Additional multifocal sulcus-based intraocular lens: Alternative to multifocal intraocular lens in the capsular bag

被引:18
作者
Schrecker, Jens [1 ]
Kroeber, Sandra [1 ]
Eppig, Timo [2 ]
Langenbucher, Achim [2 ]
机构
[1] Klinikum Rudolf Virchow, Dept Ophthalmol, D-08371 Glauchau, Germany
[2] Univ Saarland, Homburg, Germany
关键词
ADD-ON IOL; PSEUDOPHAKIC EYES; CONTRAST SENSITIVITY; PUPIL SIZE; IMPLANTATION; ASTIGMATISM; ACUITY;
D O I
10.1016/j.jcrs.2012.10.047
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the visual outcomes of additional multifocal intraocular lenses (IOLs) for sulcus fixation with those of standard multifocal IOLs in the capsular bag. SETTING: Department of Ophthalmology, Rudolf-Virchow-Klinikum Glauchau, Glauchau, Germany. DESIGN: Prospective controlled clinical trial. METHODS: Eyes had phacoemulsification and implantation of a monofocal IOL in the capsular bag and an additional aberration-free diffractive IOL in the ciliary sulcus (multifocal add-on IOL group). Measurements of uncorrected and distance-corrected distance, intermediate, and near visual acuities; contrast sensitivity; and defocus curve were performed 3 months postoperatively. Results were compared with those in eyes with an aberration-correcting diffractive posterior chamber IOL (multifocal PC IOL group). RESULTS: The multifocal add-on IOL group comprised 34 eyes of 20 patients and the multifocal PC IOL group, 31 eyes of 17 patients. Cataract surgery, IOL implantation, and the postoperative course were uneventful in all cases. There were no statistically significant differences in uncorrected and distance-corrected distance, intermediate, or near visual acuities between the 2 groups. The median uncorrected distance visual acuity was 0.00 logMAR in both groups, and the median uncorrected near visual acuity was 0.10 logMAR in both groups. Contrast sensitivity testing yielded significantly better results in the multifocal add-on IOL group, especially at spatial frequencies over 1.5 cycles per degree. Defocus curves were similar in the 2 groups. CONCLUSION: Visual performance with a multifocal diffractive add-on IOL was equivalent to that achieved with a commonly used multifocal diffractive PC IOL.
引用
收藏
页码:548 / 555
页数:8
相关论文
共 15 条
  • [1] Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Baamonde, M. Begona
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) : 430 - 438
  • [2] Auffahrt GU, 2010, OPHTHALMOCHIRURGIE, V22, P265
  • [3] The use of a supplemental sulcus fixated IOL (HumanOptics Add-On IOL) to correct pseudophakic refractive errors
    Basarir, Berna
    Kaya, Vedat
    Altan, Cigdem
    Karakus, Sezen
    Pinarci, Eylem Y.
    Demirok, Ahmet
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (06) : 898 - 903
  • [4] Cochener B, 2011, CLIN OPHTHALMOL, V5, P45, DOI 10.2147/OPTH.S14325
  • [5] Long-term follow-up of a multifocal apodized diffractive intraocular lens after cataract surgery
    de Vries, Niels E.
    Webers, Carroll A. B.
    Montes-Mico, Robert
    Tahzib, Nayyirih G.
    Cheng, Yanny Y. Y.
    de Brabander, Johri
    Hendrikse, Fred
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) : 1476 - 1482
  • [6] Effect of corneal astigmatism on contrast sensitivity of mono- and multifocal pseudophakic eyes - A theoretical study with an optical system: Physical eyes
    Eisenmann, D
    Wagner, R
    Dick, B
    Jacobi, KW
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1996, 209 (2-3) : 125 - 131
  • [7] Dual intraocular lens implantation: Monofocal lens in the bag and additional diffractive multifocal lens in the sulcus
    Gerten, Georg
    Kermani, Omid
    Schmiedt, Karl
    Farvili, Elham
    Foerster, Andreas
    Oberheide, Uwe
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12) : 2136 - 2143
  • [8] New supplementary intraocular lens for refractive enhancement in pseudophakic patients
    Kahraman, Guenal
    Amon, Michael
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (07) : 1090 - 1094
  • [9] EFFECT OF PUPIL SIZE AND ASTIGMATISM ON CONTRAST ACUITY WITH MONOFOCAL AND BIFOCAL INTRAOCULAR LENSES
    KNORZ, MC
    KOCH, DD
    MARTINEZFRANCO, C
    LORGER, CV
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (01) : 26 - 33
  • [10] Pseudophakic supplementary intraocular lenses
    Kohnen, T.
    Klaproth, O. K.
    [J]. OPHTHALMOLOGE, 2010, 107 (08): : 766 - +