Optimized Design of High-Temperature Resistant Air-Coupled Ultrasonic Transducer (ACUT) Based on Single Acoustic Matching Layer

被引:2
|
作者
Zhang, Liang [1 ,2 ]
Xu, Xinhu [1 ]
Wang, Xiaojie [3 ]
Li, Lei [2 ]
Guo, Hulin
Kong, Lingcai [1 ]
Shi, Wanglong [1 ]
Zang, Jinliang [1 ,2 ]
机构
[1] Natl Inst Metrol, Thermometry Div, Beijing 100029, Peoples R China
[2] Zhengzhou Inst Metrol, Zhengzhou 450001, Peoples R China
[3] Hebei Univ, Sch Qual & Tech Supervis, Baoding 071002, Peoples R China
关键词
Air-coupled ultrasonic transducer (AUCT); flow rate calibration; high-temperature; matching layer; sensitivity; SOUND-VELOCITY; PRESSURE; SIGNALS; GAS;
D O I
10.1109/JSEN.2024.3434449
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A high-temperature resistant air-coupled ultrasonic transducer (ACUT) was optimally designed with a single acoustic matching layer structure. The matching layer was prepared with an organosilicon substrate instead of traditional epoxy resin mixed with hollow glass microspheres. Acoustic performance tests showed that the matching layer achieved an acoustic impedance of 1.06 MRayl and an acoustic attenuation coefficient of 0.47 dB/mm. The ACUT was clamped with a prestressed bolt structure instead of an adhesive layer and encapsulated with a metal shell. Mechanical performance was tested before and after encapsulation, which resulted in varying degrees of reduction in mechanical quality factor and resonant frequency. The acoustic performance of the ACUT was compared to commercial transducers, and the results indicated 2.72 and 1.88 dB higher transmitting and receiving sensitivities than those of commercial transducers. The received amplitude increased by an additional 22% by adding an electrical impedance matching circuit between the excitation source and the transmitting transducer. High-temperature experiments revealed a linear decrease in the received signal amplitude with increasing temperature. The ACUT is finally calibrated for ambient flow rate calibration and high-temperature flow velocity calibration, respectively. The ambient flow rate calibration exhibited an error of only 1.9%, while the high-temperature flow velocity calibration demonstrated that temperature has a minimal impact on the precision of the ACUT.
引用
收藏
页码:27340 / 27351
页数:12
相关论文
共 50 条
  • [31] Numerical and experimental analysis of focused air-coupled ultrasonic transducer based on cross-linked polypropylene film
    Li, Feng
    Zhang, Yuxuan
    Pan, Yongdong
    Zhao, Jinfeng
    Zhang, Xiaoqing
    AIP ADVANCES, 2022, 12 (03)
  • [32] Investigation of high-temperature ultrasonic transducer design using lithium niobate piezocomposite
    Kirk, K. J.
    Hou, R.
    Schmarje, N.
    Pragada, N. M.
    Torbay, L.
    Hutson, D.
    INSIGHT, 2015, 57 (04) : 193 - 199
  • [33] Design of High Temperature Resistant Electromagnetic Acoustic Transducer With Double Coil Structure
    Zhai G.
    Liang B.
    Deng C.
    Jiang C.
    Wang S.
    Li Z.
    1600, Chinese Society for Electrical Engineering (41): : 3943 - 3950
  • [34] Air-Coupled Ultrasonic Transducers Based on an Application of the PMN-32%PT Single Crystals
    Kazys, R.
    Sliteris, R.
    Sestoke, J.
    Vladisauskas, A.
    FERROELECTRICS, 2015, 480 (01) : 85 - 91
  • [35] Investigation of an air-coupled transducer with a closed-cell material matching strategy and an optimization design considering the electrical input impedance
    Wu, Qiao
    Chen, Qiuying
    Lian, Guoxuan
    Wang, Xiaomin
    Song, Xiaochun
    Zhang, Xu
    ULTRASONICS, 2021, 115
  • [36] HIGH-TEMPERATURE ACOUSTIC TRANSDUCER BASED ON LANTHANUM-GALLIUM TANTALATE PIEZOCRYSTALS
    Dan'kov, I. A.
    Ivannikov, V. I.
    Tokarev, E. F.
    Shekhovtsov, V. N.
    MEASUREMENT TECHNIQUES, 2010, 53 (01) : 23 - 27
  • [37] High-temperature acoustic transducer based on lanthanum-gallium tantalate piezocrystals
    I. A. Dan’kov
    V. I. Ivannikov
    E. F. Tokarev
    V. N. Shekhovtsov
    Measurement Techniques, 2010, 53 : 23 - 27
  • [38] High-performance ultrasonic transducer based on PZT piezoelectric ceramic for high-temperature NDE
    Zou, Kai
    Yue, Qingwen
    Li, Jianan
    Zhang, Wenbin
    Liang, Ruihong
    Zhou, Zhiyong
    ULTRASONICS, 2023, 132
  • [39] Air-coupled ultrasonic transducer based on lead-free piezoceramics prepared by digital light processing 3D printing
    Zhou, Xinyi
    Ma, Weigang
    Gao, Huayun
    Wang, Chuanmin
    Samarth, Chanatip
    Kongparakul, Suwadee
    Tran, Nguyen-Minh-An
    Wang, Junfeng
    Liu, Xiaotao
    Tan, Hua
    Zhang, Haibo
    ULTRASONICS, 2024, 143
  • [40] High-temperature piezoelectric ultrasonic transducer based on BiScO3-PbTiO3 ceramics
    Hu, Liqing
    Fu, Liwen
    Ren, Xiaodan
    Zheng, Shuguang
    Wang, Sanhong
    Xu, Zhuo
    Yan, Yongke
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 362