Dual-side view optical coherence tomography for thickness measurement on opaque materials

被引:7
|
作者
Wu, Qian [1 ]
Wang, Xiwen [1 ]
Liu, Linbo [2 ]
Mo, Jianhua [1 ]
机构
[1] Soochow Univ, Sch Elect & Informat Engn, 1 Shizi St, Suzhou 215006, Peoples R China
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, 50 Nanyang Ave, Singapore 639798, Singapore
基金
中国国家自然科学基金;
关键词
INSPECTION;
D O I
10.1364/OL.384337
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography (OCT), as an optical interferometric imaging technique, has found wide applications in various fields. In principle, OCT is well suited for imaging layered structures, and thus, one of the typical applications is thickness measurement. However, due to the limited imaging depth resulting from light attenuation, thickness measurement by OCT is limited to non-opaque materials. In this study, we developed a novel (to the best of our knowledge) dual-side view OCT (DSV-OCT) system for thickness measurement on opaque materials. The dual-side view was achieved on a conventional swept source OCT platform by creating two symmetrical sampling arms. This allows us to image both sides of the material simultaneously and produce the surface contours of the two sides in a single C scan. Finally, the thickness of the opaque material can be calculated from the two surface contours above. We demonstrated that our DSV-OCT technique can measure the thickness of opaque material with an accuracy of about 3 mu m. (C) 2020 Optical Society of America
引用
收藏
页码:832 / 835
页数:4
相关论文
共 50 条
  • [1] Inspection of Intraocular Lens With Dual-Side View Optical Coherence Tomography
    Wu, Qian
    Wang, Xiwen
    Liu, Linbo
    Mo, Jianhua
    IEEE PHOTONICS JOURNAL, 2021, 13 (03):
  • [2] Thickness Measurement Opaque Material by Swept Source Optical Coherence Tomography
    Wu, Qian
    Dai, Jianing
    Zhu, Jie
    Wang, Xiwen
    Chen, Xinjian
    Mo, Jianhua
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS VI, 2019, 11189
  • [3] Optical coherence tomography as film thickness measurement technique
    Manallah, Aissa
    Bouafia, Mohamed
    Meguellati, Said
    PHOTONICS, DEVICES, AND SYSTEMS VI, 2015, 9450
  • [4] Measurement of the thickness of the fibrous cap by optical coherence tomography
    Kume, Teruyoshi
    Akasaka, Takashi
    Kawamoto, Takahiro
    Okura, Hiroyuki
    Watanabe, Nozomi
    Toyota, Eiji
    Neishi, Yoji
    Sukmawan, Renan
    Sadahira, Yoshito
    Yoshida, Kiyoshi
    AMERICAN HEART JOURNAL, 2006, 152 (04) : 755.e1 - 755.e4
  • [5] Measurement of Oral Epithelial Thickness by Optical Coherence Tomography
    Di Stasio, Dario
    Lauritano, Dorina
    Iquebal, Hasan
    Romano, Antonio
    Gentile, Enrica
    Lucchese, Alberta
    DIAGNOSTICS, 2019, 9 (03)
  • [6] Accuracy of measurement of stent strut thickness by optical coherence tomography
    Terashima, M.
    Nakayama, Y.
    Suzuki, Y.
    Habara, M.
    Katoh, O.
    Suzuki, T.
    EUROPEAN HEART JOURNAL, 2008, 29 : 684 - 684
  • [7] Choroidal thickness measurement in children using optical coherence tomography
    Garnier, M. Bidaut
    Schwartz, C.
    Puyraveau, M.
    Montard, M.
    Delbosc, B.
    Saleh, M.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [8] CHOROIDAL THICKNESS MEASUREMENT IN CHILDREN USING OPTICAL COHERENCE TOMOGRAPHY
    Bidaut-Garnier, Melanie
    Schwartz, Claire
    Puyraveau, Marc
    Montard, Michel
    Delbosc, Bernard
    Saleh, Maher
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (04): : 768 - 774
  • [9] Contactless measurement of fabric thickness using optical coherence tomography
    Sabuncu, Metin
    Ozdemir, Hakan
    JOURNAL OF THE TEXTILE INSTITUTE, 2022, 113 (05) : 713 - 717
  • [10] Accuracy of measurement of stent strut thickness by optical coherence tomography
    Terashima, Mitsuyasu
    Nakayama, Yoshiaki
    Suzuki, Yasuyoshi
    Katoh, Osamu
    Suzuki, Takahiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B53 - B53