Five-Year Outcomes of Measured and Predicted Prosthesis-Patient Mismatch following Transcatheter Aortic Valve Implantation

被引:1
作者
Al-Azizi, Karim [1 ]
Moubarak, Ghadi [2 ]
Mohiuddin, Asim [2 ]
Szerlip, Molly [1 ,2 ]
Potluri, Srinivasa [1 ]
Harrington, Katherine [3 ]
Schaffer, Justin [3 ]
Brinkman, William [3 ]
Alsaid, Amro [1 ]
Wang, Zuyue [1 ]
Ladner, Jonathan [2 ]
Gunukula, Rahul [2 ]
Parro, Colleen [2 ]
Ma, Tsung-Wei [2 ]
Stoler, Robert [4 ]
Chugh, Yashasvi [4 ]
Banerjee, Subhash [4 ]
Mixon, Timothy [5 ]
Widmer, Robert J. [5 ]
Caldera, Angel [6 ]
Contreras, Jose Condado [6 ]
Krueger, Anita [7 ]
Gray, William [8 ]
DiMaio, J. Michael [2 ,3 ]
Mack, Michael J. [2 ,5 ]
机构
[1] Baylor Scott & White Heart Hosp, Dept Cardiol, Plano, TX 75093 USA
[2] Baylor Scott & White Res Inst, Plano, TX USA
[3] Baylor Scott & White Heart Hosp, Dept Cardiothorac Surg, Plano, TX USA
[4] Baylor Univ, Med Ctr, Dept Cardiol, Dallas, TX USA
[5] Baylor Scott & White Med Ctr, Dept Cardiol, Temple, TX USA
[6] Baylor Scott & White Med Ctr, Dept Cardiol, Round Rock, TX USA
[7] Baylor Scott & White All St Med Ctr, Dept Cardiothorac Surg, Ft Worth, TX USA
[8] Baylor Scott & White Med Ctr, Dept Cardiol, College Stn, TX USA
关键词
effective orifice area; measured prosthesis-patient mismatch; outcomes; predicted prosthesis-patient mismatch; transcatheter aortic valve replacement; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; RISK PATIENTS; REPLACEMENT; ECHOCARDIOGRAPHY; RECOMMENDATIONS; METAANALYSIS; STENOSIS; IMPACT; TRIAL;
D O I
10.1016/j.amjcard.2024.08.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Data on the long-term outcomes of prosthesis patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) remain controversial. This study aimed to investigate the incidence and clinical outcomes of measured PPM (PPMM) and predicted PPM (PPMP) in patients who underwent TAVI. This is a retrospective analysis of 3,016 patients who underwent TAVI at a large health care system between 2012 and 2021. Effective orifice area indexed to body surface area (EOAi) was measured at discharge using the continuity equation. EOAi was predicted according to the published predictive tables for each model and size of the valve. Primary end point was 5-year survival rate. Mean age was 80 years, and 55.6% were male. The mean Society of Thoracic Surgeons risk score was 4.66%. 74.9% of patients received a balloon-expandable valve (BEV), and 25.1% received a self-expanding valve (SEV). The incidence of severe PPM was markedly lower when defined by predicted versus measured EOAi (0.8% vs 6.3%, p <0.001) and when assessed in SEV versus BEV (5.3% vs 6.6%, p = 0.02). Neither severe PPMp nor severe PPMM was associated with 5-year mortality (hazard ratio 1.26, 95% confidence interval 0.96 to 1.66, p = 0.095; hazard ratio 1.03, 95% confidence interval 0.42 to 2.49, p = 0.954, respectively), irrespective of the presence of high residual pressure gradient. Neither BEV nor SEV was associated with an increased 5-year mortality, irrespective of PPM definition or severity. In this large health care system analysis, neither severe PPMP nor severe PPMM was associated with 5-year all-cause mortality. There was no difference between BEV and SEV in terms of mortality, irrespective of the definition or severity of PPM.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 25 条
[1]   Impact of Flow on Prosthesis-Patient Mismatch Following Transcatheter and Surgical Aortic Valve Replacement [J].
