Analysis oriented model for hybrid filament wound FRP-concrete-steel double skin tubular columns (DSTC) under axial compression

被引:0
作者
Bhat, Pronnoy [1 ]
Jamatia, Rimen [1 ]
机构
[1] Indian Inst Technol Jammu, Dept Civil Engn, Jammu 181221, Jammu & Kashmir, India
关键词
Double skin tubular columns; Analysis-oriented model; FRP-confined concrete; Off-axis fiber; Multi-axial compression; STRESS-STRAIN MODEL; FIBER ORIENTATION; NONLINEAR BEHAVIOR; CONFINED CONCRETE; COMPOSITE; STRENGTH; CYLINDERS; THICKNESS; DUCTILITY; ANGLE;
D O I
10.1016/j.jcsr.2024.109008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
There exists no analytical model in the literature capable of predicting the stress-strain behavior of hybrid filament wound fiber reinforced polymer (FRP)-concrete-steel double skin tubular columns (DSTC) under axial compression. To address this, an analytical model is first developed to incorporate bi-directional fibers and predict the non-linear hoop stress-hoop strain response in filament wound FRP laminated cylindrical tube under internal pressure. This model is then used to predict the confinement pressure exerted by the FRP tube on the sandwiched concrete in DSTC when subjected to uniaxial compression. Next, an analysis-oriented model is used to predict the complete stress-strain response of DSTC confined by bi-directional FRP tube. The model's predictions are compared with the test results collected from literature, and based on performance parameters, it is concluded that the proposed model significantly reduces the error in predicting the global axial stress-strain behavior of DSTC with bidirectional FRPs. Parametric studies are then performed to understand the influence of geometrical parameters and material properties on the axial behavior of DSTC. It was found that the variation of effective confinement pressure across the concrete section is the key factor influencing the global axial stressstrain behavior. Finally based on these parametric studies, a critical confining stiffness necessary to supress the softening response in DSTC was proposed, which is dependent on the void ratio of these columns.
引用
收藏
页数:20
相关论文
共 58 条
[1]   Effect of fiber orientation and ply mix on fiber reinforced polymer-confined concrete [J].
Au, C ;
Buyukozturk, O .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (05) :397-407
[2]  
Bakis C.E., 2002, Reported by ACI Committee 440
[3]   Effects of Small Deviations in Fiber Orientation on Compressive Characteristics of Plain Concrete Cylinders Confined with FRP Laminates [J].
Banaeipour, Ali ;
Tavakkolizadeh, Mohammadreza ;
Akbar, Muhammad ;
Hussain, Zahoor ;
Ostrowski, Krzysztof Adam ;
Bahadori, Alireza ;
Spyrka, Mariusz .
MATERIALS, 2023, 16 (01)
[4]   Compressive stress-strain model for concrete-filled filament-wound FRP tubes with arbitrary fiber orientation: An analytical approach [J].
Bhat, Pronnoy ;
Jamatia, Rimen .
CONSTRUCTION AND BUILDING MATERIALS, 2024, 436
[5]   Analytical stress-strain model of hybrid FRP-concrete-steel double skin tubular columns under axial compression [J].
Bhat, Pronnoy ;
Jamatia, Rimen .
ENGINEERING STRUCTURES, 2023, 286
[6]   An analytical model for stress-strain behavior of confined concrete [J].
Binici, B .
ENGINEERING STRUCTURES, 2005, 27 (07) :1040-1051
[7]  
Boresi A.P., 1985, ADV MECH MAT, V6, DOI DOI 10.1063/1.3060940
[8]   Influence of filament winding parameters on composite vessel quality and strength [J].
Cohen, D .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 1997, 28 (12) :1035-1047
[9]   Comparative study of models on confinement of concrete cylinders with fiber-reinforced polymer composites [J].
De Lorenzis, L ;
Tepfers, R .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2003, 7 (03) :219-237
[10]  
Fam AZ, 2001, ACI STRUCT J, V98, P451