Comparison of robotic system and dynamic navigation for zygomatic implant placement: An in vitro study

被引:1
|
作者
Guo, Houzuo [1 ]
Jiang, Xi [1 ]
Lin, Ye [1 ]
机构
[1] Peking Univ, Sch & Hosp Stomatol, Dept Oral Implantol, 22 Zhongguancun South St, Beijing 10081, Peoples R China
关键词
Zygomatic implant; Robotic system; Dynamic navigation system; Surgical accuracy; In vitro study; Maxillary atrophy rehabilitation; ACCURACY; MANAGEMENT; BONE; REHABILITATION; SURGERY; MAXILLA; ATROPHY;
D O I
10.1016/j.jdent.2024.105329
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the accuracy of robotic and dynamic navigation systems in assisting zygomatic implant (ZI) using an in vitro model experiment. Methods: Preoperative cone-beam computed tomography (CBCT) images of patients who underwent ZI treatment between 2011 and 2023 were collected from local databases. Corresponding three-dimensional resin models were printed and assigned to two groups: the robotic and dynamic navigation system groups. Following preoperative plans, ZIs were placed in the models with the assistance of either a robotic or dynamic navigation system. Deviations in the in vitro navigation surgery were measured and compared between the groups. Results: A total of 110 ZIs were placed in 56 models, with 55 ZIs in each group. No significant differences were observed in entry and angle deviations between the groups (p>0.05). However, the exit deviation in the robotic system group (2.39+1.24 mm) was larger than that in the dynamic navigation group (1.83+1.25 mm) (p<0.05). On the exit side, the Z-axis deviation in the robotic group (left: -0.28+1.43 mm, right: -0.21+1.30 mm) was smaller than that in the dynamic navigation group (left: 0.76+1.11 mm, right: 0.85+1.52 mm) (p<0.05), while no significant differences were found in X- and Y-axis deviations (p>0.05). Conclusions: Compared with the dynamic navigation system, the robotic system can effectively prevent ZI overextension. However, its accuracy on the exit side is slightly lower than that of the dynamic navigation system. Clinical Significance: This preliminary in vitro study showed that the accuracy of the robotic system was slightly inferior to that of the dynamic navigation system in terms of exit deviation when used in ZI placement. Further clinical studies are required to confirm these findings.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Navigation System Approach in Zygomatic Implant Technique
    Gasparini, Giulio
    Boniello, Roberto
    Lafori, Andreina
    De Angelis, Paolo
    Del Deo, Vito
    Moro, Alessandro
    Saponaro, Gianmarco
    Pelo, Sandro
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (01) : 250 - 251
  • [22] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Chen, Jianping
    Bai, Xiaolei
    Ding, Yude
    Shen, Liheng
    Sun, Xin
    Cao, Ruijue
    Yang, Fan
    Wang, Linhong
    BMC ORAL HEALTH, 2023, 23 (01)
  • [23] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Jianping Chen
    Xiaolei Bai
    Yude Ding
    Liheng Shen
    Xin Sun
    Ruijue Cao
    Fan Yang
    Linhong Wang
    BMC Oral Health, 23
  • [24] Comparison of the accuracy of dental implant placement using dynamic and augmented reality-based dynamic navigation: An in vitro study
    Tao, Baoxin
    Fan, Xingqi
    Wang, Feng
    Chen, Xiaojun
    Shen, Yihan
    Wu, Yiqun
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (01) : 196 - 202
  • [25] Combined static and dynamic computer-guided surgery for prosthetically driven zygomatic implant placement
    Du, Chenlin
    Peng, Pei
    Guo, Xiaodong
    Wu, Yunshu
    Zhang, Zeyu
    Hao, Linke
    Zhang, Zongjiu
    Xiong, Jingyu
    JOURNAL OF DENTISTRY, 2025, 152
  • [26] Accuracy of implant placement via dynamic navigation and autonomous robotic computer-assisted implant surgery methods: A retrospective study
    Zhang, Sihui
    Cai, Qin
    Chen, Weiyi
    Lin, Yuxuan
    Gao, Yan
    Wu, Dong
    Chen, Jiang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (02) : 220 - 229
  • [27] A retrospective study of dynamic navigation system-assisted implant placement
    Lijuan Ma
    Mingjun Ye
    Mingle Wu
    Xiaolei Chen
    Shan Shen
    BMC Oral Health, 23
  • [28] Accuracy of a Novel Robot-Assisted System and Dynamic Navigation System for Dental Implant Placement: A Clinical Retrospective Study
    Chen, Jianping
    Ding, Yude
    Cao, Ruijue
    Zheng, Yuchen
    Shen, Liheng
    Wang, Linhong
    Yang, Fan
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [29] Real-Time Surgical Navigation System for the Placement of Zygomatic Implants with Severe Bone Deficiency
    Hung, Kuofeng
    Huang, Wei
    Wang, Feng
    Wu, Yiqun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (06) : 1444 - 1449
  • [30] Dynamic Navigation System for Immediate Implant Placement in the Maxillary Aesthetic Region
    Battista, Eric
    Gasparro, Roberta
    Cacciola, Maria
    Sammartino, Gilberto
    Marenzi, Gaetano
    APPLIED SCIENCES-BASEL, 2022, 12 (11):