Peripheral venous dilation using flow-mediated dilation response: A randomized crossover study

被引:0
|
作者
Endo, Hiroya [1 ]
Sekiguchi, Ryo [2 ]
Kinoshita, Michiko [1 ]
Tanaka, Katsuya [1 ,2 ]
机构
[1] Tokushima Univ Hosp, Dept Anesthesiol, 2-50-1 Kuramoto Cho, Tokushima, Tokushima 7708503, Japan
[2] Tokushima Univ, Grad Sch, Inst Biomed Sci, Dept Anesthesiol, Tokushima, Japan
关键词
Catheterization; peripheral; flow-mediated dilation; vascular access devices; vasodilation; veins; BRACHIAL-ARTERY; INTRAVENOUS CANNULATION; ENDOTHELIAL-CELLS; SHEAR-STRESS; DILATATION; VENODILATION; STRATEGIES; GUIDELINES; ACCESS;
D O I
10.1177/11297298241273642
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Venodilation is crucial in enhancing the success rate of peripheral intravenous cannulation. Flow-mediated dilation (FMD) is a vasodilatory response initiated by temporary ischemia followed by reperfusion. This crossover study aimed to test the hypothesis that FMD induces dilation of the peripheral veins of the forearm.Methods: Fifteen healthy volunteers underwent the FMD and control conditions in a randomized order. FMD involved a 5-min occlusion of blood flow in the brachial artery, followed by reperfusion, achieved by inflating and deflating a cuff placed on the upper arm. The control condition involved participants remaining at rest. The primary outcome measure was a change in the cross-sectional area of the cephalic vein post-intervention. The secondary outcomes included changes in venous diameter and perfusion index (PI).Results: FMD significantly increased the cross-sectional area of the cephalic vein compared with the control condition (relative change to baseline: 37.7% (31.4) vs 2.2% (11.7)), with a mean difference of 35.4% (95% confidence interval (CI): 16.4-54.5, p = 0.001). Both longitudinal and transverse diameters were significantly expanded with FMD compared to the control (relative change to baseline: 15.7% (15.4) vs 2.6% (3.6), p = 0.004; 18.9% (15.6) vs -0.0 (10.2), p = 0.003, respectively). Additionally, PI significantly increased with FMD compared with the control (relative change to baseline: 77.8% (56.9) vs 14.6% (36.0)), with a mean difference of 63.2% (95% CI: 31.2-95.2, p = 0.001).Conclusion: FMD application induced dilation of the cephalic vein of the forearm. The findings suggest that FMD is an effective technique for dilating the venous area and potentially improving the success rate of peripheral intravenous cannulation.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Physical Activity in Pregnancy Is Associated with Increased Flow-mediated Dilation
    Reyes, Laura M.
    Farooq, Sauleha M.
    Skow, Rachel J.
    Busch, Stephen A.
    Pyke, Kyra E.
    Khurana, Rshmi
    Chari, Radha S.
    Stickland, Michael K.
    Devolin, Maureen
    Davidge, Sandra T.
    Sobierajski, Frances
    Lugg, Anna
    Steinback, Craig D.
    Davenport, Margie H.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2020, 52 (04) : 801 - 809
  • [22] Why Isn't Flow-Mediated Dilation Enhanced in Athletes?
    Green, Daniel J.
    Rowley, Nicola
    Spence, Angela
    Carter, Howard
    Whyte, Greg
    George, Keith
    Naylor, Louise H.
    Cable, N. Timothy
    Dawson, Ellen A.
    Thijssen, Dick H. J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (01) : 75 - 82
  • [23] Does Circumferential Stress Help to Explain Flow-Mediated Dilation?
    Stoner, Lee
    Faulkner, James
    Fryer, Simon
    Lambrick, Danielle M.
    ULTRASOUND QUARTERLY, 2013, 29 (02) : 103 - 110
  • [24] Ultrasound Assessment of Flow-Mediated Dilation
    Harris, Ryan A.
    Nishiyama, Steven K.
    Wray, D. Walter
    Richardson, Russell S.
    HYPERTENSION, 2010, 55 (05) : 1075 - 1085
  • [25] Flow-Mediated Dilation Normalization Predicts Outcome in Chronic Heart Failure Patients
    Genta, Franco Tarro
    Eleuteri, Ermanno
    Temporelli, Pier Luigi
    Comazzi, Fabio
    Tidu, Massimo
    Bouslenko, Zoia
    Bertolin, Francesca
    Vigorito, Carlo
    Giannuzzi, Pantaleo
    Giallauria, Francesco
    JOURNAL OF CARDIAC FAILURE, 2013, 19 (04) : 260 - 267
  • [26] Brachial artery flow-mediated dilation is not affected by pregnancy or regular exercise participation
    Weissgerber, Tracey L.
    Davies, Gregory A. L.
    Tschakovsky, Michael E.
    CLINICAL SCIENCE, 2011, 121 (7-8) : 355 - 365
  • [27] Ultrasound Assessment of Endothelial Function: A Technical Guideline of the Flow-mediated Dilation Test
    Rodriguez-Miguelez, Paula
    Seigler, Nichole
    Harris, Ryan A.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (110):
  • [28] The association of arterial shear and flow-mediated dilation in diabetes
    Gibbs, Bethany Barone
    Dobrosielski, Devon A.
    Lima, Michael
    Bonekamp, Susanne
    Stewart, Kerry J.
    Clark, Jeanne M.
    VASCULAR MEDICINE, 2011, 16 (04) : 267 - 274
  • [29] Flow-Mediated Dilation of the Radial Artery Is Offset by Flow-Induced Reduction in Transmural Pressure
    Jiang, Benyu
    Seddon, Mike
    Fok, Henry
    Donald, Ann
    Chowienczyk, Phil
    HYPERTENSION, 2011, 57 (06) : 1145 - 1150
  • [30] Children With Type 1 Diabetes Have Delayed Flow-Mediated Dilation
    Pillay, Sarveshinee
    Anderson, Jemma
    Couper, Jennifer
    Maftei, Oana
    Gent, Roger
    Pena, Alexia Sophie
    CANADIAN JOURNAL OF DIABETES, 2018, 42 (03) : 276 - 280