Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection

被引:2
|
作者
Akhtarian, Shiva [1 ]
Brar, Satinder Kaur [2 ]
Rezai, Pouya [1 ]
机构
[1] York Univ, Dept Mech Engn, Toronto, ON M3J 1P3, Canada
[2] York Univ, Dept Civil Engn, Toronto, ON M3J 1P3, Canada
来源
BIOSENSORS-BASEL | 2024年 / 14卷 / 09期
基金
加拿大自然科学与工程研究理事会;
关键词
biosensor; bacteria detection; cell-imprinted polymer (CIP); microfluidic; electrochemical sensor; LABEL-FREE;
D O I
10.3390/bios14090445
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The rapid and sensitive detection of bacterial contaminants using low-cost and portable point-of-need (PoN) biosensors has gained significant interest in water quality monitoring. Cell-imprinted polymers (CIPs) are emerging as effective and inexpensive materials for bacterial detection as they provide specific binding sites designed to capture whole bacterial cells, especially when integrated into PoN microfluidic devices. However, improving the sensitivity and detection limits of these sensors remains challenging. In this study, we integrated CIP-functionalized stainless steel microwires (CIP-MWs) into a microfluidic device for the impedimetric detection of E. coli bacteria. The sensor featured two parallel microchannels with three-electrode configurations that allowed simultaneous control and electrochemical impedance spectroscopy (EIS) measurements. A CIP-MW and a non-imprinted polymer (NIP)-MW suspended perpendicular to the microchannels served as the working electrodes in the test and control channels, respectively. Electrochemical spectra were fitted with equivalent electrical circuits, and the charge transfer resistances of both cells were measured before and after incubation with target bacteria. The charge transfer resistance of the CIP-MWs after 30 min of incubation with bacteria was increased. By normalizing the change in charge transfer resistance and analyzing the dose-response curve for bacterial concentrations ranging from 0 to 107 CFU/mL, we determined the limits of detection and quantification as 2 x 102 CFU/mL and 1.4 x 104 CFU/mL, respectively. The sensor demonstrated a dynamic range of 102 to 107 CFU/mL, where bacterial counts were statistically distinguishable. The proposed sensor offers a sensitive, cost-effective, durable, and rapid solution for on-site identification of waterborne pathogens.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Label-free electrochemical impedance spectroscopy biosensor for direct detection of cancer cells based on the interaction between carbohydrate and lectin
    Hu, Yaofang
    Zuo, Peng
    Ye, Bang-Ce
    BIOSENSORS & BIOELECTRONICS, 2013, 43 : 79 - 83
  • [32] A novel electrochemical impedance biosensor based on plasma-polymerized films for detection of biotin
    Deng, Ting
    Cao, Zhong
    Shen, Guoli
    ADVANCED MATERIALS, PTS 1-4, 2011, 239-242 : 1653 - +
  • [33] A Surface-Enhanced Raman Spectroscopy-Based Biosensor for the Detection of Biological Macromolecules: The Case of the Lipopolysaccharide Endotoxin Molecules
    Rusciano, Giulia
    Capaccio, Angela
    Sasso, Antonio
    Capo, Alessandro
    Almuzara, Carlos Murillo
    Staiano, Maria
    D'Auria, Sabato
    Varriale, Antonio
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (15)
  • [34] DNA Hybridization Sensors Based on Electrochemical Impedance Spectroscopy as a Detection Tool
    Park, Jin-Young
    Park, Su-Moon
    SENSORS, 2009, 9 (12) : 9513 - 9532
  • [35] Flatfish vitellogenin detection using optical waveguide lightmode spectroscopy-based immunosensor
    Kim
    Namsow
    Ryu, Hyung-Seok
    Kim, Woo-Yeon
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2007, 17 (09) : 1445 - 1451
  • [36] The Importance of Developing Electrochemical Sensors Based on Molecularly Imprinted Polymers for a Rapid Detection of Antioxidants
    Elhachem, Marie
    Cayot, Philippe
    Abboud, Maher
    Louka, Nicolas
    Maroun, Richard G.
    Bou-Maroun, Elias
    ANTIOXIDANTS, 2021, 10 (03) : 1 - 35
  • [37] Sol-Gel Imprinted Polymers Based Electrochemical Sensor for Paracetamol Recognition and Detection
    Zhu, Anhong
    Xu, Guilin
    Li, Lu
    Yang, Lingling
    Zhou, Hong
    Kan, Xianwen
    ANALYTICAL LETTERS, 2013, 46 (07) : 1132 - 1144
  • [38] Detection of Insulin-Like Growth Factor 1 Based on an Electrochemical Impedance Spectroscopy Sensor
    Ding, Lin
    Zhang, Hongtao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (12): : 11163 - 11170
  • [39] Electrochemical Sensing of Phenylalanine using Polyaniline-Based Molecularly Imprinted Polymers
    Sarangi, Sonia
    Srivastava, Ravishankar
    Gogoi-Tiwari, Jully
    Kar, Rajiv K.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2024, 128 (41) : 10258 - 10271
  • [40] Sensitive Detection of SARS-CoV-2 Variants Using an Electrochemical Impedance Spectroscopy Based Aptasensor
    Kurmangali, Assem
    Dukenbayev, Kanat
    Kanayeva, Damira
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (21)