Electroactive Molecularly Imprinted Polymer Nanoparticles (eMIPs) for Label-free Detection of Glucose: Toward Wearable Monitoring

被引:8
作者
Garg, Saweta [1 ,2 ]
Singla, Pankaj [1 ,2 ]
Kaur, Sarbjeet [2 ,3 ]
Crapnell, Robert D. [4 ]
Banks, Craig E. [4 ]
Seyedin, Shayan [2 ]
Peeters, Marloes [1 ]
机构
[1] Univ Manchester, Dept Chem Engn, Engn Bldg,East Booth St,Oxford Rd, Manchester M13 9PL, England
[2] Newcastle Univ, Sch Engn, Newcastle Upon Tyne NE1 7RU, England
[3] Guru Nanak Dev Univ, Ctr Adv Studies, Dept Chem, Amritsar 143005, Punjab, India
[4] Manchester Metropolitan Univ, Fac Sci & Engn, Manchester M1 5GD, England
关键词
biosensors; conductive polymers; electroactive molecularly imprinted polymer nanoparticles (eMIPs); electrochemical sensors; glucose; polypyrrole (PPy); screen printed electrodes (SPEs); NONENZYMATIC ELECTROCHEMICAL GLUCOSE; DIABETES-MELLITUS; POROUS GOLD; BIOSENSOR; POLYPYRROLE; SENSORS;
D O I
10.1002/smll.202403320
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The diagnosis of diabetes mellitus (DM) affecting 537 million adults worldwide relies on invasive and costly enzymatic methods that have limited stability. Electroactive polypyrrole (PPy)-based molecularly imprinted polymer nanoparticles (eMIPs) have been developed that rival the affinity of enzymes whilst being low-cost, highly robust, and facile to produce. By drop-casting eMIPs onto low-cost disposable screen-printed electrodes (SPEs), sensors have been manufactured that can electrochemically detect glucose in a wide dynamic range (1 mu m-10 mm) with a limit of detection (LOD) of 26 nm. The eMIPs sensors exhibit no cross reactivity to similar compounds and negligible glucose binding to non-imprinted polymeric nanoparticles (eNIPs). Measurements of serum samples of diabetic patients demonstrate excellent correlation (>0.93) between these eMIPs sensor and the current gold standard Roche blood analyzer test. Finally, the eMIPs sensors are highly durable and reproducible (storage >12 months), showcasing excellent robustness and thermal and chemical stability. Proof-of-application is provided via measuring glucose using these eMIPs sensor in a two-electrode configuration in spiked artificial interstitial fluid (AISF), highlighting its potential for non-invasive wearable monitoring. Due to the versatility of the eMIPs that can be adapted to virtually any target, this platform technology holds high promise for sustainable healthcare applications via providing rapid detection, low-cost, and inherent robustness.
引用
收藏
页数:12
相关论文
共 80 条
[41]   Hydrogen bubble dynamic template synthesis of porous gold for nonenzymatic electrochemical detection of glucose [J].
Li, Ying ;
Song, Yan-Yan ;
Yang, Chen ;
Xia, Xing-Hua .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (05) :981-988
[42]   A novel non-enzymatic glucose sensor based on Cu nanoparticle modified graphene sheets electrode [J].
Luo, Jing ;
Jiang, Sisi ;
Zhang, Hongyan ;
Jiang, Jinqiang ;
Liu, Xiaoya .
ANALYTICA CHIMICA ACTA, 2012, 709 :47-53
[43]  
Mathew TK, 2023, Blood Glucose Monitoring
[44]   Molecularly Imprinted Polymer Nanoparticles Enable Rapid, Reliable, and Robust Point-of-Care Thermal Detection of SARS-CoV-2 [J].
McClements, Jake ;
Bar, Laure ;
Singla, Pankaj ;
Canfarotta, Francesco ;
Thomson, Alan ;
Czulak, Joanna ;
Johnson, Rhiannon E. ;
Crapnell, Robert D. ;
Banks, Craig E. ;
Payne, Brendan ;
Seyedin, Shayan ;
Losada-Perez, Patricia ;
Peeters, Marloes .
ACS SENSORS, 2022, 7 (04) :1122-1131
[45]   Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedlesis [J].
Miller, Philip R. ;
Taylor, Robert M. ;
Bao Quoc Tran ;
Boyd, Gabrielle ;
Glaros, Trevor ;
Chavez, Victor H. ;
Krishnakumar, Raga ;
Sinha, Anupama ;
Poorey, Kunal ;
Williams, Kelly P. ;
Branda, Steven S. ;
Baca, Justin T. ;
Polsky, Ronen .
COMMUNICATIONS BIOLOGY, 2018, 1
[46]   Finger-Stick Glucose Monitoring Issues of accuracy and specificity [J].
Olansky, Leann ;
Kennedy, Laurence .
DIABETES CARE, 2010, 33 (04) :948-949
[47]   Electrical properties and stability of polypyrrole containing conducting polymer composites [J].
Omastova, M ;
Kosina, S ;
Pionteck, J ;
Janke, A ;
Pavlinec, J .
SYNTHETIC METALS, 1996, 81 (01) :49-57
[48]   Electrochemical non-enzymatic glucose sensors [J].
Park, S ;
Boo, H ;
Chung, TD .
ANALYTICA CHIMICA ACTA, 2006, 556 (01) :46-57
[49]   Retinal neurodegeneration in patients with type 1 diabetes mellitus: the role of glycemic variability [J].
Picconi, Fabiana ;
Parravano, Mariacristina ;
Ylli, Dorina ;
Pasqualetti, Patrizio ;
Coluzzi, Sara ;
Giordani, Ilaria ;
Malandrucco, Ilaria ;
Lauro, Davide ;
Scarinci, Fabio ;
Giorno, Paola ;
Varano, Monica ;
Frontoni, Simona .
ACTA DIABETOLOGICA, 2017, 54 (05) :489-497
[50]  
Piletsky SA, 2002, ELECTROANAL, V14, P317, DOI 10.1002/1521-4109(200203)14:5<317::AID-ELAN317>3.3.CO