Comparative analysis of electrophoresis and interferometric optical detection method for molecular weight determination of proteins

被引:0
作者
Santamaria, B. [1 ,2 ,3 ]
Hernandez, A. L. [1 ,2 ]
Laguna, M. F. [1 ,2 ,4 ]
Holgado, M. [1 ,2 ,4 ]
机构
[1] Univ Politecn Madrid, Ctr Biomed Technol CTB, Grp Opt Photon & Biophoton, Parque Cientif & Tecnol UPM,Campus Montegancedo,M-, Madrid 28223, Spain
[2] Hosp Clin San Carlos IdISSC, Grp Organ & Tissue On a chip & Invitro Detect, Hlth Res Inst, C Prof Martin Lagos s-n,4a Planta Sur, Madrid 28040, Spain
[3] Univ Politecn Madrid, Escuela Super Ingn & Diseno Ind, Dept Mech Chem & Ind Design Engn, Ronda Valencia 3, Madrid 28012, Spain
[4] Univ Politecn Madrid, Escuela Tecn Super Ingn Ind, Dept Appl Phys & Mat Engn, C Jose Gutierrez Abascal 2, Madrid 28006, Spain
关键词
Molecular mass; Molecular weight; Electrophoresis; Biosensor; Interferometric optical detection method;
D O I
10.1016/j.heliyon.2024.e35932
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Analytical detection methods play a pivotal role in scientific research, enabling the identification and quantification of specific analytes in various disciplines. This scientific report aims to compare two very different methodologies for determining the Molecular Mass (MM, also known as Molecular Weight, MW) of proteins: electrophoresis gel and the Interferometric Optical Detection Method (IODM). For this purpose, several proteins with different MM were selected. The electrophoresis technique was employed to validate the structure and MM of different parts or fragments of the Matrix Metallopeptidase 9 antibody (anti-MMP9), antibody against S100 calcium binding protein A6 (anti-S100A6) and Cystatin S4 antibody (anti-CST4) by examining the presence of bands with expected sizes. The IODM was applied to study the above-mentioned proteins (part of the antibodies) together with the protein G, as a reference to correlate the MM and protein sizes with the measured signal. We report the evidence of IODM as a competitive analytical approach for the determination of the MM of proteins for the first time. This innovative method allows for accurate MM determination using minimal sample volumes and concentrations, employing a simple experimental procedure that eliminates the requirement for protein denaturation.
引用
收藏
页数:8
相关论文
共 21 条
  • [1] Barril P, 2012, GEL ELECTROPHORESIS - PRINCIPLES AND BASICS, P3
  • [2] calctool, CalcTool: protein size from MWt calculator
  • [3] Engineering vertically interrogated interferometric sensors for optical label-free biosensing
    Casquel, Rafael
    Holgado, Miguel
    Laguna, Maria F.
    Hernandez, Ana L.
    Santamaria, Beatriz
    Lavin, Alvaro
    Tramarin, Luca
    Herreros, Pedro
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (14) : 3285 - 3297
  • [4] POLYACRYLAMIDE GEL ELECTROPHORESIS
    CHRAMBACH, A
    RODBARD, D
    [J]. SCIENCE, 1971, 172 (3982) : 440 - +
  • [5] Davis R.E., 2009, Modern Chemistry, No. 540 M689m, P2002
  • [6] Size and Shape of Protein Molecules at the Nanometer Level Determined by Sedimentation, Gel Filtration, and Electron Microscopy
    Erickson, Harold P.
    [J]. BIOLOGICAL PROCEDURES ONLINE, 2009, 11 (01): : 32 - 51
  • [7] Reliability of the retention factor estimations in liquid chromatography
    Escuder-Gilabert, L
    Bermúdez-Saldaña, JM
    Villanueva-Camañas, RM
    Medina-Hernández, MJ
    Sagrado, S
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) : 247 - 255
  • [8] Fritsch R.J., 2003, Encyclopedia of Food Sciences and Nutrition, VSecond, P2055, DOI DOI 10.1016/B0-12-227055-X/01409-7
  • [9] Graphene-Based Fabry-Perot Resonator for Chemical Sensing Applications at Mid-Infrared Frequencies
    Ghods, Mohammad Mahdi
    Rezaei, Pejman
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2018, 30 (22) : 1917 - 1920
  • [10] Goetz H, 2004, J BIOCHEM BIOPH METH, V60, P281, DOI 10.1016/j.jbbm.2004.01.007