Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection

被引:2
|
作者
Akhtarian, Shiva [1 ]
Brar, Satinder Kaur [2 ]
Rezai, Pouya [1 ]
机构
[1] York Univ, Dept Mech Engn, Toronto, ON M3J 1P3, Canada
[2] York Univ, Dept Civil Engn, Toronto, ON M3J 1P3, Canada
来源
BIOSENSORS-BASEL | 2024年 / 14卷 / 09期
基金
加拿大自然科学与工程研究理事会;
关键词
biosensor; bacteria detection; cell-imprinted polymer (CIP); microfluidic; electrochemical sensor; LABEL-FREE;
D O I
10.3390/bios14090445
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The rapid and sensitive detection of bacterial contaminants using low-cost and portable point-of-need (PoN) biosensors has gained significant interest in water quality monitoring. Cell-imprinted polymers (CIPs) are emerging as effective and inexpensive materials for bacterial detection as they provide specific binding sites designed to capture whole bacterial cells, especially when integrated into PoN microfluidic devices. However, improving the sensitivity and detection limits of these sensors remains challenging. In this study, we integrated CIP-functionalized stainless steel microwires (CIP-MWs) into a microfluidic device for the impedimetric detection of E. coli bacteria. The sensor featured two parallel microchannels with three-electrode configurations that allowed simultaneous control and electrochemical impedance spectroscopy (EIS) measurements. A CIP-MW and a non-imprinted polymer (NIP)-MW suspended perpendicular to the microchannels served as the working electrodes in the test and control channels, respectively. Electrochemical spectra were fitted with equivalent electrical circuits, and the charge transfer resistances of both cells were measured before and after incubation with target bacteria. The charge transfer resistance of the CIP-MWs after 30 min of incubation with bacteria was increased. By normalizing the change in charge transfer resistance and analyzing the dose-response curve for bacterial concentrations ranging from 0 to 107 CFU/mL, we determined the limits of detection and quantification as 2 x 102 CFU/mL and 1.4 x 104 CFU/mL, respectively. The sensor demonstrated a dynamic range of 102 to 107 CFU/mL, where bacterial counts were statistically distinguishable. The proposed sensor offers a sensitive, cost-effective, durable, and rapid solution for on-site identification of waterborne pathogens.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Towards Electrochemical Sensor Based on Molecularly Imprinted Polypyrrole for the Detection of Bacteria-Listeria monocytogenes
    Liustrovaite, Viktorija
    Pogorielov, Maksym
    Boguzaite, Raimonda
    Ratautaite, Vilma
    Ramanaviciene, Almira
    Pilvenyte, Greta
    Holubnycha, Viktoriia
    Korniienko, Viktoriia
    Diedkova, Kateryna
    Viter, Roman
    Ramanavicius, Arunas
    POLYMERS, 2023, 15 (07)
  • [22] Detection of pathogenic Bacteria by Electrochemical Impedance Spectroscopy: Influence of the immobilization strategies on the sensor performance
    Barreiros dos Santos, M.
    Sporer, C.
    Sanvicens, N.
    Pascual, N.
    Errachid, A.
    Martinez, E.
    Marco, M. -P.
    Teixeira, V.
    Samiter, J.
    PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 1291 - +
  • [23] A novel electrochemical sensor based on molecularly imprinted polymers for caffeine recognition and detection
    Kan, Xianwen
    Liu, Tingting
    Li, Chen
    Zhou, Hong
    Xing, Zonglan
    Zhu, Anhong
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (10) : 3207 - 3213
  • [24] Selective electrochemical determination based on magnetic molecularly imprinted polymers for albumin detection
    Leepheng, Piyawan
    Limthin, Dalawan
    Onlaor, Korakot
    Tunhoo, Benchapol
    Thiwawong, Thutiyaporn
    Suramitr, Songwut
    Phromyothin, Darinee
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2022, 61 (SD)
  • [25] Electrochemical sensor for bisphenol A detection based on molecularly imprinted polymers and gold nanoparticles
    Jiadong Huang
    Xiuming Zhang
    Su Liu
    Qing Lin
    Xiaorui He
    Xianrong Xing
    Wenjing Lian
    Journal of Applied Electrochemistry, 2011, 41 : 1323 - 1328
  • [26] Label Free Detection of L-Glutamate Using Microfluidic Based Thermal Biosensor
    Kopparthy, Varun Lingaiah
    Tangutooru, Siva Mahesh
    Guilbeau, Eric J.
    BIOENGINEERING-BASEL, 2015, 2 (01): : 2 - 14
  • [27] A novel electrochemical sensor based on molecularly imprinted polymers for caffeine recognition and detection
    Xianwen Kan
    Tingting Liu
    Chen Li
    Hong Zhou
    Zonglan Xing
    Anhong Zhu
    Journal of Solid State Electrochemistry, 2012, 16 : 3207 - 3213
  • [28] Electrochemical sensor for bisphenol A detection based on molecularly imprinted polymers and gold nanoparticles
    Huang, Jiadong
    Zhang, Xiuming
    Liu, Su
    Lin, Qing
    He, Xiaorui
    Xing, Xianrong
    Lian, Wenjing
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2011, 41 (11) : 1323 - 1328
  • [29] Microfluidic Impedance Biosensor Chips Using Sensing Layers Based on DNA-Based Self-Assembled Monolayers for Label-Free Detection of Proteins
    Alsabbagh, Khaled
    Hornung, Tim
    Voigt, Achim
    Sadir, Sahba
    Rajabi, Taleieh
    Lange, Kerstin
    BIOSENSORS-BASEL, 2021, 11 (03):
  • [30] Whole cell based microcontact imprinted capacitive biosensor for the detection of Escherichia coli
    Idil, Neslihan
    Hedstrom, Martin
    Denizli, Adil
    Mattiasson, Bo
    BIOSENSORS & BIOELECTRONICS, 2017, 87 : 807 - 815