Effects of the application protocol and bonding strategy of the universal adhesive on dentin previously impregnated with bioceramic sealer

被引:0
|
作者
Barros, Antonia Patricia Oliveira [1 ]
Costa, Joatan Lucas de Sousa Gomes
Monteiro, Jardel Camilo do Carmo [1 ,2 ]
Galvani, Lucas David [3 ]
de Andrade, Marcelo Ferrarezi [1 ]
Saad, Jose Roberto Cury [1 ]
Kuga, Milton Carlos [1 ]
机构
[1] Sao Paulo State Univ, Araraquara Dent Sch, Dept Operat Dent, Araraquara, SP, Brazil
[2] Univ Fed Minas Gerais, Dept Restorat Dent, Belo Horizonte, MG, Brazil
[3] Sao Paulo State Univ, Araraquara Dent Sch, Dept Dent Mat & Prosthet, Araraquara, SP, Brazil
关键词
Bond strength; Failure modes; Protocols; Bioceramic Sealer; Root canal filling material; STRENGTH; SYSTEMS; IMPROVE;
D O I
10.1016/j.ijadhadh.2024.103765
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Purpose: To evaluate the effects of the application of universal adhesive with manual brush (MB) or rotary brush (RB), in the etch-and-rinse (ER) or self-etching (SE) strategy, on the bond strength, adhesive layer thickness, and adhesive failure pattern to dentin impregnated with bioceramic sealer, at 24 h and 1 year. Materials and methods: Eighty-eight bovine incisor crowns were impregnated with bioceramic sealer was kept for 15 min and cleaned with cotton soaked in distilled water. They were then divided into four groups (n = 22): ERMB, ER-RB, SE-MB, SE-RB. Subsequently, the specimens were restored with Filtek Z-250 resin. The adhesive layer thickness was individually analyzed using laser confocal microscope. Bond strength was assessed through microtensile testing, and the failure pattern was examined using a stereomicroscope. Data were analyzed by oneway ANOVA/Tukey 's tests ( alpha = 0.05). Results: The adhesive layer thickness provided by ER-MB and SE-MB was greater than that provided by ER-RB and SE-RB (P < 0.05). ER-MB showed the lowest bond strength at 24 h (P < 0.05). At 1 year, SE-MB and SERB exhibited the highest bond strength values (P < 0.05). ER-MB demonstrated a higher incidence of adhesive failure at 24 h. At 1 year, SE-RB and SE-MB showed a higher incidence of mixed failure. Conclusion: The use of Scotchbond Universal (R) adhesive in the etch-and-rinse strategy applied with a MB negatively affects bond strength at 24 h, worsening after 1 year of control, regardless of the application protocol.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Influence of bioceramic sealer residues on the adhesion interface with a universal adhesive in the etch-and-rinse strategy, based on the application protocol and evaluation time
    Costa, Joatan Lucas de Sousa Gomes
    Oliveira, Antonia Patricia
    Gelio, Mariana Bena
    Galvani, Lucas David
    Vaz, Luis Geraldo
    Kuga, Milton Carlos
    DENTAL MATERIALS JOURNAL, 2024, 43 (04) : 565 - 572
  • [2] Influence of residues from bioceramic sealer on the bond interface with universal adhesive in different application modes
    Costa, Joatan Lucas de Sousa Gomes
    Barros, Antonia Patricia Oliveira
    Junior, Adirson Jorge
    Gelio, Mariana Bena
    Dantas, Andrea Abi Rached
    Kuga, Milton Carlos
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2024, 132 (04)
  • [3] The Influence of Application Protocol of Simplified and Universal Adhesives on the Dentin Bonding Performance
    Zecin-Deren, Anna
    Lukomska-Szymanska, Monika
    Szczesio-Wlodarczyk, Agata
    Piwonski, Ireneusz
    Sokolowski, Jerzy
    Lapinska, Barbara
    APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [4] Effect of adhesive strategy on resin cement bonding to dentin
    Mazzitelli, Claudia
    Maravic, Tatjana
    Josic, Uros
    Mancuso, Edoardo
    Generali, Luigi
    Checchi, Vittorio
    Breschi, Lorenzo
    Mazzoni, Annalisa
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (03) : 501 - 507
  • [5] Bonding effects of cleaning protocols and time-point of acid etching on dentin impregnated with endodontic sealer
    Manzoli, Tatiane Miranda
    Zaniboni, Joissi Ferrari
    Besegato, Joao Felipe
    Guiotti, Flavia Angelica
    Rached Dantas, Andrea Abi
    Kuga, Milton Carlos
    RESTORATIVE DENTISTRY AND ENDODONTICS, 2022, 47 (02)
  • [6] Bonding of chitosan and nanochitosan modified universal adhesive to dentin
    El-Din, Yasmin Ezz
    El-Banna, Ahmed
    Hussein, Tarek Salah
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2023, 125
  • [7] In vitro performance of an autocured universal adhesive system in bonding to dentin
    Kibe, Kota
    Hatayama, Takashi
    Shimada, Yasushi
    BMC ORAL HEALTH, 2023, 23 (01)
  • [8] Impact of cleansing protocols to remove endodontic sealer residues on the adhesive interface: Bonding with universal adhesive systems
    Zaniboni, Joissi Ferrari
    de Souza, Vitor
    Gustavo Escalante-Otarola, Wilfredo
    Porto, Thiago Soares
    Fernandez Godoy, Eduardo
    Kuga, Milton Carlos
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (07) : 1077 - 1084
  • [9] Application of β-Tricalcium Phosphate in Adhesive Dentin Bonding
    AlRefeai, Mohammad H.
    AlHamdan, Eman M.
    Al-Saleh, Samar
    Alqahtani, Abdulaziz S.
    Al-Rifaiy, Mohammad Q.
    Alshiddi, Ibraheem F.
    Farooq, Imran
    Vohra, Fahim
    Abduljabbar, Tariq
    POLYMERS, 2021, 13 (17)
  • [10] Evaluation of the bonding effectiveness of a universal adhesive to the plasma-activated dentin surface
    Temel, Ugur Burak
    Hepdeniz, Ozge Kam
    Gulec, Ali
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2023, 131 (01)