Analysis of Surgical Smoke Generated by Electrocautery in a Simulated Neurosurgical Operating Room Using a Postmortem Porcine Model for Laminectomy and Craniotomy Exposures: A Preliminary Study

被引:0
作者
Levy, Bennett R. [1 ]
Monteiro, Andre [2 ,3 ]
Jaikumar, Vinay [2 ,3 ]
Donnelly, Brianna M. [2 ,3 ]
Smolar, David E. [2 ]
Lim, Jaims [2 ]
Mullin, Jeffrey P. [2 ,4 ]
Levy, Elad I. [2 ,3 ,4 ,5 ,6 ]
机构
[1] George Washington Univ, Sch Med & Hlth Sci, Washington, DC USA
[2] SUNY Buffalo, Jacobs Sch Med & Biomed Sci, Dept Neurosurg, Buffalo, NY USA
[3] Kaleida Hlth, Gates Vasc Inst, Dept Neurosurg, Buffalo, NY USA
[4] Jacobs Inst, Buffalo, NY USA
[5] SUNY Buffalo, Jacobs Sch Med & Biomed Sci, Dept Radiol, Buffalo, NY USA
[6] SUNY Buffalo, Canon Stroke & Vasc Res Ctr, Jacobs Sch Med & Biomed Sci, Buffalo, NY USA
来源
NEUROSURGERY PRACTICE | 2023年 / 4卷 / 04期
关键词
Craniotomy; Electrocautery; Laminectomy; Neurosurgery; Occupational hazard; Porcine model; Surgical smoke;
D O I
10.1227/neuprac.0000000000000066
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND OBJECTIVES: Electrocautery is a widely used tool to coagulate and separate tissue during neurosurgical procedures. Surgical smoke generated by electrocautery has harmful properties if inhaled over long-term. To our knowledge, no efforts have been made within the neurosurgery field to investigate the air quality of operating rooms (ORs) where neurosurgical procedures are being performed. We analyzed the presence and quantitation of volatile organic compounds and respirable dust in surgical smoke generated by electrocautery use during a neurosurgical OR simulation for laminectomies and craniotomies and evaluated whether surgical masks can adequately prevent inhalation of such substances. METHODS: Two laminectomy exposures and two bicoronal exposures were performed in two freshly euthanized pigs using electrocautery in a simulated neurosurgical OR. In each of the four neurosurgical procedure models, air sampling media and pumps were connected to a 3D-printed human face model. In two of these models, the face was covered with a standard surgical mask; in the other two models, no masks were placed. The models were positioned at a distance of 40 cm from the surgical field. Air samples were analyzed by an independent laboratory. Analyses of total amounts of respirable dust and 31 organic volatile compounds were conducted. The mean total amounts of the samples obtained from the masked and nonmasked models were compared. RESULTS: In the two masked and two nonmasked models, all 31 organic volatile compounds were below the levels of quantitation. The total amounts of respirable dust were higher in the two nonmasked models than in the two masked models. CONCLUSION: The total amount of organic volatile compounds seems to be low at the distance measured regardless of mask use; however, further studies are needed to determine whether even small amounts can be harmful over time. Standard surgical masks reduced the amounts of inhalable respirable dust.
引用
收藏
页数:5
相关论文
共 9 条
  • [1] Barber L, 2022, NEW ZEAL MED J, V135, P18, DOI [10.5487/MED.8741, 10.26635/6965.5632]
  • [2] Distribution of ultrafine aerosols and volatile organic compounds from surgical smoke during electrocauterization
    Chen, Chi-Tsung
    Huang, Shiang-Fu
    Li, Cheng-Jung
    Huang, Jou-Mien
    Chang, Kai-Ping
    Wan, Gwo-Hwa
    [J]. AIR QUALITY ATMOSPHERE AND HEALTH, 2022, 15 (11) : 2009 - 2020
  • [3] Smoke in the operating theater: An unregarded source of danger
    Hollmann, R
    Hort, CE
    Kammer, E
    Naegele, M
    Sigrist, MW
    Meuli-Simmen, C
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2004, 114 (02) : 458 - 463
  • [4] Kocher GJ, 2019, EUR J CARDIO-THORAC, V55, P626, DOI 10.1093/ejcts/ezy356
  • [5] Investigating surgical smoke in otolaryngology operating rooms
    Li, Chun-, I
    Chou, Ying-Hsiang
    Pai, Jar-Yuan
    Chen, Chih-Hsuan
    Chiang, Min-Chi
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [6] Merajikhah A, 2022, IRAN J PUBLIC HEALTH, V51, P27, DOI 10.18502/ijph.v51i1.8289
  • [7] TOMITA Y, 1981, MUTAT RES, V89, P145
  • [8] Composition of the electrocautery smoke: integrative literature review
    Tramontini, Cibele Cristina
    Galvao, Cristina Maria
    Claudio, Caroline Vieira
    Ribeiro, Renata Perfeito
    Martins, Julia Trevisan
    [J]. REVISTA DA ESCOLA DE ENFERMAGEM DA USP, 2016, 50 (01) : 144 - 153
  • [9] Electrocautery, Diathermy, and Surgical Energy Devices Are Surgical Teams at Risk During the COVID-19 Pandemic?
    Zakka, Kimberley
    Erridge, Simon
    Chidambaram, Swathikan
    Beatty, Jasmine Winter
    Kynoch, Michael
    Kinross, James
    Purkayastha, Sanjay
    [J]. ANNALS OF SURGERY, 2020, 272 (03) : E257 - E262