Dixon-based B0 self-navigation in radial stack-of-stars multi-echo gradient echo imaging

被引:0
作者
Stelter, Jonathan [1 ]
Weiss, Kilian [2 ]
Wu, Mingming [1 ,3 ]
Raspe, Johannes [1 ]
Braun, Philipp [1 ]
Zoellner, Christoph [1 ]
Karampinos, Dimitrios C. [1 ,4 ,5 ]
机构
[1] Tech Univ Munich, Inst Diagnost & Intervent Radiol, Sch Med & Hlth, Munich, Germany
[2] Philips GmbH Market DACH, Hamburg, Germany
[3] LMU Univ Hosp, Dept Radiol, Munich, Germany
[4] Tech Univ Munich, Munich Inst Biomed Engn, Garching, Germany
[5] Tech Univ Munich, Munich Data Sci Inst, Garching, Germany
关键词
B-0; drift; free-breathing; gradient echo imaging; T-2* mapping; water-fat separation; WATER-FAT SEPARATION; FIELD FLUCTUATIONS; ADIPOSE-TISSUE; H-1; MRS; QUANTIFICATION; THERMOMETRY; BREAST; QSM;
D O I
10.1002/mrm.30261
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a Dixon-based B-0 self-navigation approach to estimate and correct temporal B0 variations in radial stack-of-stars gradient echo imaging for quantitative body MRI. Methods: The proposed method estimates temporal B-0 variations using a B-0 self-navigator estimated by a graph-cut-based water-fat separation algorithm on the oversampled k-space center. The B-0 self-navigator was employed to correct for phase differences between radial spokes (one-dimensional [1D] correction) and to perform a motion-resolved reconstruction to correct spatiotemporal pseudo-periodic B-0 variations (three-dimensional [3D] correction). Numerical simulations, phantom experiments and in vivo neck scans were performed to evaluate the effects of temporal B-0 variations on the field-map, proton density fat fraction (PDFF) and T-2(& lowast;) map, and to validate the proposed method. Results: Temporal B-0 variations were found to cause signal loss and phase shifts on the multi-echo images that lead to an underestimation of T-2(& lowast;), while PDFF mapping was less affected. The B-0 self-navigator captured slowly varying temporal B-0 drifts and temporal variations caused by respiratory motion. While the 1D correction effectively corrected B-0 drifts in phantom studies, it was insufficient in vivo due to 3D spatially varying temporal B-0 variations with amplitudes of up to 25 Hz at 3 T near the lungs. The proposed 3D correction locally improved the correction of field-map and T-2(& lowast;) and reduced image artifacts. Conclusion: Temporal B-0 variations particularly affect T-2(& lowast;) mapping in radial stack-of-stars imaging. The self-navigation approach can be applied without modifying the MR acquisition to correct for B-0 drift and physiological motion-induced B-0 variations, especially in the presence of fat.
引用
收藏
页码:80 / 95
页数:16
相关论文
共 9 条
  • [1] Correcting gradient chain induced fat quantification errors in radial multi-echo Dixon imaging using a gradient modulation transfer function
    Zoellner, Christoph
    Kronthaler, Sophia
    Weiss, Kilian
    Boehm, Christof
    Stelter, Jonathan
    Rahmer, Juergen
    Boernert, Peter
    Peeters, Johannes M.
    Junker, Daniela
    Karampinos, Dimitrios C.
    FRONTIERS IN PHYSICS, 2023, 11
  • [2] Free-breathing radial stack-of-stars three-dimensional Dixon gradient echo sequence in abdominal magnetic resonance imaging in sedated pediatric patients
    Duffy, Patrick B.
    Stemmer, Alto
    Callahan, Michael J.
    Cravero, Joseph P.
    Johnston, Patrick R.
    Warfield, Simon K.
    Bixby, Sarah D.
    PEDIATRIC RADIOLOGY, 2021, 51 (09) : 1645 - 1653
  • [3] Free-breathing radial stack-of-stars three-dimensional Dixon gradient echo sequence in abdominal magnetic resonance imaging in sedated pediatric patients
    Patrick B. Duffy
    Alto Stemmer
    Michael J. Callahan
    Joseph P. Cravero
    Patrick R. Johnston
    Simon K. Warfield
    Sarah D. Bixby
    Pediatric Radiology, 2021, 51 : 1645 - 1653
  • [4] Single multi-echo GRE acquisition with short and long echo spacing for simultaneous quantitative mapping of fat fraction, B0 inhomogeneity, and susceptibility
    Liu, Junmin
    Christiansen, Spencer D.
    Drangova, Maria
    NEUROIMAGE, 2018, 172 : 703 - 717
  • [5] Free-Breathing Liver Fat, R2* and B0 Field Mapping Using Multi-Echo Radial FLASH and Regularized Model-Based Reconstruction
    Tan, Zhengguo
    Unterberg-Buchwald, Christina
    Blumenthal, Moritz
    Scholand, Nick
    Schaten, Philip
    Holme, Christian
    Wang, Xiaoqing
    Raddatz, Dirk
    Uecker, Martin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (05) : 1374 - 1387
  • [6] Free-breathing fat and R2* quantification in the liver using a stack-of-stars multi-echo acquisition with respiratory-resolved model-based reconstruction
    Schneider, Manuel
    Benkert, Thomas
    Solomon, Eddy
    Nickel, Dominik
    Fenchel, Matthias
    Kiefer, Berthold
    Maier, Andreas
    Chandarana, Hersh
    Block, Kai Tobias
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2592 - 2605
  • [7] Spatially resolved free-induction decay spectroscopy using a 3D ultra-short echo time multi-echo imaging sequence with systematic echo shifting and compensation of B0 field drifts
    Fischer, Anja
    Martirosian, Petros
    Benkert, Thomas
    Schick, Fritz
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2099 - 2110
  • [8] Dynamic water/fat separation and B0 inhomogeneity mapping-joint estimation using undersampled triple-echo multi-spoke radial FLASH
    Tan, Zhengguo
    Voit, Dirk
    Kollmeier, Jost M.
    Uecker, Martin
    Frahm, Jens
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (03) : 1000 - 1011
  • [9] Liver Lobe Based Multi-Echo Gradient Recalled Echo T2*-Weighted Imaging in Chronic Hepatitis B-Related Cirrhosis: Association with the Presence and Child-Pugh Class of Cirrhosis
    Wang, Dan
    Chen, Tian-wu
    Zhang, Xiao-ming
    Li, Jie
    Zeng, Nan-lin
    Li, Li
    Tang, Yu-lian
    Huang, Yu-cheng
    Li, Rui
    Chen, Fan
    Chen, Yan-li
    PLOS ONE, 2016, 11 (05):