Optimized Design of High-Temperature Resistant Air-Coupled Ultrasonic Transducer (ACUT) Based on Single Acoustic Matching Layer

被引:2
|
作者
Zhang, Liang [1 ,2 ]
Xu, Xinhu [1 ]
Wang, Xiaojie [3 ]
Li, Lei [2 ]
Guo, Hulin
Kong, Lingcai [1 ]
Shi, Wanglong [1 ]
Zang, Jinliang [1 ,2 ]
机构
[1] Natl Inst Metrol, Thermometry Div, Beijing 100029, Peoples R China
[2] Zhengzhou Inst Metrol, Zhengzhou 450001, Peoples R China
[3] Hebei Univ, Sch Qual & Tech Supervis, Baoding 071002, Peoples R China
关键词
Air-coupled ultrasonic transducer (AUCT); flow rate calibration; high-temperature; matching layer; sensitivity; SOUND-VELOCITY; PRESSURE; SIGNALS; GAS;
D O I
10.1109/JSEN.2024.3434449
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A high-temperature resistant air-coupled ultrasonic transducer (ACUT) was optimally designed with a single acoustic matching layer structure. The matching layer was prepared with an organosilicon substrate instead of traditional epoxy resin mixed with hollow glass microspheres. Acoustic performance tests showed that the matching layer achieved an acoustic impedance of 1.06 MRayl and an acoustic attenuation coefficient of 0.47 dB/mm. The ACUT was clamped with a prestressed bolt structure instead of an adhesive layer and encapsulated with a metal shell. Mechanical performance was tested before and after encapsulation, which resulted in varying degrees of reduction in mechanical quality factor and resonant frequency. The acoustic performance of the ACUT was compared to commercial transducers, and the results indicated 2.72 and 1.88 dB higher transmitting and receiving sensitivities than those of commercial transducers. The received amplitude increased by an additional 22% by adding an electrical impedance matching circuit between the excitation source and the transmitting transducer. High-temperature experiments revealed a linear decrease in the received signal amplitude with increasing temperature. The ACUT is finally calibrated for ambient flow rate calibration and high-temperature flow velocity calibration, respectively. The ambient flow rate calibration exhibited an error of only 1.9%, while the high-temperature flow velocity calibration demonstrated that temperature has a minimal impact on the precision of the ACUT.
引用
收藏
页码:27340 / 27351
页数:12
相关论文
共 50 条
  • [1] Acoustic and rheological characterization of hollow glass microsphere composite for development of optimized air-coupled ultrasonic matching layer
    Kang, Chung-Mo
    Baek, Yong-joo
    Jeong, Ji-Young
    Sim, Jongkeun
    Gwak, Eun-Ji
    Je, Tae-Jin
    Choi, Doo-Sun
    Kim, Gyu Man
    Han, Jun Sae
    CERAMICS INTERNATIONAL, 2022, 48 (21) : 32036 - 32048
  • [2] Design of air-coupled capacitive micromachined ultrasonic transducer
    Zhang, Hui
    Li, Zhi
    Zheng, Guanru
    Zeng, Zhoumo
    Shengxue Xuebao/Acta Acustica, 2019, 44 (01): : 116 - 124
  • [3] A new design of ultrasonic air-coupled ribbon transducer
    McIntyre, CS
    Hutchins, DA
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 1029 - 1032
  • [4] Air-coupled ultrasonic tomographic imaging of high-temperature flames
    Gan, TH
    Hutchins, DA
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (09) : 1214 - 1218
  • [5] Study on Acoustic Field of Air-coupled Ultrasonic Transducer in Frequency Domain
    Li J.
    Li L.
    Deng Y.
    Bogdan P.
    Chen F.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2019, 55 (10): : 10 - 16
  • [6] New type of matching layer for air-coupled ultrasonic transducers
    Toda, M
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (07) : 972 - 979
  • [7] Study on the high power air-coupled ultrasonic compound transducer
    Lin, Shuyu
    ULTRASONICS, 2006, 44 : E545 - E548
  • [8] Air-coupled capacitive micromachined ultrasonic transducer for temperature field reconstruction
    Zhang, Hui
    Ma, Yongshuai
    Li, Shaojie
    Liu, Si
    Wang, Junjie
    Wang, Zhuochen
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [9] Design, fabrication and characterization of Emfi-based ferroelectret air-coupled ultrasonic transducer
    Tang, Jianying
    Tong, Likun
    Xiang, Yanxun
    Qiu, Xunlin
    Deng, Mingxi
    Xuan, Fuzhen
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 296 : 52 - 60
  • [10] Investigation of acoustic field calculation and measurement method for air-coupled ultrasonic transducer
    Kong, Tao
    Xu, Chunguang
    Zhang, Yuntao
    Xu, Hanhui
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2011, 47 (22): : 19 - 24