Abbas, Amr E. ;
Ternacle, Julien ;
Pibarot, Philippe ;
Xu, Ke ;
Alu, Maria ;
Rogers, Erin ;
Hahn, Rebecca T. ;
Leon, Martin ;
Thourani, Vinod H. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2021, 14 (08) :E012364
[2]   Hemodynamic principles of prosthetic aortic valve evaluation in the transcatheter aortic valve replacement era [J].
Abbas, Amr E. ;
Mando, Ramy ;
Hanzel, George ;
Goldstein, James ;
Shannon, Francis ;
Pibarot, Philippe .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (05) :738-757
[3]   Invasive Versus Echocardiographic Evaluation of Transvalvular Gradients Immediately Post-Transcatheter Aortic Valve Replacement Demonstration of Significant Echocardiography-Catheterization Discordance [J].
Abbas, Amr E. ;
Mando, Ramy ;
Hanzel, George ;
Gallagher, Michael ;
Safian, Robert ;
Hanson, Ivan ;
Almany, Steven ;
Pibarot, Philippe ;
Dalal, Pratik ;
Vivacqua, Alessandro ;
Sakwa, Marc ;
Shannon, Francis .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (07)
[4]   Clinical and Echocardiographic Characteristics of Flow-Based Classification Following Balloon-Expandable Transcatheter Heart Valve in PARTNER Trials [J].
Akinmolayemi, Oludamilola ;
Ozdemir, Denizhan ;
Pibarot, Philippe ;
Zhao, Yanglu ;
Leipsic, Jonathon ;
Douglas, Pamela S. ;
Jaber, Wael A. ;
Weissman, Neil J. ;
Blanke, Philipp ;
Hahn, Rebecca T. .
JACC-CARDIOVASCULAR IMAGING, 2023, 16 (01) :1-9
[5]   Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement [J].
Dayan, Victor ;
Vignolo, Gustavo ;
Soca, Gerardo ;
Paganini, Juan Jose ;
Brusich, Daniel ;
Pibarot, Philippe .
JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) :924-933
[6]   The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement [J].
Fallon, John M. ;
DeSimone, Joseph P. ;
Brennan, J. Matthew ;
O'Brien, Sean ;
Thibault, Dylan P. ;
DiScipio, Anthony W. ;
Pibarot, Philippe ;
Jacobs, Jeffrey P. ;
Malenka, David J. ;
Clarizia, Nadia A. ;
Ruel, Marc .
ANNALS OF THORACIC SURGERY, 2018, 106 (01) :14-23
[7]  
Généreux P, 2021, EUR HEART J, V42, P1825, DOI [10.1093/eurheartj/ehaa799, 10.1016/j.jacc.2021.02.038]
[8]   Comprehensive Echocardiographic Assessment of Normal Transcatheter Valve Function [J].
Hahn, Rebecca T. ;
Leipsic, Jonathon ;
Douglas, Pamela S. ;
Jaber, Wael A. ;
Weissman, Neil J. ;
Pibarot, Philippe ;
Blanke, Philipp ;
Oh, Jae K. .
JACC-CARDIOVASCULAR IMAGING, 2019, 12 (01) :25-34
[9]   Incidence, predictors, and outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement A meta-analysis [J].
He, Shixin ;
Fang, Zhenfei .
MEDICINE, 2020, 99 (24) :E20717
[10]   The impact of prosthesispatient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years [J].
Head, Stuart J. ;
Mokhles, Mostafa M. ;
Osnabrugge, Ruben L. J. ;
Pibarot, Philippe ;
Mack, Michael J. ;
Takkenberg, Johanna J. M. ;
Bogers, Ad J. J. C. ;
Kappetein, Arie Pieter .
EUROPEAN HEART JOURNAL, 2012, 33 (12) :1518-1529