Optimized Design of High-Temperature Resistant Air-Coupled Ultrasonic Transducer (ACUT) Based on Single Acoustic Matching Layer

被引:2
|
作者
Zhang, Liang [1 ,2 ]
Xu, Xinhu [1 ]
Wang, Xiaojie [3 ]
Li, Lei [2 ]
Guo, Hulin
Kong, Lingcai [1 ]
Shi, Wanglong [1 ]
Zang, Jinliang [1 ,2 ]
机构
[1] Natl Inst Metrol, Thermometry Div, Beijing 100029, Peoples R China
[2] Zhengzhou Inst Metrol, Zhengzhou 450001, Peoples R China
[3] Hebei Univ, Sch Qual & Tech Supervis, Baoding 071002, Peoples R China
关键词
Air-coupled ultrasonic transducer (AUCT); flow rate calibration; high-temperature; matching layer; sensitivity; SOUND-VELOCITY; PRESSURE; SIGNALS; GAS;
D O I
10.1109/JSEN.2024.3434449
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A high-temperature resistant air-coupled ultrasonic transducer (ACUT) was optimally designed with a single acoustic matching layer structure. The matching layer was prepared with an organosilicon substrate instead of traditional epoxy resin mixed with hollow glass microspheres. Acoustic performance tests showed that the matching layer achieved an acoustic impedance of 1.06 MRayl and an acoustic attenuation coefficient of 0.47 dB/mm. The ACUT was clamped with a prestressed bolt structure instead of an adhesive layer and encapsulated with a metal shell. Mechanical performance was tested before and after encapsulation, which resulted in varying degrees of reduction in mechanical quality factor and resonant frequency. The acoustic performance of the ACUT was compared to commercial transducers, and the results indicated 2.72 and 1.88 dB higher transmitting and receiving sensitivities than those of commercial transducers. The received amplitude increased by an additional 22% by adding an electrical impedance matching circuit between the excitation source and the transmitting transducer. High-temperature experiments revealed a linear decrease in the received signal amplitude with increasing temperature. The ACUT is finally calibrated for ambient flow rate calibration and high-temperature flow velocity calibration, respectively. The ambient flow rate calibration exhibited an error of only 1.9%, while the high-temperature flow velocity calibration demonstrated that temperature has a minimal impact on the precision of the ACUT.
引用
收藏
页码:27340 / 27351
页数:12
相关论文
共 50 条
  • [41] Generating High-Quality Air-Coupled Ultrasonic Images for Wooden Material Characterization by Single Image Super-Resolution
    Lin, Lujun
    Fang, Yiming
    Du, Xiaochen
    Zhou, Zhu
    INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 2020, 34 (03)
  • [42] High-SPL Air-Coupled Piezoelectric Micromachined Ultrasonic Transducers Based on 36% ScAlN Thin-Film
    Kusano, Yuri
    Ishii, Itaru
    Kamiya, Tatsuya
    Teshigahara, Akihiko
    Luo, Guo-Lun
    Horsley, David A.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (09) : 1488 - 1496
  • [43] Application of Adaptive Filtering Based on Variational Mode Decomposition for High-Temperature Electromagnetic Acoustic Transducer Denoising
    Zhao, Shuaijie
    Zhou, Jinjie
    Liu, Yao
    Zhang, Jitang
    Cui, Jie
    SENSORS, 2022, 22 (18)
  • [44] A Method of Electrodeless Contacting of a Piezo Material in a High-Temperature Resistant Ultrasonic Transducer for Use in the Immersion Technique in Electrically Conductive Liquids
    Shapovalov, O.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2022, 65 (01) : 175 - 178
  • [45] A Method of Electrodeless Contacting of a Piezo Material in a High-Temperature Resistant Ultrasonic Transducer for Use in the Immersion Technique in Electrically Conductive Liquids
    O. Shapovalov
    Instruments and Experimental Techniques, 2022, 65 : 175 - 178
  • [46] Detection Method for Cavity Defects in Ballastless Track Structures of High-Speed Railways Based on Air-Coupled Ultrasonic Lamb Waves
    Zhu Wenfa
    Shao Wei
    Chen Xingjie
    Meng Xiangzhen
    Zhang Haiyan
    SAE INTERNATIONAL JOURNAL OF VEHICLE DYNAMICS STABILITY AND NVH, 2019, 3 (02): : 143 - 149
  • [47] Model and Design of High-Temperature Ultrasonic Sensors for Detecting Position and Temperature Based on Iron-Based Magnetostrictive Wires
    Wang, Qian
    Li, Mingming
    Niu, Xiaodong
    Liu, Mengfei
    Wang, Bowen
    IEEE SENSORS JOURNAL, 2021, 21 (23) : 26868 - 26877
  • [48] Acoustic stability and self-healing mechanism of nano-Ag coupled transducer for long-term high-temperature monitoring
    Gu, Yiqing
    Feng, Yue
    Jia, Jiuhong
    Tu, Shan-Tung
    APPLIED ACOUSTICS, 2025, 235
  • [49] A Spherically-Shaped PZT Thin Film Ultrasonic Transducer with an Acoustic Impedance Gradient Matching Layer Based on a Micromachined Periodically Structured Flexible Substrate
    Feng, Guo-Hua
    Liu, Wei-Fan
    SENSORS, 2013, 13 (10): : 13543 - 13559
  • [50] Multi-layer polymer-metal structures for acoustic impedance matching in high-frequency broadband ultrasonic transducers design
    Yang, Xinyu
    Fei, Chunlong
    Xinhaosun
    Hou, Shang
    Chen, Jun
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1808 - 1811