Smart bandages with integrated sensors for real-time monitoring of wound inflammation and infection

被引:1
|
作者
Azzahrani, Ahmad S. [1 ]
Alsheikhy, Ahmed A. [1 ]
Kadhim, Ahmed C. [2 ]
Resen, Dheyaa A. [3 ]
机构
[1] Northern Borders Univ, Dept Elect Engn, Ar Ar, Saudi Arabia
[2] Univ Technol Iraq, Dept Commun Engn, Baghdad, Iraq
[3] Middle Tech Univ, Inst Technol, Baghdad, Iraq
来源
关键词
All-optical interference; Gold-coated FBGs; Healthcare management; Wound inflammation; Infection detection;
D O I
10.1007/s12596-024-02235-9
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Current diagnostic and treatment of chronic wound modalities cannot provide accurate information because they cannot account for dynamic changes in the wound environment or predict the healing outcome. Therefore, there remains a pressing need for more efficient methods like intelligent bandages that can indicate the current state of the wound and help determine whether the wound is on track to heal. A noninvasive wearable fiber optic smart bandage with fiber Bragg grating fiber optic sensor is proposed to realize smart bandages that support the diagnosis and treatment of chronic wound modalities. The device has all-optical interference phenomena to help monitor the status and history of the wound during and after therapy. The suggested fiber optic sensor consists of a thin layer of gold coated onto the fiber Bragg gratings. The cladding of the FBGs was etched to a thickness of 20 mu m to optimize the interaction with the chronic wound environment. The sensing FBG was coated with a 50nm thick layer of gold to enhance the sensing capabilities. The system is configured to monitor changes in the reflected frequencies of the sensing FBG in response to temperature variations in the structure of the FBG in the wound bed. The reflected frequencies of both the local and sensing FBGs are combined within the same input line of the FBG. The response variations within the 37.3-37.9 degrees C range is approximately 34.95 pm/degrees C. The sensitivity of the generated beat frequency is 4.37GHz, and the variations in the beat frequency as the temperature changes provide valuable insights into the sensor's response. smart bandages for chronic wounds can be feasible with high-precision, noninvasive fiber optic sensors.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] An Integrated Smart Sensor Dressing for Real-Time Wound Microenvironment Monitoring and Promoting Angiogenesis and Wound Healing
    Zhang, Yuheng
    Li, Tian
    Zhao, Congying
    Li, Jinqing
    Huang, Rong
    Zhang, Qianru
    Li, Yongqian
    Li, Xueyong
    FRONTIERS IN CELL AND DEVELOPMENTAL BIOLOGY, 2021, 9
  • [2] Smart sensors for real-time monitoring of patients on dialysis
    Fokko P. Wieringa
    Jeroen P. Kooman
    Nature Reviews Nephrology, 2020, 16 : 554 - 555
  • [3] Smart sensors for real-time monitoring of patients on dialysis
    Wieringa, Fokko P.
    Kooman, Jeroen P.
    NATURE REVIEWS NEPHROLOGY, 2020, 16 (10) : 554 - 555
  • [4] Smart bandages diagnose wound infection
    Whelan, J
    DRUG DISCOVERY TODAY, 2002, 7 (01) : 9 - 10
  • [5] Design of Smart Sensors for Real-Time Water Quality Monitoring
    Cloete, Niel Andre
    Malekian, Reza
    Nair, Lakshmi
    IEEE ACCESS, 2016, 4 : 3975 - 3990
  • [6] Real-time wound management through integrated pH sensors: a review
    Khan, Munezza Ata
    Ansari, Umar
    Ali, Murtaza Najabat
    SENSOR REVIEW, 2015, 35 (02) : 183 - 189
  • [7] Smart Bandaid Integrated with Fully Textile OECT for Uric Acid Real-Time Monitoring in Wound Exudate
    Arcangeli, Danilo
    Gualandi, Isacco
    Mariani, Federica
    Tessarolo, Marta
    Ceccardi, Francesca
    Decataldo, Francesco
    Melandri, Federico
    Tonelli, Domenica
    Fraboni, Beatrice
    Scavetta, Erika
    ACS SENSORS, 2023, 8 (04) : 1593 - 1608
  • [8] Flexible sensors for real-time monitoring of moisture levels in wound dressings
    Messaoud, Mouna
    Marsiquet, Cyril
    Revol-Cavalier, Frederic
    Rat, Venceslass
    Marchand, Gilles
    JOURNAL OF WOUND CARE, 2018, 27 (06) : 385 - 391
  • [9] Real-time process monitoring of micromoulding using integrated ultrasonic sensors
    Ono, Y.
    Whiteside, B. R.
    Brown, E. C.
    Kobayashi, M.
    Cheng, C. -C.
    Jen, C. -K.
    Coates, P. D.
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2007, 29 (05) : 383 - 401
  • [10] Smart wound dressing for advanced wound management: Real-time monitoring and on-demand treatment
    Pang, Qian
    Yang, Fang
    Jiang, Zilian
    Wu, Kaihao
    Hou, Ruixia
    Zhu, Yabin
    MATERIALS & DESIGN, 2023, 229