Comparing the Accuracy of Patient-Specific Guide and Universal Guide for Distal Femoral Osteotomy in Dogs

被引:0
|
作者
Cheon, Jaeeon [1 ]
Kang, Jinsu [2 ]
Kim, Namsoo [1 ]
Heo, Suyoung [1 ]
机构
[1] Jeonbuk Natl Univ, Coll Vet Med, Dept Vet Surg, Iksan, South Korea
[2] Kyungpook Natl Univ, Coll Vet Med, Dept Vet Surg, Daegu, South Korea
关键词
distal femoral osteotomy; femoral deformity; patient-specific; universal guide; dogs; MEDIAL PATELLAR LUXATION; VARUS; DEFORMITIES; FRACTURE;
D O I
10.1055/s-0044-1790219
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To introduce a novel universal guide design for distal femoral osteotomy (DFO) to treat femoral deformities and other hindlimb orthopaedic diseases, and to compare its accuracy to the patient-specific guide in vitro and ex vivo on X-ray and computed tomography (CT). Methods Thirteen anatomic specimens of canine femurs and 13 3D-printed femoral bone models were subjected to DFO using a patient-specific and a universal guide. The anatomical lateral distal femoral angle and anteversion angle were measured on radiographic and CT images before and after surgical procedure and used to compare the accuracy of the surgical guides in treating uniplanar or biplanar deformities. Bone models were used to compare the accuracy with ex vivo models. Results The mean correction errors were -1.18 degrees to 0.72 degrees on X-ray and -1.91 degrees to 0.53 degrees on CT scan. The analysis showed no statistically significant difference in the mean error between the groups based on type of guide used, nor in the mean error between groups based on whether anteversion correction was performed based on both the CT and X-ray imaging data. Conclusion Both the patient-specific and universal guides can produce accurate results in DFO surgery, and the universal guide shows potential as a useful surgical tool.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Accuracy of patient-specific three-dimensional-printed osteotomy and reduction guides for distal femoral osteotomy in dogs with medial patella luxation
    Hall, Emma L.
    Baines, Stephen
    Bilmont, Alexis
    Oxley, Bill
    VETERINARY SURGERY, 2019, 48 (04) : 584 - 591
  • [2] Clinical accuracy of a patient-specific femoral osteotomy guide in minimally-invasive posterior hip arthroplasty
    Schneider, Adrian K.
    Pierrepont, Jim W.
    Hawdon, Gabrielle
    McMahon, Stephen
    HIP INTERNATIONAL, 2018, 28 (06) : 636 - 641
  • [3] Small changes of femoral torsion in varus or valgus distal femoral osteotomy using patient-specific instruments
    Jud, Lukas
    Neopoulos, Georgios
    Hodel, Sandro
    Vlachopoulos, Lazaros
    Fucentese, Sandro F.
    INTERNATIONAL ORTHOPAEDICS, 2025, 49 (03) : 621 - 627
  • [4] Three-dimensional computer-assisted corrective osteotomy with a patient-specific surgical guide for an antebrachial limb deformity in two dogs
    Longo, F.
    Penelas, A.
    Gutbrod, A.
    Pozzi, A.
    SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 2019, 161 (7-8): : 473 - 479
  • [5] Patient-Specific 3D-Printed Osteotomy Guides and Titanium Plates for Distal Femoral Deformities in Dogs with Lateral Patellar Luxation
    Panichi, Enrico
    Cappellari, Fulvio
    Burkhan, Ekaterina
    Principato, Gaetano
    Currenti, Marco
    Tabbi, Marco
    Macri, Francesco
    ANIMALS, 2024, 14 (06):
  • [6] Combined Correction of Coronal and Rotational Deformities of the Femur With Distal Femoral Osteotomy Using Patient-Specific Instrumentation
    Neopoulos, Georgios
    Jud, Lukas
    Vlachopoulos, Lazaros
    Fucentese, Sandro F.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2025, 53 (04) : 848 - 854
  • [7] Three-dimensional corrective osteotomy using a patient-specific osteotomy guide and bone plate based on a computer simulation system: accuracy analysis in a cadaver study
    Omori, Shinsuke
    Murase, Tsuyoshi
    Kataoka, Toshiyuki
    Kawanishi, Yohei
    Oura, Keiichiro
    Miyake, Junichi
    Tanaka, Hiroyuki
    Yoshikawa, Hideki
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2014, 10 (02) : 196 - 202
  • [8] Accuracy and Efficacy of a Patient-Specific Drill Guide Template System for Lumbosacral Junction Fixation in Medium and Small Dogs: Cadaveric Study and Clinical Cases
    Fujioka, Toru
    Nakata, Kohei
    Nakano, Yukiko
    Nozue, Yuta
    Sugawara, Taku
    Konno, Naoyuki
    Maeda, Sadatoshi
    Kamishina, Hiroaki
    FRONTIERS IN VETERINARY SCIENCE, 2020, 6
  • [9] Accuracy of a patient-specific 3D printed drill guide for placement of cervical transpedicular screws
    Hamilton-Bennett, Sinead E.
    Oxley, Bill
    Behr, Sebastien
    VETERINARY SURGERY, 2018, 47 (02) : 236 - 242
  • [10] Accuracy of intertrochanteric osteotomy for patients with slipped capital femoral epiphysis operated with 3D printed patient-specific guides
    van den Boorn, M.
    Dobbe, J. G. G.
    Lagerburg, V.
    Witbreuk, M. M. E. H.
    Streekstra, G. J.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):