Effects of the application protocol and bonding strategy of the universal adhesive on dentin previously impregnated with bioceramic sealer

被引:0
作者
Barros, Antonia Patricia Oliveira [1 ]
Costa, Joatan Lucas de Sousa Gomes
Monteiro, Jardel Camilo do Carmo [1 ,2 ]
Galvani, Lucas David [3 ]
de Andrade, Marcelo Ferrarezi [1 ]
Saad, Jose Roberto Cury [1 ]
Kuga, Milton Carlos [1 ]
机构
[1] Sao Paulo State Univ, Araraquara Dent Sch, Dept Operat Dent, Araraquara, SP, Brazil
[2] Univ Fed Minas Gerais, Dept Restorat Dent, Belo Horizonte, MG, Brazil
[3] Sao Paulo State Univ, Araraquara Dent Sch, Dept Dent Mat & Prosthet, Araraquara, SP, Brazil
关键词
Bond strength; Failure modes; Protocols; Bioceramic Sealer; Root canal filling material; STRENGTH; SYSTEMS; IMPROVE;
D O I
10.1016/j.ijadhadh.2024.103765
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Purpose: To evaluate the effects of the application of universal adhesive with manual brush (MB) or rotary brush (RB), in the etch-and-rinse (ER) or self-etching (SE) strategy, on the bond strength, adhesive layer thickness, and adhesive failure pattern to dentin impregnated with bioceramic sealer, at 24 h and 1 year. Materials and methods: Eighty-eight bovine incisor crowns were impregnated with bioceramic sealer was kept for 15 min and cleaned with cotton soaked in distilled water. They were then divided into four groups (n = 22): ERMB, ER-RB, SE-MB, SE-RB. Subsequently, the specimens were restored with Filtek Z-250 resin. The adhesive layer thickness was individually analyzed using laser confocal microscope. Bond strength was assessed through microtensile testing, and the failure pattern was examined using a stereomicroscope. Data were analyzed by oneway ANOVA/Tukey 's tests ( alpha = 0.05). Results: The adhesive layer thickness provided by ER-MB and SE-MB was greater than that provided by ER-RB and SE-RB (P < 0.05). ER-MB showed the lowest bond strength at 24 h (P < 0.05). At 1 year, SE-MB and SERB exhibited the highest bond strength values (P < 0.05). ER-MB demonstrated a higher incidence of adhesive failure at 24 h. At 1 year, SE-RB and SE-MB showed a higher incidence of mixed failure. Conclusion: The use of Scotchbond Universal (R) adhesive in the etch-and-rinse strategy applied with a MB negatively affects bond strength at 24 h, worsening after 1 year of control, regardless of the application protocol.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Role of Etching Mode on Bonding Longevity of a Universal Adhesive to Eroded Dentin
    Forgerini, Tamires Vercelino
    Ribeiro, Jessica Fogliato
    Rocha, Rachel de Oliveira
    Maxnuck Soares, Fabio Zovico
    Lenzi, Tathiane Larissa
    JOURNAL OF ADHESIVE DENTISTRY, 2017, 19 (01) : 69 - 75
  • [22] Effects of adhesive temperature on the early and 6-month dentin bonding
    Reis, Alessandra
    Klein-Junior, Celso Afonso
    Rodrigues Accorinte, Maria de Lourdes
    Miranda Grande, Rosa Helena
    dos Santos, Celso Bilynkievycz
    Loguercio, Alessandro D.
    JOURNAL OF DENTISTRY, 2009, 37 (10) : 791 - 798
  • [23] Adhesion strategy and curing mode of a universal adhesive influence the bonding of dual-cured core build-up resin composite to dentin
    Elsayed, Ahmed Eid
    Kamel, Mohamed Amr
    El-Askary, Farid Sabry
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2021, 35 (01) : 52 - 62
  • [24] High intensity focused ultrasound enhances bonding of universal adhesive to dentin in self-etch mode
    Fu, Cheryl
    Awad, Mohamed M.
    Bridgwood, Jackie
    Boon, Sarah
    Hashimi, Masooma
    Clode, Peta L.
    Fawzy, Amr S.
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2025, 138
  • [25] Influence of adhesive application method and thermocycling on the bonding performance of different adhesive systems to dentin
    Moharam, Lamiaa
    Afifi, Rasha
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2023, 15 (02): : 168 - 173
  • [26] Comparative Evaluation of the Sealing Ability of a BioCeramic Sealer (iRoot SP) with AH Plus Sealer with Root Canal Dentin Using Three Different Techniques of Sealer Application: A Combined Dye Extraction and Scanning Electron Microscope Study
    Bhor, Shreya
    Rao, Ajay Singh
    Shah, Unnati
    Mathur, Meetu
    Reda, Rodolfo
    Pagnoni, Francesco
    Testarelli, Luca
    Luke, Alexander Maniangat
    Pawar, Ajinkya M.
    JOURNAL OF COMPOSITES SCIENCE, 2023, 7 (03):
  • [27] Does Bonding Approach Influence the Bond Strength of Universal Adhesive to Dentin of Primary Teeth?
    Lenzi, Tathiane Larissa
    Maxnuck Soares, Fabio Zovico
    Rocha, Rachel de Oliveira
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2017, 41 (03) : 214 - 218
  • [28] Does the universal adhesive's film thickness affect dentin-bonding effectiveness?
    Tang, Chuliang
    Mercelis, Ben
    Yoshihara, Kumiko
    Peumans, Marleen
    Van Meerbeek, Bart
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (02)
  • [29] Effect of adhesive system and application strategy on reduction of dentin permeability
    Carvalho, Adriana Oliveira
    de Oliveira, Marcelo Tavares
    Nikaido, Toru
    Tagami, Junji
    Giannini, Marcelo
    BRAZILIAN ORAL RESEARCH, 2012, 26 (05) : 397 - 403
  • [30] Influence of Low-Level Laser Modification and Adhesive Application Mode on the Bonding Efficiency of Universal Adhesives to Er:YAG Laser-Ablated Dentin
    Elsahn, Nesrine A.
    El-Damanhoury, Hatem M.
    Elkassas, Dina W.
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2021, 12 : 1 - 9