Seismic Performance of Cross-Shaped Partially Encased Steel-Concrete Composite Columns: Experimental and Numerical Investigations

被引:2
作者
Xu, Qiuyu [1 ,2 ,3 ]
Liu, Yong [1 ,2 ,3 ]
Wang, Jingfeng [3 ]
机构
[1] China Earthquake Adm, Inst Engn Mech, Key Lab Earthquake Engn & Engn Vibrat, Harbin 150076, Peoples R China
[2] Minist Emergency Management, Key Lab Earthquake Disaster Mitigat, Harbin 150076, Peoples R China
[3] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Peoples R China
基金
中国国家自然科学基金;
关键词
partially encased steel-concrete composite columns; cross-shaped; seismic performance; experimental investigation; finite element analysis; BEHAVIOR; VIBRATION; STRENGTH; SUBJECT; BEAMS; MODEL;
D O I
10.3390/buildings14071932
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Special-shaped partially encased steel-concrete composite (PEC) columns could not only improve the aesthetic effect and room space use efficiency, but also exhibit good mechanical performance under static load when used in multi-story residential and office buildings. However, research on the seismic performance of special-shaped PEC columns is insufficient and urgently needed. To investigate the seismic performance of cross-shaped partially encased steel-concrete composite (CPEC) columns, three CPEC columns were designed and tested under combined constant axial load and lateral cyclic load. The test results show that the CPEC columns had good load capacity and ductility, and that the columns failed because of concrete crushing and steel flange buckling after the yielding of the steel flange. The plump hysteresis loops indicated that the CPEC column also had good energy dissipation capacity. Due to the constraint of hydraulic jacks, increasing the load ratio would decrease the effective length, thereby increasing the load capacity of the CPEC column and decreasing the ductility. A finite element model was also established to simulate the response of the CPEC columns, and the simulated results agree well with the experimental results. Thereafter, an extensive parametric analysis was performed to study the influences of different parameters on the seismic performance of CPEC columns. For the CPEC column with an ideal hinged boundary condition at the top, its lateral load capacity gradually decreases with the growth of the load ratio and link spacing and increases with the rise of the steel yield strength, concrete compressive strength, flange and web thickness, and sectional aspect ratio. This research could provide a basis for future theoretical analyses and engineering application.
引用
收藏
页数:22
相关论文
共 41 条
[1]  
[Anonymous], 2021, GB/T 228.1-2021
[2]  
[Anonymous], 2004, EN 1994-1-1
[3]  
[Anonymous], 2010, Code for design of concrete structures
[4]  
[Anonymous], 2019, GB/T 50081-2019
[5]  
[Anonymous], 2015, JGJ 340-2015
[6]   Finite-element modeling of partially encased composite columns using the dynamic explicit method [J].
Begum, Mahbuba ;
Driver, Robert G. ;
Elwi, Alaa E. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2007, 133 (03) :326-334
[7]   SEISMIC RESISTANCE OF COMPOSITE BEAM-COLUMNS IN MULTISTORY STRUCTURES .2. ANALYTICAL MODEL AND DISCUSSION OF RESULTS [J].
BRODERICK, BM ;
ELNASHAI, AS .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1994, 30 (03) :231-258
[8]   Test and Numerical Simulation of Partially Encased Composite Columns Subject to Axial and Cyclic Horizontal Loads [J].
Chen, Yiyi ;
Wang, Tuo ;
Yang, Jing ;
Zhao, Xianzhong .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2010, 10 (04) :385-393
[9]   Experimental research and finite element analysis on seismic behavior of square reinforced concrete columns with four interlocking spirals [J].
Chen, Zongping ;
Chen, Jianwei ;
Jiang, Xiangshan ;
Mo, Linlin .
STRUCTURES, 2022, 39 :1-16
[10]   Finite element modelling and design of partially encased composite columns [J].
Chicoine, T ;
Tremblay, R ;
Massicotte, B .
STEEL & COMPOSITE STRUCTURES, 2002, 2 (03) :171-194