Smartphone-based scans of palate models of newborns with cleft lip and palate: Outlooks for three-dimensional image capturing and machine learning plate tool

被引:2
作者
Santos, Jose Wittor de Macedo [1 ,2 ,3 ,4 ,5 ]
Mueller, Andreas Albert [2 ,3 ,4 ,5 ]
Benitez, Benito K. [2 ,3 ,4 ,5 ]
Lill, Yoriko [4 ,5 ]
Nalabothu, Prasad [2 ,3 ,4 ,5 ,6 ]
Muniz, Francisco Wilker Mustafa Gomes [7 ]
机构
[1] Univ Fed Pelotas, Sch Dent, Dept Oral & Maxillofacial Surg & Maxillofacial Pro, Pelotas, RS, Brazil
[2] Univ Hosp Basel, Dept Oral & Craniomaxillofacial Surg, Basel, Switzerland
[3] Univ Childrens Hosp Basel, Basel, Switzerland
[4] Univ Basel, Dept Biomed Engn, Facial & Cranial Anomalies Res Grp, Basel, Switzerland
[5] Univ Basel, Dept Clin Res, Basel, Switzerland
[6] Univ Ctr Dent Med UZB, Dept Paediat Oral Hlth & Orthodont, Basel, Switzerland
[7] Univ Fed Pelotas, Sch Dent, Dept Periodontol, Pelotas, RS, Brazil
关键词
cleft palate; computer simulations; dental technology; morphology; smartphone apps;
D O I
10.1111/ocr.12859
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the performance of smartphone scanning applications (apps) in acquiring 3D meshes of cleft palate models. Secondarily, to validate a machine learning (ML) tool for computing automated presurgical plate (PSP). Materials and Methods: We conducted a comparative analysis of two apps on 15 cleft palate models: five unilateral cleft lip and palate (UCLP), five bilateral cleft lip and palate (BCLP) and five isolated cleft palate (ICP). The scans were performed with and without a mirror to simulate intraoral acquisition. The 3D reconstructions were compared to control reconstructions acquired using a professional intraoral scanner using open- source software. Results: Thirty 3D scans were acquired by each app, totalling 60 scans. The main findings were in the UCLP sample, where the KIRI scans without a mirror (0.22 +/- 0.03 mm) had a good performance with a deviation from the ground truth comparable to the control group (0.14 +/- 0.13 mm) (p p = .653). Scaniverse scans with a mirror showed the lowest accuracy of all the samples. The ML tool was able to predict the landmarks and automatically generate the plates, except in ICP models. KIRI scans' plates showed better performance with (0.22 +/- 0.06 mm) and without mirror (0.18 +/- 0.05 mm), being comparable with controls (0.16 +/- 0.08 mm) (p p = .954 and p = .439, respectively). Conclusions: KIRI Engine performed better in scanning UCLP models without a mirror. The ML tool showed a high capability for morphology recognition and automated PSP generation.
引用
收藏
页码:166 / 174
页数:9
相关论文
共 22 条
[1]   Evaluation of 3D Face-Scan images obtained by stereophotogrammetry and smartphone camera [J].
Akan, Burcin ;
Akan, Ender ;
Sahan, Ahmet Oguz ;
Kalak, Mert .
INTERNATIONAL ORTHODONTICS, 2021, 19 (04) :669-678
[2]   Validity and reliability of three-dimensional modeling of orthodontic dental casts using smartphone-based photogrammetric technology [J].
Al-Rudainy, Dhelal ;
Al-Lami, Hadeel Adel ;
Yang, Liu .
JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2023, 12 (01) :9-14
[3]   A New Frame for Orienting Infants With Cleft Lip and Palate During 3-Dimensional Facial Scanning [J].
Alisha, K. H. ;
Batra, Puneet ;
Raghavan, Sreevatsan ;
Sharma, Karan ;
Talwar, Aditya .
CLEFT PALATE CRANIOFACIAL JOURNAL, 2022, 59 (07) :946-950
[4]   Transforming smiles using an intraoral scanner and face scan application on smartphone [J].
Asutay, Hilal Ciftci ;
Turkyilmaz, Ilser ;
Benli, Merve ;
Martinez, Jacqueline L. .
JOURNAL OF DENTAL SCIENCES, 2022, 17 (03) :1413-1414
[5]   Digital impressions from newborns to preschoolers with cleft lip and palate: A two-centers experience [J].
Benitez, Benito K. ;
Brudnicki, Andrzej ;
Surowiec, Zbigniew ;
Wieprzowski, Lukasz ;
Rasadurai, Abeelan ;
Nalabothu, Prasad ;
Lill, Yoriko ;
Mueller, Andreas A. .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2022, 75 (11) :4233-4242
[6]  
Blender Online Community, 2020, Blender-a 3D modelling and rendering package, P5
[7]   Evaluation of camera settings for photogrammetric reconstruction of humanoid phantoms for EBRT bolus and HDR surface brachytherapy applications [J].
Bridger, Corey A. ;
Douglass, Michael J. J. ;
Reich, Paul D. ;
Santos, Alexandre M. Caraca .
PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (02) :457-471
[8]  
CloudCompare, 2020, CLOUDCOMPARE 3D POIN
[9]   A comparison between stereophotogrammetry and smartphone structured light technology for three-dimensional face scanning [J].
D'Ettorre, Giorgio ;
Farronato, Marco ;
Candida, Ettore ;
Quinzi, Vincenzo ;
Grippaudo, Cristina .
ANGLE ORTHODONTIST, 2022, 92 (03) :358-363
[10]   Smartphone Application as a Low-Cost Alternative for Digitizing Facial Defects: Is It Accurate Enough for Clinical Application? [J].
Elbashti, Mahmoud E. ;
Sumita, Yuka, I ;
Aswehlee, Amel M. ;
Seelaus, Rosemary .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (06) :541-543