Comparing mechanical ventilation control strategies for indoor air quality: Monitoring and simulation results of a school building in northern Italy

被引:6
|
作者
Chiesa, Giacomo [1 ]
Vigliotti, Manuela [2 ]
机构
[1] Politecn Torino, Dept Architecture & Design, Turin, Italy
[2] Politecn Torino, ICT4SS, Cozzo, Italy
关键词
Indoor Air Quality; Control Logic; Detached Mechanical Ventilation; Smart Building; School Building; PREDYCE; DEMAND-CONTROLLED VENTILATION; NATURAL VENTILATION; ENERGY;
D O I
10.1016/j.enbuild.2024.114665
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Demand-controlled ventilation systems and carbon dioxide monitoring are critical to ensure indoor air quality (IAQ) comfort conditions. Their importance has become significantly more evident since the COVID-19 pandemic crisis. Control strategies for mechanical ventilation based on CO2 concentration are commonly used, although they are rarely applied in Italian and other Southern European country schools. Moreover, optimised ventilation systems can help maintain indoor air quality while reducing energy consumption for heating (i.e. exploiting heat recovery). The proposed paper aims to compare different remote-control strategies to manage three detached mechanical ventilation units (DMV) installed in a junior-high-school demo building in Torre Pellice (Northwest Italy), monitored with room detail since April 2021. Eight IAQ control logics are analysed considering both in situ tests, handling DMV accordingly to room sensors, and simulation tests using the Energy Management System of EnergyPlus in the neutral season. All different solutions are compared by considering air quality, temperature, and energy need indicators. Additionally, a yearly energy verification via hourly simplified analyses is performed by considering fan consumption and energy conservation. Threshold-based control logics result to be more effective than time-dependent ones, while all cases guarantee very high IAQ levels, although energy savings are limited. The choice of the correct control threshold(s) is site-dependent being influenced by user local habits.
引用
收藏
页数:20
相关论文
共 11 条
  • [1] Optimising Mechanical Ventilation for Indoor Air Quality and Thermal Comfort in a Mediterranean School Building
    Rizzo, Krista
    Camilleri, Mark
    Gatt, Damien
    Yousif, Charles
    SUSTAINABILITY, 2024, 16 (02)
  • [2] Effects of Ventilation Improvement on Measured and Perceived Indoor Air Quality in a School Building with a Hybrid Ventilation System
    Vornanen-Winqvist, Camilla
    Salonen, Heidi
    Jarvi, Kati
    Andersson, Maria A.
    Mikkola, Raimo
    Marik, Tanis
    Kredics, Laszlo
    Kurnitski, Jarek
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (07)
  • [3] Year long monitoring of indoor air quality and ventilation in school classrooms in Victoria, Australia
    Rajagopalan, Priyadarsini
    Andamon, Mary Myla
    Woo, Jin
    ARCHITECTURAL SCIENCE REVIEW, 2022, 65 (01) : 1 - 13
  • [4] Ventilation Positive Pressure Intervention Effect on Indoor Air Quality in a School Building with Moisture Problems
    Vornanen-Winqvist, Camilla
    Jarvi, Kati
    Toomla, Sander
    Ahmed, Kaiser
    Andersson, Maria A.
    Mikkola, Raimo
    Marik, Tamas
    Kredics, Laszlo
    Salonen, Heidi
    Kurnitski, Jarek
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (02)
  • [5] Analysis of Building Retrofit, Ventilation, and Filtration Measures for Indoor Air Quality in a Real School Context: A Case Study in Korea
    Sung, Ho Jin
    Kim, Sean Hay
    Kim, Hyunsuk
    BUILDINGS, 2023, 13 (04)
  • [6] Mechanical, natural and hybrid ventilation systems in different building types: Energy and indoor air quality analysis
    Tognon, Giacomo
    Marigo, Marco
    De Carli, Michele
    Zarrella, Angelo
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [7] Energy implications of meeting indoor air quality and thermal comfort standards in Mediterranean schools using natural and mechanical ventilation strategies
    Maiques, M.
    Tarragona, J.
    Gangolells, M.
    Casals, M.
    ENERGY AND BUILDINGS, 2025, 328
  • [8] Comparison of the indoor air quality in an office operating with natural or mechanical ventilation using short-term intensive pollutant monitoring
    Montgomery, James F.
    Storey, Stefan
    Bartlett, Karen
    INDOOR AND BUILT ENVIRONMENT, 2015, 24 (06) : 777 - 787
  • [9] Monitoring and modelling indoor air quality and ventilation in classrooms within a purpose-designed naturally ventilated school
    Kolokotroni, M
    Ge, YT
    Katsoulas, D
    INDOOR AND BUILT ENVIRONMENT, 2002, 11 (06) : 316 - 326
  • [10] Restaurant managers knowledge and intention to improve building ventilation and indoor air quality using control measures in a middle-income country
    Lee, Jia Yin
    Aghamohammadi, Nasrin
    BUILDING AND ENVIRONMENT, 2023, 244