Objective To introduce a novel universal guide design for distal femoral osteotomy (DFO) to treat femoral deformities and other hindlimb orthopaedic diseases, and to compare its accuracy to the patient-specific guide in vitro and ex vivo on X-ray and computed tomography (CT). Methods Thirteen anatomic specimens of canine femurs and 13 3D-printed femoral bone models were subjected to DFO using a patient-specific and a universal guide. The anatomical lateral distal femoral angle and anteversion angle were measured on radiographic and CT images before and after surgical procedure and used to compare the accuracy of the surgical guides in treating uniplanar or biplanar deformities. Bone models were used to compare the accuracy with ex vivo models. Results The mean correction errors were -1.18 degrees to 0.72 degrees on X-ray and -1.91 degrees to 0.53 degrees on CT scan. The analysis showed no statistically significant difference in the mean error between the groups based on type of guide used, nor in the mean error between groups based on whether anteversion correction was performed based on both the CT and X-ray imaging data. Conclusion Both the patient-specific and universal guides can produce accurate results in DFO surgery, and the universal guide shows potential as a useful surgical tool.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Computer-aided Design and Custom-made Guide in Corrective Osteotomy for Complex Femoral Deformity
    柴伟
    许猛
    张国强
    张立海
    苟文隆
    倪明
    陈继营
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2013, 33 (03) : 398 - 405
  • [32] Patient specific surgical guide design and application in preoperative planning for femoral head necrosis using computer aided design
    Zhang, Ying
    He, Jianling
    Yang, Yuxia
    Zhang, Leilei
    Ma, Xianghao
    Liu, Youwen
    Tian, Kewei
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (04): : 1814 - 1819
  • [33] Computer-aided design and custom-made guide in corrective osteotomy for complex femoral deformity
    Wei Chai
    Meng Xu
    Guo-qiang Zhang
    Li-hai Zhang
    Wen-long Gou
    Ming Ni
    Ji-ying Chen
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2013, 33 : 398 - 405
  • [34] Analysis of the Technical Accuracy of a Patient-Specific Stereotaxy Platform for Brain Biopsy
    Mueller, Marcel
    Winkler, Dirk
    Moebius, Robert
    Werner, Michael
    Drossel, Welf-Guntram
    Gueresir, Erdem
    Grunert, Ronny
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (02):
  • [35] Biomechanical Study on the Efficacy of the Periacetabular Osteotomy using Patient-specific Finite Element Analysis
    Lee, Kyung-Jin
    Park, Sung-Jae
    Lee, Sung-Jae
    Naito, Masatoshi
    Kwon, Soon-Yong
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (04) : 823 - 829
  • [36] Early experience using patient-specific instrumentation in opening wedge high tibial osteotomy
    Predescu, Vlad
    Grosu, Alina-Maria
    Gherman, Iulian
    Prescura, Catalin
    Hiohi, Valentin
    Deleanu, Bogdan
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (06) : 1509 - 1515
  • [37] Computer-aided design and custom-made guide in corrective osteotomy for complex femoral deformity
    Chai, Wei
    Xu, Meng
    Zhang, Guo-qiang
    Zhang, Li-hai
    Gou, Wen-long
    Ni, Ming
    Chen, Ji-ying
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2013, 33 (03) : 398 - 405
  • [38] Biomechanical study on the efficacy of the periacetabular osteotomy using Patient-specific finite element analysis
    Kyung-Jin Lee
    Sung-Jae Park
    Sung-Jae Lee
    Masatoshi Naito
    Soon-Yong Kwon
    International Journal of Precision Engineering and Manufacturing, 2015, 16 : 823 - 829
  • [39] Accuracy of patient-specific instrumentation in anatomic and reverse total shoulder arthroplasty
    Dallalana, Richard James
    McMahon, Ryan A.
    East, Ben
    Geraghty, Liam
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2016, 10 (02): : 59 - 66
  • [40] Accuracy of Placement of Pedicle Screws in the Lumbosacral Region of Dogs Using 3D-Printed Patient-Specific Drill Guides
    Toni, Cristina
    Oxley, Bill
    Clarke, Stephen
    Behr, Sebastien
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2021, 34 (01) : 53 - 58