3D numerical study of axial compression behavior of concrete-filled steel tubular columns from mesoscopic perspective

被引:0
作者
Longfei, Zhang [1 ,2 ,3 ]
Xiaotong, Sun [4 ]
Jie, Hu [2 ,3 ]
Hao, Xie [5 ]
Jiaqi, Zhang [2 ,3 ]
机构
[1] Henan Acad Sci, Inst Chem, Zhengzhou 450046, Peoples R China
[2] China Univ Min & Technol, State Key Lab Geomech & Deep Underground Engn, Beijing 100083, Peoples R China
[3] China Univ Min & Technol, Sch Mech & Civil Engn, Beijing 100083, Peoples R China
[4] Jinan Heavy Ind Grp Co Ltd, Jinan 250109, Peoples R China
[5] Jinan Rail Transit Grp Co Ltd, Jinan 250014, Peoples R China
关键词
Concrete-filled steel tubular; Concrete damaged plasticity; Uniaxial compression; Failure mechanism; Mesostructure; HIGH-STRENGTH CONCRETE; PLASTIC-DAMAGE MODEL; SIMULATION; FAILURE; DESIGN;
D O I
10.1016/j.istruc.2024.106976
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the axial compression behavior of Concrete-Filled Steel Tubular (CFST) short columns from a mesoscopic perspective. Concrete is regarded as a three-phase composite material consisting of aggregates, mortar, and interfacial transition zones (ITZs). The Concrete Damaged Plasticity (CDP) model was employed to simulate the nonlinear mechanical response and fracture characteristics of concrete. Verified against experimental results, the numerical model excels in realistically simulating the uniaxial compression behavior of CFST short columns. Subsequently, factors influencing the macroscopic behavior of CFST short columns were investigated. Results indicate that the random aggregate model adopted for concrete enables a more realistic prediction of the behavior of CFST short columns. Additionally, circular section steel tubes demonstrate a stronger confinement effect compared to square ones. With increasing lateral confinement, the properties of CFST short columns, such as bearing capacity and ductility, are significantly enhanced.
引用
收藏
页数:14
相关论文
共 52 条
  • [1] Abaqus, 2014, Analysis: User's manual
  • [2] [Anonymous], 2003, Concrete-Filled Steel Tubular Structures
  • [3] Cai SH, 2007, Modern Steel Tube Confined Concrete Structures
  • [4] [陈宝春 Chen Baochun], 2017, [土木工程学报, China Civil Engineering Journal], V50, P50
  • [5] Chen BC, 2007, Concrete-filled steel tubular arch bridge
  • [6] Claeson C, 1998, Structural behavior of reinforced high-strength concrete columns
  • [7] Numerical modelling of the axial compressive behaviour of short concrete-filled elliptical steel columns
    Dai, X.
    Lam, D.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (07) : 931 - 942
  • [8] High-strength concrete with different fine aggregate
    Donza, H
    Cabrera, O
    Irassar, EF
    [J]. CEMENT AND CONCRETE RESEARCH, 2002, 32 (11) : 1755 - 1761
  • [9] Numerical simulation of dynamic tensile-failure of concrete at meso-scale
    Du, Xiuli
    Jin, Liu
    Ma, Guowei
    [J]. INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2014, 66 : 5 - 17
  • [10] Design and behaviour of concrete-filled cold-formed stainless steel tube columns
    Ellobody, E
    Young, B
    [J]. ENGINEERING STRUCTURES, 2006, 28 (05) : 716 - 728