CT guided versus non-image guided bone marrow aspiration and biopsy: Comparison of indications, specimen quality and cost

被引:0
|
作者
Alshumrani, Yousef [1 ]
Droukas, Daniel [2 ]
Carney, Brian J. [3 ]
Willim, Robert [4 ]
Brook, Alexander [2 ]
Wu, Jim S. [2 ]
机构
[1] King Khalid Univ, Dept Internal Med, Div Radiol, 7887 Alfara St, Abha 62529, Saudi Arabia
[2] Beth Israel Deaconess Med Ctr, Dept Radiol, 330 Brookline Ave, Boston, MA 02215 USA
[3] Beth Israel Deaconess Med Ctr, Dept Med, Div Hematol & Hematol Malignancies, 330 Brookline Ave, Boston, MA 02215 USA
[4] Beth Israel Deaconess Med Ctr, Dept Pathol, 330 Brookline Ave, Boston, MA 02215 USA
关键词
Bone marrow biopsy; Bone marrow aspirate; CT guidance; TRENDS; PAIN; MORBIDITY; DEVICE; SAFETY;
D O I
10.1016/j.clinimag.2024.110236
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the indications, specimen quality, and cost of CT versus non-image guided bone marrow aspirate and biopsy (BMAB). Methods: All CT and non-image guided BMAB performed from January 2013-July 2022 were studied. Body-massindex (BMI), skin-to-bone distance, aspirate, and core specimen quality, and core sample length were documented. Indications for CT guided BMAB were recorded. Categorical variables were compared using chi-squared test and continuous variables using Mann-Whitney test. Analysis of per-biopsy factors used linear mixed-effect models to adjust for clustering. Cost of CT and non-image guided BMAB was taken from patient billing data. Results: There were 301 CT and 6535 non-image guided BMABs studied. All CT guided BMAB were studied. A subset of 317 non-image guided BMAB was selected randomly from the top ten CT BMAB referrers. BMI (kg/m2) and skin-to-bone distance (cm) was higher in the CT versus the non-image guided group; 34.4 v 26.8, p < 0.0001; 4.8 v 2.5, p < 0.0001, respectively. Aspirate and core sample quality were not different between groups, p = 0.21 and p = 0.12, respectively. CT guided core marrow samples were longer, p < 0.0001. The most common CT BMAB referral indications were large body habitus (47.7 %), failed attempt (18.8 %) and not stated (17.4 %). Cost of a CT guided BMAB with conscious sedation was $3945 USD versus $310 USD for non-image guided. Conclusion: CT guided BMAB are commonly performed in patients with large body habitus and failed attempt. However, the cost is 12.7 fold higher with no increase in specimen quality. These findings can help referrers be cost conscious.
引用
收藏
页数:5
相关论文
共 14 条
  • [1] Image Guided Bone Marrow Biopsy
    Kaufman, Claire S.
    Kuo, Keith T.
    Anand, Keshav
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 24 (03)
  • [2] Safety of CT-Guided Bone Marrow Biopsy in Thrombocytopenic Patients: A Retrospective Review
    Liu, Bo
    Limback, Joseph
    Kendall, Melissa
    Valente, Michael
    Armaly, Jamil
    Grekoski, Vincent
    Pinizzotto, Alex
    Burt, Jeremy
    Ward, Thomas J.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (12) : 1727 - 1731
  • [3] CT-guided bone marrow aspirations and biopsies: retrospective study and comparison with blind procedures
    Chang, C. Y.
    Husseini, J. S.
    Moreira, A.
    Simeone, F. J.
    Yee, A. J.
    Bredella, M. A.
    Hasserjian, R.
    SKELETAL RADIOLOGY, 2020, 49 (08) : 1285 - 1294
  • [4] CT-guided transthoracic needle biopsy of pulmonary lesions: comparison between the cutting needle and aspiration needle
    Huang, Zhen-Guo
    Sun, Hong-Liang
    Wang, Cun-Li
    Gao, Bao-Xiang
    Chen, He
    Yang, Min-Xing
    Chen, Xiao-Liang
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1118)
  • [5] Percutaneous CT-guided core needle biopsy versus fine needle aspiration in diagnosing pneumonia and mimics of pneumonia
    Thanos, L
    Galani, P
    Mylona, S
    Pomoni, M
    Mpatakis, N
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 27 (04) : 329 - 334
  • [6] Complications and specimen quality in transrectal ultrasound guided prostate biopsy: Comparison of 16G and 18G needles
    Bayraktar, Ahmet Murat
    Olcucuoglu, Erkan
    Hasirci, Eray
    Nalbant, Ismail
    Yesil, Suleyman
    KUWAIT MEDICAL JOURNAL, 2020, 52 (02): : 134 - 137
  • [7] A Comparison of Ultrasound-Guided Fine Needle Aspiration versus Core Needle Biopsy for Thyroid Nodules: Pain, Tolerability, and Complications
    Jeong, Eun Ji
    Chung, Sae Rom
    Baek, Jung Hwan
    Choi, Young Jun
    Kim, Jae Kyun
    Lee, Jeong Hyun
    ENDOCRINOLOGY AND METABOLISM, 2018, 33 (01) : 114 - 120
  • [8] Pain and anxiety during bone marrow aspiration/biopsy: Comparison of ratings among patients versus health-care professionals
    Liden, Y.
    Olofsson, N.
    Landgren, O.
    Johansson, E.
    EUROPEAN JOURNAL OF ONCOLOGY NURSING, 2012, 16 (03) : 323 - 329
  • [9] Is it sufficient to evaluate bone marrow involvement in newly diagnosed lymphomas using 18F-FDG PET/CT and/or routine iliac crest biopsy? A new approach of PET/CT-guided targeted bone marrow biopsy
    Bing Hao
    Long Zhao
    Na-na Luo
    Dan Ruan
    Yi-zhen Pang
    Wei Guo
    Hao Fu
    Xiu-yu Guo
    Zuo-ming Luo
    Jing Wu
    Hao-jun Chen
    Hua Wu
    Long Sun
    BMC Cancer, 18
  • [10] Is it sufficient to evaluate bone marrow involvement in newly diagnosed lymphomas using 18F-FDG PET/CT and/or routine iliac crest biopsy? A new approach of PET/CT-guided targeted bone marrow biopsy
    Hao, Bing
    Zhao, Long
    Luo, Na-na
    Ruan, Dan
    Pang, Yi-zhen
    Guo, Wei
    Fu, Hao
    Guo, Xiu-yu
    Luo, Zuo-ming
    Wu, Jing
    Chen, Hao-jun
    Wu, Hua
    Sun, Long
    BMC CANCER, 2018, 18