Electrochemical Sensing of Bisphenol A Using Metal Organic Framework/Quantum Dot Composite Modified Gold Electrode

被引:0
|
作者
Oloyede, Solomon O. [1 ]
Ajibade, Peter A. [1 ]
机构
[1] Univ KwaZulu Natal, Sch Chem & Phys, Private Bag X01, ZA-3209 Pietermaritzburg, South Africa
来源
CHEMELECTROCHEM | 2024年 / 11卷 / 19期
基金
新加坡国家研究基金会;
关键词
Bisphenol A; Composites; Electrochemistry; Metal organic framework; Quantum dots; TOLFENAMIC ACID STRUCTURE; CRYSTAL-STRUCTURE; QUANTUM DOTS; SENSITIVE DETECTION; SENSOR; NANOPARTICLES; COMPLEXES; POLYMER; COPPER; WATER;
D O I
10.1002/celc.202400242
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Electrochemical sensors based on self-assembled monolayer (SAM) were synthesized using metal-organic frameworks (MOFs), quantum dots (QDs) and their composite (QDs@MOFs) to modify gold electrode (AuE) that was used as electrochemical sensors for bisphenol A detection. The molecular layer was assembled on the surface of the gold electrode by adsorption and provide a highly flexible method to tailor the interfaces between analyte and the electrode. Single crystal X-ray of the MOF revealed a six-coordinate copper(II) ion that bidentately coordinate two molecules of p-anisic acid and two molecules of 1H-benzimidazole to form a distorted octahedral geometry around the copper(II) ion. Electrochemical studies revealed that under optimal conditions, the modified gold electrode sensors show excellent sensing of bisphenol A, however, QDs@MOFs modified electrode is the best sensor with the highest oxidation peak current of 8.43E-05 mu A and the lowest charge transfer resistance of 19.4 Omega within a wide concentration range of 0.1-1 mu M and a limit of detection (LOD) of 0.252 mu M. This could be attributed to the electrocatalytic activity of the composite (QDs@MOFs) modified sensor, and the synergistic effect of the MOFs and QDs in the composite. The LOD is comparable to other electrochemical methods of sensing BPA which indicates that QDs@MOFs modified gold electrode could be develop as sensor for BPA. Fabrication of electrochemical sensor using copper(II) metal organic framework and quantum dots composites to modify gold electrode for the detection of bisphenol A. The composite modified gold electrode acts as sensors with excellent sensitivity for bisphenol A determination over a wide concentration range with good detection limit. image
引用
收藏
页数:14
相关论文
共 50 条
  • [21] A novel pencil graphite electrode modified with an iron-based conductive metal-organic framework exhibited good ability in simultaneous sensing bisphenol A and bisphenol S
    Chen, Jin-Yang
    Weng, Ying-Xin
    Han, Yong -He
    Ye, Rui-Hong
    Huang, Di -Hui
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2024, 272
  • [22] An Electrochemical Sensor Based on Gold Nanodendrite/Surfactant Modified Electrode for Bisphenol A Detection
    Nguyen Thi Lien
    Le Quoc Hung
    Nguyen Tien Hoang
    Vu Thi Thu
    Dau Thi Ngoc Nga
    Pham Thi Hai Yen
    Pham Hong Phong
    Vu Thi Thu Ha
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2020, 2020
  • [23] A novel electrochemical sensor of tryptophan based on silver nanoparticles/metal-organic framework composite modified glassy carbon electrode
    Peng, Zhewei
    Jiang, Zhongwei
    Huang, Xin
    Li, Yuanfang
    RSC ADVANCES, 2016, 6 (17) : 13742 - 13748
  • [24] A novel electrochemical sensor of bisphenol A based on stacked graphene nanofibers/gold nanoparticles composite modified glassy carbon electrode
    Niu, Xiuli
    Yang, Wu
    Wang, Guoying
    Ren, Jie
    Guo, Hao
    Gao, Jinzhang
    ELECTROCHIMICA ACTA, 2013, 98 : 167 - 175
  • [25] Electrochemical detection of silver ions by using sulfur quantum dots modified gold electrode
    Fu, Li
    Wang, Aiwu
    Xie, Kefeng
    Zhu, Jiangwei
    Chen, Fei
    Wang, Henggang
    Zhang, Huaiwei
    Su, Weitao
    Wang, Zhenguang
    Zhou, Cangtao
    Ruan, Shuangchen
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 304
  • [26] Electrochemical behavior of dopamine in presence of Ascorbic Acid by using an electrochemical modified gold electrode and an electrochemical and chemical modified gold electrode with a thiol
    Menolasina, Sabino
    Contreras, Ricardo R.
    Aguilar, Anfrelis
    Contreras, Olga
    Rodriguez, Alexis
    REVISTA TECNICA DE LA FACULTAD DE INGENIERIA UNIVERSIDAD DEL ZULIA, 2007, 30 (02): : 151 - 156
  • [27] Development of electrochemical 3-MCPD sensor based on molecularly imprinted polymer coating on metal organic framework modified gold electrode
    Ozyurt, Vasfiye Hazal
    Can, Goksu
    Anik, Ulku
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2025, 138
  • [28] Cotinuous precision separation of gold using a metal–organic framework/polymer composite
    Mitchell, Emily
    Hernandez, Dana
    Deatherage, Ashlin
    Coull, Martin
    Altoé, M. Virginia
    Klivansky, Liana
    Witman, Matthew
    Sun, Daniel T
    Nanotechnology, 2024, 35 (19)
  • [29] Non-Enzymatic Electrochemical Sensing of Bisphenol A in Drinking Water and Milk Using Bimetallic Nickel-Copper Metal–Organic Framework
    Baban Dey
    MdWasi Ahmad
    Refat AlShannaq
    Jehan YAlHumaidi
    SKSafdar Hossain
    Chandra NPatra
    Raed HAlthomali
    Mohammed MRahman
    Arup Choudhury
    Journal of Analysis and Testing, 2024, 8 (04) : 451 - 465
  • [30] Copper porphyrin metal-organic framework modified carbon paper for electrochemical sensing of glyphosate
    Jiang, Rui
    Pang, Yue-Hong
    Yang, Qiu-Yu
    Wan, Chao-Qun
    Shen, Xiao-Fang
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 358