Potential role of the light-adjustable lens in flanged intrascleral haptic fixation

被引:2
作者
LoBue, Stephen A. [1 ]
Saba, Nicholas [2 ]
Catapano, Thomas M. [3 ]
Martin, Curtis R. [1 ]
Shelby, Christopher L. [1 ]
Coleman III, Wyche T. [1 ]
机构
[1] Willis Knighton Med Ctr, Dept Ophthalmol, Suite 116, Shreveport, LA 71118 USA
[2] SUNY Downstate Med Ctr, Dept Ophthalmol, Brooklyn, NY USA
[3] St Georges Univ, Sch Med, True Blue, Grenada
关键词
CHAMBER INTRAOCULAR-LENS; PARS-PLANA VITRECTOMY; SCLERAL FIXATION; IMPLANTATION; ACCURACY; OUTCOMES; APHAKIA;
D O I
10.1097/j.jcrs.0000000000001455
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To compare maximum tensile strength between commonly used 3-piece intraocular lens (IOL) for flanged intrascleral haptic fixation (FISHF). Setting:Willis-Knight Eye Institute, Shreveport, Louisiana. Design:Laboratory investigation. Methods:Haptic tensile strength was compared with MA60AC, CT Lucia 602, AR40E, and the light-adjustable lens (LAL). Haptic strength with a 24-diopter (D) IOL was compared across all lenses, as well as across a range of 10 to 30 D with the MA60AC. A custom device was created to hold the IOL in correct haptic orientation. The maximum tension (mean +/- SD) was recorded in Newtons (N) when the haptic lost tension or broke. Results:CT Lucia was the strongest at 1.53 +/- 0.11 N vs 1.00 +/- 0.15 (MA60AC), 0.87 +/- 0.19 (AR40E), and 0.83 +/- 0.14 N (LAL) (P < .001). The LAL and AR40E were similar to a 9-0 polypropylene suture while being significantly stronger than 10-0 polypropylene suture (P < .001). No difference in haptic tension for the MA60AC from 10 to 30 D (P > .05). High magnification revealed the highest haptic fractures for MA60AC at 40% compared with LAL, AR40E, and CT Lucia at 0%. CT Lucia and AR40E had 100% of haptics disinserted from the IOL without any damage compared with 60% LAL and 60% MA60AC. CT Lucia, AR40E, and LAL have a flatter haptic angulation at 5 degrees. Conclusions:Haptic strength, durability, and angulation of the LAL may support the possibility of FISHF in the hands of experienced surgeons. However, further testing is strongly recommended to verify whether physiologic conditions or light treatments may compromise long-term haptic stability.
引用
收藏
页码:754 / 759
页数:6
相关论文
共 28 条
  • [1] Adjustable 6-0 polypropylene flanged technique for scleral fixation, part 1: primary fixation IOLs in aphakia, capsular stabilizing devices, and aniridia implants
    Assia, Ehud, I
    Wong, John Xh
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (10) : 1387 - 1391
  • [2] Adjustable 6-0 polypropylene flanged technique for scleral fixation, part 2: repositioning of subluxated IOLs
    Assia, Ehud, I
    Wong, John X. H.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (10) : 1392 - 1396
  • [3] Long-term outcome of scleral-sutured posterior chamber intraocular lens: a case series
    Bausili Portabella, Maria Montserrat
    Nadal, Jeroni
    Alvarez de Toledo, Juan
    Fideliz de la Paz, Maria
    Barraquer, Rafael Ignacio
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (05) : 712 - 717
  • [4] Brandser R, 1997, ACTA OPHTHALMOL SCAN, V75, P162
  • [5] Refractive Results after Implantation of a Light-Adjustable Intraocular Lens in Postrefractive Surgery Cataract Patients
    Brierley, Lawrence
    [J]. OPHTHALMOLOGY, 2013, 120 (10) : 1968 - 1972
  • [6] Long-term outcomes for pediatric patients having transscleral fixation of the capsular bag with intraocular lens for ectopia lentis
    Byrd, Julia M.
    Young, Marielle P.
    Liu, Wei
    Zhang, Yue
    Tate, David B.
    Crandall, Alan S.
    Owen, Leah A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (05) : 603 - 609
  • [7] Scleral fixation of a 4-eyelet foldable intraocular lens in patients with aphakia using a 4-flanged technique
    Canabrava, Sergio
    Andrade Jr, Newton
    Henriques, Pedro Rezende
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (02) : 265 - 269
  • [8] Use of the light-adjustable lens to correct astigmatism after cataract surgery
    Chayet, Arturo
    Sandstedt, Chris
    Chang, Shiao
    Rhee, Paul
    Tsuchiyama, Barbara
    Grubbs, Robert
    Schwartz, Dan
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (06) : 690 - 692
  • [9] Adjustable intraocular lens power technology
    Ford, Joshua
    Werner, Liliana
    Mamalis, Nick
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (07) : 1205 - 1223
  • [10] Results in comparison between 30 gauge ultrathin wall and 27 gauge needle in sutureless intraocular lens flanged technique in diabetic patients: 24-month follow-up study
    Iglicki, Matias
    Zur, Dinah
    Negri, Hermino Pablo
    Esteves, Joaquin
    Arias, Romina
    Holsman, Emanuel
    Loewenstein, Anat
    Busch, Catharina
    [J]. ACTA DIABETOLOGICA, 2020, 57 (10) : 1151 - 1157