Simultaneous quantification of icaritin and its novel 3-methylcarbamate prodrug in rat plasma using HPLC-MS/MS and its application to pharmacokinetic study

被引:0
|
作者
Li, Fengxiao [1 ]
Wang, Weiping [1 ]
Zhai, Yixiu [1 ]
Fan, Jiaqi [1 ]
Jiang, Qikun [1 ,2 ]
Zhang, Tianhong [1 ]
机构
[1] Shenyang Pharmaceut Univ, Wuya Coll Innovat, Shenyang 110016, Peoples R China
[2] Shenyang Pharmaceut Univ, Joint Int Res Lab Intelligent Drug Delivery Syst, Shenyang 110016, Peoples R China
基金
中国国家自然科学基金;
关键词
carbamate; HPLC-MS/MS; icaritin; pharmacokinetic; prodrug; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; ORAL ABSORPTION; GLUCURONIDATION; METABOLITES; EXCRETION;
D O I
10.1002/bmc.5976
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive, rapid, and simple HPLC-MS/MS method was first developed and fully validated to determine the icaritin (ICT) and its novel 3-methylcarbamate prodrug (3N) simultaneously in rat plasma. Analytes were extracted from rat plasma using a liquid-liquid extraction (LLE) method. Chromatographic separation was performed on ACE Excel 2 C18-Amide column. Quantitation of analytes was conducted on an LCMS-8060 triple-quadrupole tandem mass spectrometer. The quantitation mode was the multiple reaction monitoring via positive electrospray ionization. The calibration curve was linear over the concentration range of 1 to 200 ng/ml for ICT with a correlation coefficient of r = 0.9950 and 1 to 400 ng/ml for 3N with a correlation coefficient of r = 0.9956. The intra-precision RSDs were <= 12% for ICT and 3N. The inter-day precision RSDs were <= 10% for ICT and 3N. The accuracy RE was between -2.6% and 7.8% for ICT and 3N. The average ICT, 3N and IS recoveries were 87.9%, 83.6%, and 84.3%. The plasma matrix of ICT and 3N complied with the guidelines. ICT and 3N were stable in rat plasma under various tested conditions. This work has been successfully applied to studying the pharmacokinetics of ICT and 3N.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Simultaneous Determination of Luteolin and Ayanin in Rat Plasma by HPLC-MS-MS and its Application in a Pharmacokinetic Study
    Li, Li
    Liang, Ji-Jun
    Liu, Yu
    Chen, Li-Jiang
    Zhang, Wen-Jun
    Lu, En
    LATIN AMERICAN JOURNAL OF PHARMACY, 2014, 33 (09): : 1475 - 1480
  • [22] A Sensitive HPLC-MS/MS Method for the Quantification of Selegiline Beagle Dog Plasma: Application to a Pharmacokinetic Study
    Liu, Hongrui
    Chen, Fang
    Wang, Bing
    Wang, Hao
    Jin, Shasha
    Yang, Zhou
    Chen, Yusheng
    Quan, Yingjun
    Xiang, Xiaoqiang
    CURRENT PHARMACEUTICAL ANALYSIS, 2021, 17 (01) : 140 - 148
  • [23] Determination of fenticonazole in human plasma by HPLC-MS/MS and its application to pharmacokinetic studies
    Mao, Weixing
    Wang, Yiya
    Hu, Wenhui
    Jiao, Feifei
    Fan, Hongwei
    Ding, Li
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2017, 7 (01) : 63 - 70
  • [24] Quantification of Apixaban in Rat Plasma Using UPLC-MS/MS and its Application to a Pharmacokinetic Study
    Jin, Xian-guan
    Yang, Yan-yang
    Hu, Ming-lei
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (08): : 1748 - 1753
  • [25] Quantification of Rebamipide in Human Plasma by HPLC-MS/MS and Application to A Pharmacokinetic Study in Chinese Healthy Volunteers
    Guo, Nan
    Bu, Fanlong
    Zhang, Rui
    Yuan, Guiyan
    Wang, Benjie
    Li, Rong
    Guo, Ruichen
    LATIN AMERICAN JOURNAL OF PHARMACY, 2019, 38 (09): : 1788 - 1794
  • [26] Development of a simple and rapid HPLC-MS/MS method for quantification of streptomycin in mice and its application to plasma pharmacokinetic studies
    Wang, Zhijun
    Xie, Chen
    Yeung, Steven
    Wang, Jeffrey
    Chow, Moses S. S.
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (02)
  • [27] Simultaneous determination and validation of oncrasin-266 and its metabolites by HPLC-MS/MS: Application to a pharmacokinetic study
    White, Lyndsey
    Wu, Shuhong
    Ma, Jing
    Fang, Bingliang
    Liang, Dong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1033 : 106 - 111
  • [28] ASimple and Sensitive HPLC-MS/MS Assay for the Quantitation of Blonanserin and N-Desethyl Blonanserin in Rat Plasma and Its Application to Pharmacokinetic Study
    Huang, Shan-qing
    Li, Xiao-lin
    Wang, Zhan-zhang
    Lu, Hao-yang
    Xiao, Tao
    Ni, Xiao-jia
    Liu, Shu-jing
    Zhang, Ming
    Shang, De-wei
    Wen, Yu-guan
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2022, 2022
  • [29] Quantification of endostar in rat plasma by LC-MS/MS and its application in a pharmacokinetic study
    Li, Ying Chun
    Liang, Yan
    Tang, Zhi Yuan
    Xiao, Ya Nan
    Hao, Hai Ping
    Wang, Guang Ji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 505 - 511
  • [30] Simultaneous determination of ZL-01, a novel nucleotide prodrug, and its metabolites in rat plasma by LC-MS/MS: Application to pharmacokinetic study
    Chang, Ruirui
    Xu, Si-Tao
    Jin, Hao-Wen
    Zhao, Yong-Jie
    Hu, Tian-Yu
    Wang, Guangji
    Wang, Jiankun
    Zhen, Le
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 208