Cyclic loading experiments on seismic performance of precast concrete superposed shear walls with CFST end columns

被引:3
|
作者
Wu, Bian [1 ]
Zhang, Feng-Liang [1 ,2 ]
Zhang, Min [3 ]
Li, Yong [4 ]
机构
[1] Harbin Inst Technol, Sch Civil & Environm Engn, Shenzhen 518055, Peoples R China
[2] Harbin Inst Technol, Guangdong Prov Key Lab Intelligent & Resilient Str, Shenzhen 518055, Peoples R China
[3] Sichuan Coll Architectural Technol, Dept Civil Engn, Deyang 618000, Peoples R China
[4] Shenzhen Univ, Coll Civil & Transportat Engn, Shenzhen 518060, Peoples R China
来源
关键词
Seismic performance; Experimental investigation; Concrete superposed shear wall; Precast concrete; CFST end column; Composite shear wall; OF-THE-ART; AXIAL LOAD; BEHAVIOR; DESIGN; MODEL; STRENGTH; PANELS;
D O I
10.1016/j.jobe.2024.110527
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The seismic performance of precast concrete shear walls is a major concern when considering their application in earthquake-prone regions. To improve the seismic performance and constructability of conventional precast concrete superposed shear walls, an innovative design, termed Precast Concrete Superposed Shear Walls with CFST End Columns (PCSSWEC), has been proposed. Given the limited research on the seismic performance of PCSSWECs, cyclic loading experiments were conducted on three full-scale PCSSWEC specimens and one monolithic RC shear wall specimen. The design axial compression ratio (ACR) and the thickness of the steel tube were employed as research variables. Experimental observations and results gave a comprehensive view of the hysteretic behavior of PCSSWECs, reflecting a favorable seismic performance (in terms of failure modes, global and local damage, force-displacement responses, load-bearing capacity, stiffness and strength degradation, deformability, ductility, and energy dissipation capacity). The experiment also revealed significant differences between PCSSWECs and monolithic RC shear walls in concrete crack development and deformation characteristics, confirming that the CFST columns and the wall panel could work together until the failure phase. Moderately increasing the ACR (0.3-0.5) was beneficial for PCSSWECs. However, increasing the steel tube thickness (3.5 mm-5.0 mm) could lead to unfavorable degradation in strength and stiffness and weaken ductility. In addition, a simplified method was proposed to evaluate the flexural strength of PCSSWECs.
引用
收藏
页数:26
相关论文
共 50 条
  • [31] Seismic Behavior of Rammed Earth Walls with Precast Concrete Tie Columns
    Yang, Xinlei
    Wang, Hailiang
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2018, 2018
  • [32] Seismic Performance of Precast Unbonded Prestressed Concrete Columns
    Yamashita, Ryo
    Sanders, David H.
    ACI STRUCTURAL JOURNAL, 2009, 106 (06) : 821 - 830
  • [33] Postfire seismic performance of reinforced precast concrete columns
    Demir, Ugur
    Green, Mark F.
    Ilki, Alper
    PCI JOURNAL, 2020, 65 (06): : 62 - 80
  • [34] Seismic performance of precast reinforced and prestressed concrete walls
    Holden, T
    Restrepo, J
    Mander, JB
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (03): : 286 - 296
  • [35] The seismic performance of precast short-leg shear wall under cyclic loading
    Du, Xiuli
    Wu, Min
    Liu, Hongtao
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (03) : 570 - 582
  • [36] Seismic performance of precast posttensioned concrete frame under low reversed cyclic loading
    Hu, Xiang
    Xue, Weichen
    Liao, Xiandong
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2021, 30 (08):
  • [37] LOW-CYCLIC REVERSED LOADING TEST FOR DOUBLE-WALL PRECAST CONCRETE SHEAR WALLS
    Xiao, Quandong
    Guo, Zhengxing
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 380 - 388
  • [38] Experimental study on precast concrete sandwich insulation shear walls under low reversed cyclic loading
    Xue, Weichen
    Yang, Jialin
    Dong, Niancai
    Li, Kang
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2013, 43 (05): : 1104 - 1110
  • [39] Low-cyclic reversed loading test for double-wall precast concrete shear walls
    Xiao, Quandong
    Guo, Zhengxing
    Guo, Zhengxing, 1600, Southeast University (44): : 826 - 831
  • [40] Experimental study on seismic behavior of steel plate reinforced concrete composite shear walls with square CFST concealed columns
    Nie, Jianguo
    Hu, Hongsong
    Li, Shengyong
    Liu, Fujun
    Fan, Jiansheng
    Tao, Muxuan
    Shao, Dacheng
    Yu, Deming
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2013, 34 (01): : 52 - 60