Evaluation of imaging dose for the cone beam computed tomography system of the ring-shaped radiotherapy unit using the different International Electrotechnical Commission approaches

被引:1
作者
Wang, Qingxin [1 ,2 ,3 ]
Li, Qifeng [1 ]
Wang, Zhongqiu [2 ]
Qu, Chengbin [2 ]
Wang, Yufei [2 ]
Zhang, Wenwen [2 ]
Li, Chunyin [2 ]
Zhao, Zhonglu [2 ]
Wang, Wei [2 ]
Sa, Yu [4 ]
机构
[1] Tianjin Univ, Sch Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Tianjin Med Univ Canc Inst & Hosp, Key Lab Canc Prevent & Therapy, Natl Clin Res Ctr Canc, Dept Radiat Oncol,Tianjins Clin Res Ctr Canc, Tianjin 300060, Peoples R China
[3] Hetian Dist Peoples Hosp, Dept Med Oncol, Hetian 848000, Xinjiang, Peoples R China
[4] Tianjin Univ, Med Sch, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Cone beam CT; Radiotherapy; Imaging dose; Computed tomography dose index; Halcyon; DNA-DAMAGE; RADIATION; CT; ACCUMULATION; DOSIMETRY; CBCT;
D O I
10.1016/j.radphyschem.2024.112165
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Purpose: Daily imaging is mandatory for the Halcyon and Ethos, which are the new ring-shaped radiotherapy units. This study quantified the imaging dose of the cone beam computed tomography (CBCT) system of the new ring-shaped radiotherapy units using the latest International Electrotechnical Commission (IEC) measurement approach. Furthermore, we investigated the influence of collimation width on the imaging dose and compared the imaging dose values obtained using three IEC measurement approaches. Methods: The IEC has proposed three approaches for measuring CTDI100: traditional, transition, and the latest measurement approach. In addition to the dose measured on the CTDI phantom, the latest IEC approach uses correction factors measured in free air for CTDI100 measurement. The imaging dose was measured for all scanning protocols using the latest IEC approach. To investigate the influence of the collimation width on the imaging dose, the associated dose metric values were evaluated and compared using different IEC approaches to increase the collimation width (2-28 cm). Furthermore, the imaging system output stability was evaluated by repeated measurements. Results: In the repeated measurements, the standard deviation of CTDIw value for the pelvis and head protocol was 0.05 mGy and 0.01 mGy, respectively. And the coefficient of variation was 0.21% and 0.23%, respectively. The measured CTDIw values of the clinical protocols were higher than the vendor-provided value, except for the pelvis protocol. The value of CTDIw changes little with increasing collimation width using the latest IEC approach. The traditional and transition approaches either underestimated or overestimated the value of CTDIw, as measured by the latest IEC approach, with increasing collimation width. Conclusions: The new ring-shaped radiotherapy units imaging system has good output stability. The CTDIw values measured for clinical scanning protocols generally exceeded the vendor-provided values. Compared with the latest IEC CTDI100 measurement approach, the traditional and transition measurement approaches were more influenced by beam width. For wide CBCT scans, rationalizing the choice of imaging dose measurement approach is important.
引用
收藏
页数:8
相关论文
共 50 条
[31]   Feasibility of using calibrated cone-beam computed tomography scans to validate the heart dose in left breast post-mastectomy radiotherapy [J].
Tang, Bin ;
Ma, Jiabao ;
Xu, Jinghui ;
Li, Jie ;
Kang, Shengwei ;
Wang, Pei ;
Wu, Fan ;
Orlandini, Lucia Clara .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (06)
[32]   Imaging re-evaluation of the tympanic segment of the facial nerve canal using cone-beam computed tomography compared with multi-slice computed tomography [J].
Zhengyu Zhang ;
Hongxia Yin ;
Zheng Wang ;
Jing Li ;
Han Lv ;
Pengfei Zhao ;
Zhenghan Yang ;
Zhenchang Wang .
European Archives of Oto-Rhino-Laryngology, 2019, 276 :1933-1941
[33]   Technical evaluation of the cone-beam computed tomography imaging performance of a novel, mobile, gantry-based X-ray system for brachytherapy [J].
Karius, Andre ;
Karolczak, Marek ;
Strnad, Vratislav ;
Bert, Christoph .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (02)
[34]   Evaluation and Reduction of Artifacts Generated by 4 Different Root-end Filling Materials by Using Multiple Cone-beam Computed Tomography Imaging Settings [J].
Helvacioglu-Yigit, Dilek ;
Kocasarac, Husniye Demirturk ;
Bechara, Boulos ;
Noujeim, Marcel .
JOURNAL OF ENDODONTICS, 2016, 42 (02) :307-314
[35]   Small animal imaging using a flat panel detector-based cone beam computed tomography (FPD-CBCT) imaging system [J].
Conover, DL ;
Ning, R ;
Yu, Y ;
Lu, XH ;
Wood, RW ;
Reeder, JE ;
Johnson, AM .
Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 :307-318
[36]   Evaluation of a Decision Support System Developed with Deep Learning Approach for Detecting Dental Caries with Cone-Beam Computed Tomography Imaging [J].
Amasya, Hakan ;
Alkhader, Mustafa ;
Serindere, Gozde ;
Futyma-Gabka, Karolina ;
Aktuna Belgin, Ceren ;
Gusarev, Maxim ;
Ezhov, Matvey ;
Rozylo-Kalinowska, Ingrid ;
Onder, Merve ;
Sanders, Alex ;
Costa, Andre Luiz Ferreira ;
Castro Lopes, Sergio Lucio Pereira de ;
Orhan, Kaan ;
Zhou, Zhuhuang .
DIAGNOSTICS, 2023, 13 (22)
[37]   C-shaped Canal System in the Mandibular Second Molars in a Saudi Arabian Subpopulation Analyzed Using Cone-Beam Computed Tomography [J].
Algarni, Youssef A. ;
Alghamdi, Nuha ;
Almuashi, Ahmed A. ;
Alghobaishi, Mosa A. ;
Alqahtani, Abdullah S. ;
Bavabeedu, Shashit Shetty ;
Alaajam, Wafa Hassan .
JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2025, 17 (SUPPL 1) :S806-S808
[38]   Evaluation of condylar cortical bone thickness in patient groups with different vertical facial dimensions using cone-beam computed tomography [J].
Lo Giudice, Antonino ;
Rustico, Lorenzo ;
Caprioglio, Alberto ;
Migliorati, Marco ;
Nucera, Riccardo .
ODONTOLOGY, 2020, 108 (04) :669-675
[39]   Prospective evaluation of spinal cord and cauda equina dose constraints using cone beam computed tomography (cbct) image guidance for spine radiosurgery [J].
Gerszten, Peter C. ;
Quader, Mubina ;
Novotny, Josef, Jr. ;
Flickinger, John C. .
JOURNAL OF RADIOSURGERY AND SBRT, 2011, 1 (03) :197-202
[40]   An approach of exposure dose reduction of cone-beam computed tomography in an image guided patient positioning system by using various noise suppression filters [J].
Kamezawa, Hidemi ;
Arimura, Hidetaka ;
Shirieda, Katsutoshi ;
Kameda, Noboru ;
Ohki, Masafumi .
2014 JOINT 7TH INTERNATIONAL CONFERENCE ON SOFT COMPUTING AND INTELLIGENT SYSTEMS (SCIS) AND 15TH INTERNATIONAL SYMPOSIUM ON ADVANCED INTELLIGENT SYSTEMS (ISIS), 2014, :1475-1480