Collapse behavior investigation of simple connections for uninsulated composite beams under fires

被引:0
作者
Takagi, Jiro [1 ]
Kobayashi, Yura [1 ]
Oyama, Noboru [1 ]
Azai, Kumpei [1 ]
机构
[1] Tokyo Metropolitan Univ, Grad Sch Urban Environm Sci, Tokyo, Japan
关键词
Steel structure; Fire; Heating and loading experiment; Composite beam; Slab; Large deformation; Collapse; MEMBRANE ACTION; BUILDING STRUCTURES; CONCRETE SLABS;
D O I
10.1016/j.jcsr.2024.108945
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Detailed FEM analysis models were created for steel floor structures including uninsulated beams and slabs. The simulated collapse behavior at elevated temperatures under fires involved the rupture of slab reinforcement around the bolted simple connections of the uninsulated secondary beams. Corresponding to the numerical results, full-scale heating and loading experiments were conducted. The vertical and horizontal loads were applied simulating the behavior of the connection of an uninsulated secondary beam at elevated temperatures. The experiment revealed that the critical collapse behavior around the connection is rupture of slab reinforcement followed by shear failure of the bolts. In the case that slab reinforcement is wire-mesh, the reinforcement may rupture under the out-of-plane flexural deformation during the development process of tension mechanisms associated with large deflection. In the case that deformed reinforcement is used for the slab, deformation capacity against out-of-plane deformation of the slab significantly increased. The collapse load under the tension mechanism was approximately 1.5 times the weight of a standard office floor, even with nearly minimum reinforcement for practical slab design.
引用
收藏
页数:14
相关论文
共 33 条
[1]  
ABAQUS/CAE, 2021, Explicit
[2]  
[Anonymous], 1991, Investigation of Broadgate Phase 8 Fire
[3]   Behaviour of concrete floor slabs at ambient and elevated temperatures [J].
Bailey, C. G. ;
Toh, W. S. .
FIRE SAFETY JOURNAL, 2007, 42 (6-7) :425-436
[4]   Membrane action of slab/beam composite floor systems in fire [J].
Bailey, CG .
ENGINEERING STRUCTURES, 2004, 26 (12) :1691-1703
[5]   Membrane Action of Composite Fibre Concrete Slab in Fire [J].
Bednar, J. ;
Wald, F. ;
Vodicka, J. ;
Kohoutkova, A. .
STEEL STRUCTURES AND BRIDGES 2012 - 23RD CZECH AND SLOVAK INTERNATIONAL CONFERENCE, 2012, 40 :498-503
[6]   Structural fire resistance of partially restrained, partially composite floor beams, II: Modeling [J].
Drury, Michael M. ;
Kordosky, Amy N. ;
Quiel, Spencer E. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 167
[7]  
Duchow M, 2014, 8 INT C STRUCT FIR S, P6
[8]  
European Committee for Standardisation (CEN), 2005, EN 1993-1-2: Eurocode 3 - Design of Steel Structures - Part 1-2: General Rules - Structural Fire Design
[9]  
European Committee for Standardization (CEN), 2004, ENV 1992-1-2
[10]   Robustness of steel-composite building structures subject to localised fire [J].
Fang, C. ;
Izzuddin, B. A. ;
EIghazouli, A. Y. ;
Nethercot, D. A. .
FIRE SAFETY JOURNAL, 2011, 46 (06) :348-363