Neutron Spectroscopy in Perpendicular Neutral Beam Injection Deuterium Plasmas Using Newly Developed Compact Neutron Emission Spectrometers

被引:1
作者
Sangaroon, Siriyaporn [1 ]
Ogawa, Kunihiro [2 ]
Isobe, Mitsutaka [2 ]
Liao, Longyong [3 ]
Zhong, Guoqiang [4 ]
Wisitsorasak, Apiwat [5 ]
Takada, Eiji [6 ]
Kobayashi, Makoto Inami [2 ]
Poolyarat, Nopporn [7 ]
Murakami, Sadayoshi [8 ]
Seki, Ryohsuke [2 ]
Nuga, Hideo [2 ]
Osakabe, Masaki [2 ]
机构
[1] Mahasarakham Univ, Fac Sci, Dept Phys, Maha Sarakham 44150, Thailand
[2] Natl Inst Fus Sci, Toki 5095202, Japan
[3] Grad Univ Adv Studies, Dept Res, SOKENDAI, Hayama 5095202, Japan
[4] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
[5] King Mongkuts Univ Technol Thonburi, Fac Sci, Dept Phys, Bangkok 10140, Thailand
[6] Natl Inst Technol, Tokyo 1010003, Japan
[7] Thailand Inst Nucl Technol, Bangkok 10900, Thailand
[8] Kyoto Univ, Dept Nucl Engn, Kyoto 6158540, Japan
关键词
Ions; Neutrons; Plasmas; Heating systems; Particle beams; Particle beam injection; Detectors; Compact neutron emission spectrometer (CNES); Cs2LiYCl6:Ce scintillation detector enriched with Li-7 (CLYC7); EJ-301; ion cyclotron range of frequency (ICRF) wave; large helical device (LHD); neutral beam (NB) injection; ENERGY-SPECTRA; JET; SCINTILLATOR; DETECTORS; CS2LIYCL6;
D O I
10.1109/TIM.2024.3446631
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The presence of helically trapped fast ions in helical ripples in the large helical device (LHD), resulting from a perpendicularly injected positive-ion-source-based neutral beam (P-NB)-heated plasma and/or from ion cyclotron range of frequency (ICRF) wave-heated plasma, poses a significant concern due to the system's lack of symmetry. In response to this challenge, compact neutron emission spectrometers (CNESs) have been strategically developed in the LHD, featuring a perpendicular line of sight relative to the plasma's magnetic field. The first perpendicular CNES offered a vertical field of view through the deuterium plasma and incorporated a liquid (EJ-301) scintillation detector optimized for efficient operation at a high neutron emission rate. The second perpendicular CNES was operated using a Cs2LiYCl6:Ce scintillation detector enriched with 7Li (CLYC7), providing a horizontal field of view through the deuterium plasma and effectively operating in a region characterized by relatively low neutron emission rates. During plasma heating through P-NB, both perpendicular CNESs showed a neutron energy distribution, featuring a double-humped profile with two peaks at energy of approximately 2.30 and 2.74 MeV. Furthermore, the deuterium-deuterium neutron energy spectrum expected to be obtained by perpendicular CNES was calculated using the 5-D orbit following code DELTA5D and considering the Larmor motion effect. The results revealed that the experimentally obtained neutron energies were almost consistent with the neutron energies calculated based on the orbit following model. These peaks aligned with the Larmor motion of deuterons resulting from P-NB injection at the helical ripple of the LHD. In addition, we conducted neutron spectroscopy involving deuterium-deuterium interactions in a deuterium plasma simultaneously heated by both P-NB and ICRF wave, characterized by a high neutron emission rate, using perpendicular CNES based on EJ-301. The observation revealed a broadening in spectrum width, attributed to the additional ICRF wave heating.
引用
收藏
页数:11
相关论文
共 73 条
  • [1] APV_ADC, about us
  • [2] FUSION NEUTRON ENERGIES AND SPECTRA
    BRYSK, H
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 1973, 15 (07) : 611 - 617
  • [3] Single crystal diamond detector measurements of deuterium-deuterium and deuterium-tritium neutrons in Joint European Torus fusion plasmas
    Cazzaniga, C.
    Sunden, E. Andersson
    Binda, F.
    Croci, G.
    Ericsson, G.
    Giacomelli, L.
    Gorini, G.
    Griesmayer, E.
    Grosso, G.
    Kaveney, G.
    Nocente, M.
    Cippo, E. Perelli
    Rebai, M.
    Syme, B.
    Tardocchi, M.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (04)
  • [4] Fast neutron response of 6Li-depleted CLYC detectors up to 20 MeV
    D'Olympia, N.
    Chowdhury, P.
    Jackson, E. G.
    Lister, C. J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 763 : 433 - 441
  • [5] Optimizing Cs2LiYCl6 for fast neutron spectroscopy
    D'Olympia, N.
    Chowdhury, P.
    Guess, C. J.
    Harrington, T.
    Jackson, E. G.
    Lakshmi, S.
    Lister, C. J.
    Glodo, J.
    Hawrami, R.
    Shah, K.
    Shirwadkar, U.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 694 : 140 - 146
  • [6] eljentechnology, EJ301
  • [7] Neutron emission spectroscopy at JET -: Results from the magnetic proton recoil spectrometer (invited)
    Ericsson, G
    Ballabio, L
    Conroy, S
    Frenje, J
    Henriksson, H
    Hjalmarsson, A
    Källne, J
    Tardocchi, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01) : 759 - 766
  • [8] Advanced Neutron Spectroscopy in Fusion Research
    Ericsson, Goran
    [J]. JOURNAL OF FUSION ENERGY, 2019, 38 (3-4) : 330 - 355
  • [9] Chapter 5: Physics of energetic ions
    Fasoli, A.
    Gormenzano, C.
    Berk, H. L.
    Breizman, B.
    Briguglio, S.
    Darrow, D. S.
    Gorelenkov, N.
    Heidbrink, W. W.
    Jaun, A.
    Konovalov, S. V.
    Nazikian, R.
    Noterdaeme, J.-M.
    Sharapov, S.
    Shinohara, K.
    Testa, D.
    Tobita, K.
    Todo, Y.
    Vlad, G.
    Zonca, F.
    [J]. NUCLEAR FUSION, 2007, 47 (06) : S264 - S284
  • [10] Neutron emission Doppler-shift measurements in deuterium-tritium plasmas
    Frenje, J
    Ballabio, L
    Conroy, S
    Ericsson, G
    Gorini, G
    Källne, J
    Prandoni, P
    Tardocchi, M
    Traneus, E
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) : 1176 - 1180