COVID-19 in cardiac arrest and infection risk to rescuers: A systematic review

被引:124
作者
Couper, Keith [1 ,2 ]
Taylor-Phillips, Sian [1 ]
Grove, Amy [1 ]
Freeman, Karoline [1 ]
Osokogu, Osemeke [1 ]
Court, Rachel [1 ]
Mehrabian, Amin [1 ,3 ]
Morley, Peter T. [4 ,5 ]
Nolan, Jerry P. [1 ,6 ]
Soar, Jasmeet [7 ]
Perkins, Gavin D. [1 ,2 ]
机构
[1] Univ Warwick, Warwick Med Sch, Coventry, W Midlands, England
[2] Univ Hosp Birmingham NHS Fdn Trust, Crit Care, Birmingham, W Midlands, England
[3] Mashhad Univ Med Sci, Sch Pharm, Dept Pharmaceut Nanotechnol, Mashhad, Razavi Khorasan, Iran
[4] Royal Melbourne Hosp, Intens Care, Melbourne, Vic, Australia
[5] Univ Melbourne, Fac Med Dent & Hlth Sci, Melbourne, Vic, Australia
[6] Royal United Hosp Bath NHS Fdn Trust, Intens Care Unit, Bath, Avon, England
[7] North Bristol NHS Trust, Southmead Hosp, Intens Care Unit, Bristol, Avon, England
基金
美国国家卫生研究院;
关键词
COVID-19; Coronavirus; Infection transmission; Aerosol; Personal protective equipment; Cardiopulmonary resuscitation; Chest compression; Defibrillation; CARDIOPULMONARY-RESUSCITATION; LIFE-SUPPORT; TRANSMISSION; SARS; VENTILATION; GUIDELINES; QUALITY;
D O I
10.1016/j.resuscitation.2020.04.022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: There may be a risk of COVID-19 transmission to rescuers delivering treatment for cardiac arrest. The aim of this review was to identify the potential risk of transmission associated with key interventions (chest compressions, defibrillation, cardiopulmonary resuscitation) to inform international treatment recommendations. Methods: We undertook a systematic review comprising three questions: (1) aerosol generation associated with key interventions; (2) risk of airborne infection transmission associated with key interventions; and (3) the effect of different personal protective equipment strategies. We searched MEDLINE, Embase, Cochrane Central Register of Controlled Trials, and the World Health Organization COVID-19 database on 24th March 2020. Eligibility criteria were developed individually for each question. We assessed risk of bias for individual studies, and used the GRADE process to assess evidence certainty by outcome. Results: We included eleven studies: two cohort studies, one case control study, five case reports, and three manikin randomised controlled trials. We did not find any direct evidence that chest compressions or defibrillation either are or are not associated with aerosol generation or transmission of infection. Data from manikin studies indicates that donning of personal protective equipment delays treatment delivery. Studies provided only indirect evidence, with no study describing patients with COVID-19. Evidence certainty was low or very low for all outcomes. Conclusion: It is uncertain whether chest compressions or defibrillation cause aerosol generation or transmission of COVID-19 to rescuers. There is very limited evidence and a rapid need for further studies.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 33 条
[1]   Using simulation for training and to change protocol during the outbreak of severe acute respiratory syndrome [J].
Abrahamson, Simon D. ;
Canzian, Sonya ;
Brunet, Fabrice .
CRITICAL CARE, 2006, 10 (01)
[2]  
Alhazzani W, 2020, INTENS CARE MED, DOI [10.1007/s00134-020-6022-5, DOI 10.1007/S00134-020-6022-5]
[3]   Presumed Asymptomatic Carrier Transmission of COVID-19 [J].
Bai, Yan ;
Yao, Lingsheng ;
Wei, Tao ;
Tian, Fei ;
Jin, Dong-Yan ;
Chen, Lijuan ;
Wang, Meiyun .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2020, 323 (14) :1406-1407
[4]   Transmission of Panton-Valentine leukocidin-producing Staphylococcus aureus to a physician during resuscitation of a child [J].
Chalumeau, M ;
Bidet, P ;
Lina, G ;
Mokhtari, M ;
André, MC ;
Gendrel, D ;
Bingen, E ;
Raymond, J .
CLINICAL INFECTIOUS DISEASES, 2005, 41 (03) :E29-E30
[5]   Delayed time to defibrillation after in-hospital cardiac arrest [J].
Chan, Paul S. ;
Krumholz, Harlan M. ;
Nichol, Graham ;
Nallamothu, Brahmajee K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (01) :9-17
[6]   Possible SARS coronavirus transmission during cardiopulmonary resuscitation [J].
Christian, MD ;
Loutfy, M ;
McDonald, C ;
Martinez, KF ;
Ofner, M ;
Wong, T ;
Wallington, T ;
Gold, WL ;
Mederski, B ;
Green, K ;
Low, DE .
EMERGING INFECTIOUS DISEASES, 2004, 10 (02) :287-293
[7]   Does compression-only cardiopulmonary resuscitation generate adequate passive ventilation during cardiac arrest? [J].
Deakin, Charles D. ;
O'Neill, John F. ;
Tabor, Ted .
RESUSCITATION, 2007, 75 (01) :53-59
[8]  
Guyatt GH, 2017, TOOL ASSESS RISK BIA
[9]  
Guyatt GH, 2011, J CLIN EPIDEMIOL, V64, P1311, DOI [10.1016/j.jclinepi.2011.06.004, 10.1016/j.jclinepi.2011.03.017]
[10]   The Cochrane Collaboration's tool for assessing risk of bias in randomised trials [J].
Higgins, Julian P. T. ;
Altman, Douglas G. ;
Gotzsche, Peter C. ;
Jueni, Peter ;
Moher, David ;
Oxman, Andrew D. ;
Savovic, Jelena ;
Schulz, Kenneth F. ;
Weeks, Laura ;
Sterne, Jonathan A. C. .
BMJ-BRITISH MEDICAL JOURNAL, 2011, 343