in Nuclear Power Plants
    Cho, Sung Gook
    Chang, Seongkyu
    Sung, Deokyong
    [J]. ENERGIES, 2020, 13 (02)
  • [7] Chock G., 2006, COMPILATION OBSERVAT, P31
  • [8] Chopra A.K., 2007, Dynamics of Structures: Theory and Applications to Earthquake Engineering, V3rd
  • [9] Efficient space-filling and non-collapsing sequential design strategies for simulation-based modeling
    Crombecq, K.
    Laermans, E.
    Dhaene, T.
    [J]. EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2011, 214 (03) : 683 - 696
  • [10] Den Hartog JP, 1956, Mechanical vibrations, V87