Standardized diagnostic reference levels for paediatric interventional cardiology: Data from an Italian referral centre

被引:0
作者
Giannone, Angelo [1 ]
De Monte, Francesca [1 ]
Colangelo, Manuela [2 ]
Di Salvo, Giovanni [3 ]
Fraccaro, Chiara [4 ]
Sirico, Domenico [3 ]
Paiusco, Marta [1 ]
Castaldi, Biagio [3 ]
机构
[1] IRCCS, Veneto Inst Oncol IOV, Med Phys Dept, Via Gattamelata 64, I-35128 Padua, Italy
[2] Univ Padua, Padua, Italy
[3] Univ Padua, Dept Woman & Childs Hlth, Paediat Cardiol Unit, Padua, Italy
[4] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Intervent Cardiol Unit, Padua, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2024年 / 124卷
关键词
Pediatrics; Interventional Cardiology; Diagnostic reference levels; Report RP185; Dose Optimization; CARDIAC-CATHETERIZATION; HEART-DISEASE; CHILDREN; RISKS;
D O I
10.1016/j.ejmp.2024.104487
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To provide data on radiation exposure in paediatric interventional cardiology procedures, addressing the scarcity of valuable Local Diagnostic Reference Levels (LDRLs),established according to the standardized approach proposed by the Radiation Protection 185 report (RP185). Methods: Paediatric catheterization procedures conducted at the University-Hospital of Padua from September 2019 to December 2022 were stratified by body weight (BW) classes and procedure type. LDRLs were calculated for groups with at least 20 patients as the 75th percentile of Kerma-Area Product (PKA) and Air Kerma at reference point (Ka,r) values. Kruskal-Wallis test was applied to evaluate differences in the dose-related quantities among BW groups for a selected procedure and among procedures for the same BW class. Results were compared with recent literature. Results: A total of 838 procedures were analysed. LDRL were provided for five therapeutic procedures. The 75th percentile of PKA and Ka,r increases with weight, regardless procedure type. PKA and Ka,r are generally statistically different between BW groups, for both diagnostic and therapeutic procedures, and between different procedures at fixed weight group. Angioplasty and Right Ventricular Outflow Tract treatments (PVR) showed exposure values approximately doubled then other procedures. PKA/(BW & sdot;FT) is not statistically different among procedures except for Atrial Septal Defect (ASD) closures. LDRL values from this study are generally lower than the published ones. Conclusions: The study stands out as one of the few that presents a considerable number of LDRLs for weight categories and procedure types with a sample size of at least 20 patients per group, in agreement with RP185. PKA shows strong correlation with the product BW & sdot;FT.
引用
收藏
页数:7
相关论文
共 29 条
  • [1] Cardiac catheterization and long-term chromosomal damage in children with congenital heart disease
    Andreassi, Maria Grazia
    Ait-Ali, Lamia
    Botto, Nicoletta
    Manfredi, Samantha
    Mottola, Gaetano
    Picano, Eugenio
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 (22) : 2703 - 2708
  • [2] Diagnostic Reference Levels in Interventional Pediatric Cardiology: Two-Year Experience in a Tertiary Referral Hospital in Latin America
    Aristizabal, Ana M.
    Gutierrez, Jaiber A.
    Ramirez, Emmanuel
    Mejia-Quinones, Valentina
    Ubeda, Carlos
    Mosquera, Walter Fernando
    Mosquera, Walter
    [J]. CHILDREN-BASEL, 2023, 10 (10):
  • [3] Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization
    Bacher, K
    Bogaert, E
    Lapere, R
    De Wolf, D
    Thierens, H
    [J]. CIRCULATION, 2005, 111 (01) : 83 - 89
  • [4] Local DRLs and automated risk estimation in paediatric interventional cardiology
    Buytaert, Dimitri
    Vandekerckhove, Kristof
    Panzer, Joseph
    Rubbens, Lukas
    De Wolf, Daniel
    Bacher, Klaus
    [J]. PLOS ONE, 2019, 14 (07):
  • [5] Radiation Dose to the Pediatric Cardiac Catheterization and Intervention Patient
    Chida, Koichi
    Ohno, Tadayuki
    Kakizaki, Shuhei
    Takegawa, Mika
    Yuuki, Hiroko
    Nakada, Mitsuru
    Takahashi, Shoki
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1175 - 1179
  • [6] Typical values for pediatric interventional cardiology catheterizations: A standardized approach towards Diagnostic Reference Level establishment
    De Monte, Francesca
    Castaldi, Biagio
    Branchini, Marco
    Bettinelli, Andrea
    Milanesi, Ornella
    Paiusco, Marta
    Roggio, Antonella
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 134 - 141
  • [7] eurosafeimaging, 2018, Radiation Protection N 185. European guidelines on diagnostic Reference Levels fo Pediatric Imaging
  • [8] Giannone Angelo, 2024, Zenodo, DOI 10.5281/ZENODO.10468156
  • [9] Patient radiation doses in paediatric interventional cardiology procedures: a review
    Harbron, R. W.
    Dreuil, S.
    Bernier, M-O
    Pearce, M. S.
    Thierry-Chef, I.
    Chapple, C-L
    Baysson, H.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : R131 - R144
  • [10] Survival adjusted cancer risks attributable to radiation exposure from cardiac catheterisations in children
    Harbron, Richard W.
    Chapple, Claire-Louise
    O'Sullivan, John J.
    Best, Kate E.
    de Gonzalez, Amy Berrington
    Pearce, Mark S.
    [J]. HEART, 2017, 103 (05) : 341 - 346