Evaluation of imaging dose for the cone beam computed tomography system of the ring-shaped radiotherapy unit using the different International Electrotechnical Commission approaches

被引:1
作者
Wang, Qingxin [1 ,2 ,3 ]
Li, Qifeng [1 ]
Wang, Zhongqiu [2 ]
Qu, Chengbin [2 ]
Wang, Yufei [2 ]
Zhang, Wenwen [2 ]
Li, Chunyin [2 ]
Zhao, Zhonglu [2 ]
Wang, Wei [2 ]
Sa, Yu [4 ]
机构
[1] Tianjin Univ, Sch Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Tianjin Med Univ Canc Inst & Hosp, Key Lab Canc Prevent & Therapy, Natl Clin Res Ctr Canc, Dept Radiat Oncol,Tianjins Clin Res Ctr Canc, Tianjin 300060, Peoples R China
[3] Hetian Dist Peoples Hosp, Dept Med Oncol, Hetian 848000, Xinjiang, Peoples R China
[4] Tianjin Univ, Med Sch, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Cone beam CT; Radiotherapy; Imaging dose; Computed tomography dose index; Halcyon; DNA-DAMAGE; RADIATION; CT; ACCUMULATION; DOSIMETRY; CBCT;
D O I
10.1016/j.radphyschem.2024.112165
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Purpose: Daily imaging is mandatory for the Halcyon and Ethos, which are the new ring-shaped radiotherapy units. This study quantified the imaging dose of the cone beam computed tomography (CBCT) system of the new ring-shaped radiotherapy units using the latest International Electrotechnical Commission (IEC) measurement approach. Furthermore, we investigated the influence of collimation width on the imaging dose and compared the imaging dose values obtained using three IEC measurement approaches. Methods: The IEC has proposed three approaches for measuring CTDI100: traditional, transition, and the latest measurement approach. In addition to the dose measured on the CTDI phantom, the latest IEC approach uses correction factors measured in free air for CTDI100 measurement. The imaging dose was measured for all scanning protocols using the latest IEC approach. To investigate the influence of the collimation width on the imaging dose, the associated dose metric values were evaluated and compared using different IEC approaches to increase the collimation width (2-28 cm). Furthermore, the imaging system output stability was evaluated by repeated measurements. Results: In the repeated measurements, the standard deviation of CTDIw value for the pelvis and head protocol was 0.05 mGy and 0.01 mGy, respectively. And the coefficient of variation was 0.21% and 0.23%, respectively. The measured CTDIw values of the clinical protocols were higher than the vendor-provided value, except for the pelvis protocol. The value of CTDIw changes little with increasing collimation width using the latest IEC approach. The traditional and transition approaches either underestimated or overestimated the value of CTDIw, as measured by the latest IEC approach, with increasing collimation width. Conclusions: The new ring-shaped radiotherapy units imaging system has good output stability. The CTDIw values measured for clinical scanning protocols generally exceeded the vendor-provided values. Compared with the latest IEC CTDI100 measurement approach, the traditional and transition measurement approaches were more influenced by beam width. For wide CBCT scans, rationalizing the choice of imaging dose measurement approach is important.
引用
收藏
页数:8
相关论文
共 50 条
[1]   Radiation dose measurements during kilovoltage-cone beam computed tomography imaging in radiotherapy [J].
Kumar, A. Sathish ;
Singh, I. Rabi Raja ;
Sharma, Sunil Dutt ;
John, Subhashini ;
Ravindran, B. Paul .
JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2016, 12 (02) :858-863
[2]   Evaluation of a cone-beam computed tomography system calibrated for accurate radiotherapy dose calculation [J].
Bogowicz, Marta ;
Lustermans, Didier ;
Taasti, Vicki Trier ;
Hazelaar, Colien ;
Verhaegen, Frank ;
Fonseca, Gabriel Paiva ;
van Elmpt, Wouter .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 29
[3]   A comprehensive evaluation of angular range and separation on image quality, image registration, and imaging dose for cone beam computed tomography in radiotherapy [J].
Men, Kuo ;
Dai, Jianrong .
MEDICAL DOSIMETRY, 2019, 44 (01) :67-73
[4]   EVALUATION OF THYROID RADIATION DOSE USING CONE BEAM COMPUTED TOMOGRAPHY [J].
Penteado Setti da Rocha, Anna Silvia ;
Aguiar, Guilherme de Mello ;
Tulio, Ana Paula ;
Ditzel, Alessandra S. ;
Filipov, Danielle .
RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) :368-372
[5]   EVALUATION OF RADIATION DOSE AND IMAGE QUALITY FOR THE VARIAN CONE BEAM COMPUTED TOMOGRAPHY SYSTEM [J].
Cheng, Harry C. Y. ;
Wu, Vincent W. C. ;
Liu, Eva S. F. ;
Kwong, Dora L. W. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01) :291-300
[6]   Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography [J].
Chau, Anson C. M. ;
Fung, Karl .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (04) :559-565
[7]   Imaging dose of cone-beam computed tomography in nanoparticle-enhanced image-guided radiotherapy: A Monte Carlo phantom study [J].
Mututantri-Bastiyange, Dewmini ;
Chow, James C. L. .
AIMS BIOENGINEERING, 2020, 7 (01) :1-11
[8]   Evaluation of dose from kV cone-beam computed tomography during radiotherapy: a comparison of methodologies [J].
Buckley, J. ;
Wilkinson, D. ;
Malaroda, A. ;
Metcalfe, P. .
MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
[9]   Dose calculation accuracy of clinical radiotherapy plans using next generation cone beam computed tomography imaging technology [J].
Martin, Peter R. ;
Cherpak, Amanda ;
MacDonald, R. Lee ;
Yashayaeva, Abigail ;
McAloney, David ;
McMaster, Natasha ;
Zhan, Kenny ;
Cwajna, Slawa ;
Patil, Nikhilesh ;
Dahn, Hannah M. ;
Robar, James L. .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2025, 34
[10]   EVALUATION OF CANINE PROSTATE INTRAFRACTIONAL MOTION USING SERIAL CONE BEAM COMPUTED TOMOGRAPHY IMAGING [J].
Harmon, Joseph, Jr. ;
Yoshikawa, Hiroto ;
Custis, James ;
LaRue, Susan .
VETERINARY RADIOLOGY & ULTRASOUND, 2013, 54 (01) :93-98