Assessment of Effectiveness of the Algorithm for Automated Quantitative Analysis of Metallic Strut Tissue Short-Term Coverage with Intravascular Optical Coherence Tomography

被引:0
作者
Fluder-Wlodarczyk, Joanna [1 ]
Schneider, Zofia [2 ]
Pawlowski, Tomasz [1 ]
Wojakowski, Wojciech [1 ]
Gasior, Pawel [1 ]
Pociask, Elzbieta [3 ]
机构
[1] Med Univ Silesia, Div Cardiol & Struct Heart Dis, PL-40635 Katowice, Poland
[2] AGH Univ Krakow, Fac Geol Geophys & Environm Protect, PL-30059 Krakow, Poland
[3] AGH Univ Krakow, Dept Biocybernet & Biomed Engn, PL-30059 Krakow, Poland
关键词
coronary artery disease; optical coherence tomography; OCT; intravascular imaging; PCI; DUAL ANTIPLATELET THERAPY; ELUTING STENT THROMBOSIS; BLEEDING RISK PATIENTS; NEOINTIMAL COVERAGE; HEALING RESPONSE; ULTRASOUND; REPRODUCIBILITY; IMPLANTATION; PREDICTORS; DURATION;
D O I
10.3390/jcm13154336
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Due to its high resolution, optical coherence tomography (OCT) is the most suitable modality for neointimal coverage assessments. Evaluation of stent healing seems crucial to accurately define their safety profile since delayed healing is connected with stent thrombosis. This study aimed to present an algorithm for automated quantitative analysis of stent strut coverage at the early stages of vessel healing in intravascular OCT. Methods: A set of 592 OCT frames from 24 patients one month following drug-eluting stent implantation was used to assess the algorithm's effectiveness. Struts not covered on any side or covered but only on one side were categorized as uncovered. The algorithm consists of several key steps: preprocessing, vessel lumen segmentation, automatic strut detection, and measurement of neointimal thickness. Results: The proposed algorithm proved its efficiency in lumen and stent area estimation versus manual reference. It showed a high positive predictive value (PPV) (89.7%) and true positive rate (TPR) (91.4%) in detecting struts. A qualitative assessment for covered and uncovered struts was characterized by high TPR (99.1% and 80%, respectively, for uncovered and covered struts) and PPV (77.3% and 87%). Conclusions: The proposed algorithm demonstrated good agreement with manual measurements. Automating the stent coverage assessment might facilitate imaging analysis, which might be beneficial in experimental and clinical settings.
引用
收藏
页数:11
相关论文
共 39 条
[1]   Incidence and predictors of drug-eluting stent thrombosis during and after discontinuation of thienopyridine treatment [J].
Airoldi, Flavio ;
Colombo, Antonio ;
Morici, Nuccia ;
Latib, Azeem ;
Cosgrave, John ;
Buellesfeld, Lutz ;
Bonizzoni, Erminio ;
Carlino, Mauro ;
Gerckens, Ulrich ;
Godino, Cosmo ;
Melzi, Gloria ;
Michev, Iassen ;
Montorfano, Matteo ;
Sangiorgi, Giuseppe Massimo ;
Qasim, Asif ;
Chieffo, Alaide ;
Briguori, Carlo ;
Grube, Eberhard .
CIRCULATION, 2007, 116 (07) :745-754
[2]   Intra- and interobserver reliability and intra-catheter reproducibility using frequency domain optical coherence tomography for the evaluation of morphometric stent parameters and qualitative assessment of stent strut coverage [J].
Antonsen, Lisbeth ;
Thayssen, Per ;
Junker, Anders ;
Veien, Karsten Tange ;
Hansen, Henrik Steen ;
Hansen, Knud Norregaard ;
Hougaard, Mikkel ;
Jensen, Lisette Okkels .
CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2015, 16 (08) :469-477
[3]   Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage [J].
Barlis, Peter ;
Dimopoulos, Konstantinos ;
Tanigawa, Jun ;
Dzielicka, Ewa ;
Ferrante, Giuseppe ;
Del Furia, Francesca ;
Di Mario, Carlo .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 141 (02) :151-156
[4]   Intracoronary Optical Coherence Tomography: A Comprehensive Review Clinical and Research Applications [J].
Bezerra, Hiram G. ;
Costa, Marco A. ;
Guagliumi, Giulio ;
Rollins, Andrew M. ;
Simon, Daniel I. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (11) :1035-1046
[5]   Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography [J].
Brugaletta, Salvatore ;
Garcia-Garcia, Hector M. ;
Gomez-Lara, Josep ;
Radu, Maria D. ;
Pawar, Ravindra ;
Khachabi, Jamal ;
Bruining, Nico ;
Sabate, Manel ;
Serruys, Patrick W. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (01) :5-11
[6]   Fractional Flow Reserve or Optical Coherence Tomography to Guide Management of Angiographically Intermediate Coronary Stenosis A Single-Center Trial [J].
Burzotta, Francesco ;
Leone, Antonio Maria ;
Aurigemma, Cristina ;
Zambrano, Aniello ;
Zimbardo, Giuseppe ;
Arioti, Manfredi ;
Vergallo, Rocco ;
De Maria, Giovanni Luigi ;
Cerracchio, Emma ;
Romagnoli, Enrico ;
Trani, Carlo ;
Crea, Filippo .
JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (01) :49-58
[7]  
Byrne RA, 2024, EUR HEART J-ACUTE CA, V13, P55, DOI 10.1093/ehjacc/zuad107
[8]   Comparison of optical coherence tomography and intravascular ultrasound for the assessment of in-stent tissue coverage after stent implantation [J].
Capodanno, Davide ;
Prati, Francesco ;
Pawlowsky, Tomasz ;
Cera, Maria ;
La Manna, Alessio ;
Albertucci, Mario ;
Tamburino, Corrado .
EUROINTERVENTION, 2009, 5 (05) :538-543
[9]   Dual Antiplatelet Therapy Duration Based on Ischemic and Bleeding Risks After Coronary Stenting [J].
Costa, Francesco ;
Van Klaveren, David ;
Feres, Fausto ;
James, Stefan ;
Raber, Lorenz ;
Pilgrim, Thomas ;
Hong, Myeong-Ki ;
Kim, Hyo-Soo ;
Colombo, Antonio ;
Steg, Philippe Gabriel ;
Bhatt, Deepak L. ;
Stone, Gregg W. ;
Windecker, Stephan ;
Steyerberg, Ewout W. ;
Valgimigli, Marco .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (07) :741-754
[10]   Short-term stent strut coverage: optical coherence tomography versus high-definition intravascular ultrasound [J].
Dobrolinska, Magdalena ;
Gasior, Pawel ;
Roleder, Tomasz ;
Ochala, Andrzej ;
Wojakowski, Wojciech .
KARDIOLOGIA POLSKA, 2021, 79 (7-8) :861-863